EPA Tier 2 covered most engines manufactured 2003–2010 and remains the dominant tier in the installed base of pre-T4F industrial gensets. Tier 2 units have no DPF or SCR — operations are simpler, but emissions and PM output are higher. Many municipalities allow continued operation of legacy Tier 2 emergency-standby units indefinitely; some jurisdictions (notably parts of California) have begun retire-or-retrofit programs.
123 models in this category.
Need help selecting a epa tier 2 diesel generators?
Our application engineers help size, spec, and source backup power for commercial, industrial, and mission-critical sites.
Open Basler controller + Mitsubishi V12 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component independence matter.
1000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12H-Y2PTAW-1 37.1L V12 engine, Stamford S6L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD1250-01
Open Basler controller + Mitsubishi V12 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for industrial, data center, and utility-scale applications where value engineering and open-architecture components matter.
1250 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12R-Y2PTAW-1 49.0L V12 engine, Stamford S6L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD1600-01
Open Basler controller + Mitsubishi V16 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW diesel standby for industrial, data center, and utility-scale applications where value engineering and non-proprietary components matter.
1600 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S16R-Y2PTAW-1 65.4L V16 engine, Stamford S7L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD2000-01
Open Basler controller + Mitsubishi V16 engine + Stamford alternator — no proprietary lock-in. 2 MW class without OEM dealer dependency.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for data centers, hospitals, and utility-scale applications where component independence and value engineering matter.
2000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S16R-Y2PTAW2-1 65.4L V16 engine, Stamford S7L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star MD800-01
Open Basler controller + Mitsubishi V12 engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for industrial plants, campus power, and data centers where value engineering and non-proprietary component access matter.
800 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12A2-Y2PTAW-2 33.9L V12 engine, Stamford S6L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.
Tier 23-phaseindustrialmunicipal
Blue Star Power Systems
Blue Star PD500-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for industrial, data center, and campus facilities where value engineering and non-proprietary component access matter.
500 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2506C-E15TAG3 six-cylinder engine with charge air cooling, Stamford HCI534D alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD550-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for industrial, data center, and campus facilities where value engineering and open-architecture components matter.
550 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2506C-E15TAG4 six-cylinder engine with charge air cooling, Stamford HCI534E alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD600-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2806C-E18TAG3 six-cylinder engine with charge air cooling, Stamford HCI534E alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star PD750-01
Open Basler controller + Perkins engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
750 kW standby · Diesel · Liquid-cooled
750 kW diesel standby for industrial, data center, and mission-critical facilities where value engineering and non-proprietary components matter.
750 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2806C-E18TTAG7 twin-turbocharged six-cylinder engine, Stamford S6L1D-C alternator, DSE DCP7310 controller.
Tier 23-phasecommercialindustrial
Blue Star Power Systems
Blue Star VD500-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for industrial, data center, and campus facilities where value engineering and non-proprietary component access matter.
500 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1641GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD550-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for industrial, data center, and campus facilities where value engineering and open-architecture components matter.
550 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1642GE-B 16.1L inline-six with DSE DCP7310 controller, 208-600V output.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD600-01
Open Basler DGC-2020 controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW EPA Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1643GE 16.1L inline-six, 208-4160V output, available with medium-voltage option.
Tier 23-phaselarge-commercialhospital
Blue Star Power Systems
Blue Star VD600-03
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. Serviceable by any qualified tech, not just the dealer.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for industrial, data center, and campus power where value engineering and non-proprietary component access matter.
600 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1644GE 16.1L inline-six with dual-stage turbo, DSE DCP7310 controller, 208-600V.
Tier 23-phasecommerciallarge-commercial
Blue Star Power Systems
Blue Star VD700-01
Open Basler controller + Volvo Penta engine + Stamford alternator — no proprietary lock-in. 700 kW class without OEM dealer dependency.
700 kW standby · Diesel · Liquid-cooled
700 kW diesel standby for industrial, data center, and mission-critical facilities where value engineering and non-proprietary components matter.
700 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TWD1744GE 17.3L inline-six with Common Rail injection, DSE DCP7310 controller, 208-600V.
Tier 23-phaselarge-commercialhospital
Caterpillar
Cat 3516C
2500 kW diesel with CAT 3516C V-16. EPA Tier 4 Final. Best resale in class. Paralleling for multi-MW arrays.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW diesel standby for hyperscale data centers, campus microgrids, and emission-regulated industrial.
2500 kW diesel standby generator with Cat 3516C V-16 engine. The largest Cat genset platform for mission-critical data centers and industrial power.
Tier 23-phasedata-centerhospital-large
Caterpillar
Cat 3516E
3000 kW diesel with CAT 3516E V-16. Best resale value in class. Paralleling for multi-MW. ~200 US dealers.
3 MW standby · Diesel · Liquid-cooled
3000 kW diesel standby for hyperscale data centers, campus microgrids, and utility peak shaving.
Up to 3000 kW diesel generator with Cat 3516E V-16 engine. 78.1L displacement, Tier 2 equivalent, ATAAC aspiration for standby and mission-critical power.
Tier 23-phasecommercial-standbymission-critical
Caterpillar
Cat C15
500 kW diesel with CAT C15 ACERT inline-6. Best resale value in class. ~200 US dealers with deep parts inventory.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for hospitals, data centers, and large commercial with CAT fleet standardization.
500 kW diesel standby generator with Cat C15 ACERT engine. Large commercial standby for hospitals, high-rises, and municipal infrastructure.
Tier 23-phasehospitalhigh-rise
Caterpillar
Cat C175-16
3100 kW diesel with CAT C175-16 V-16. Medium-voltage capable (4160V/13.8kV). Best resale. Paralleling for multi-MW.
3.1 MW standby · Diesel · Liquid-cooled
3100 kW diesel standby for hyperscale data centers, campus microgrids, and mission-critical infrastructure.
2500-3100 kW diesel generator with Cat C175-16 SCAC V-16 engine. 84.7L displacement, Tier 2, mission-critical and standby power for data centers and large industrial facilities.
Tier 23-phasecommercial-standbymission-critical
Caterpillar
Cat C27
800 kW diesel with CAT C27 V-12. Best resale -- retains 15-25% more than competitors. Paralleling-ready.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
1500 kW diesel with CAT 3512C V-12. EPA Tier 4 Final. Best resale value in class. ~200 US dealers.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier III+ data centers, hospitals, and emission-sensitive industrial sites.
The Caterpillar 3512C is a 1500 kW standby diesel generator. 51.8L V12 ATAAC, 14.7:1 compression, EPA Tier 2. Fuel: 104.6 gal/hr at full load. Medium-voltage outputs to 13,800V for mission-critical applications.
Tier 23-phasedata-centerhospital-large
Caterpillar
Caterpillar C18
600 kW diesel with CAT C18 ACERT inline-6. Best resale -- retains 15-25% more than Cummins/MTU. ~200 US dealers.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for large data centers, hospitals, and industrial plants with CAT fleet.
The Caterpillar C18 ACERT is a 600 kW standby diesel generator with EPA Tier 2 certification. 18.1L inline-6 with MEUI injection. Fuel: 42.7 gal/hr at full load. Supports 4160V medium-voltage for hospital and campus applications.
Tier 23-phasehospital-mediumcampus
Cummins
Cummins C1000 D6
1 MW diesel with QST30 V-12 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT.
1 MW standby · Diesel · Liquid-cooled
1000 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure requiring megawatt-class power.
1000 kW diesel standby generator with QST30 30L V-12 engine. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications requiring megawatt-class power.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1100 D6
1100 kW diesel with QSK38 V-12 engine. MCRS fuel injection. Full Cummins vertical integration. Paralleling for multi-MW.
1.1 MW standby · Diesel · Liquid-cooled
1100 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure requiring above-megawatt power.
1100 kW diesel standby generator with QSK38 37.7L V-12 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1250 D6
1250 kW diesel with QSK38 V-12 engine at full rated output. MCRS fuel injection. Full Cummins vertical integration. Paralleling for multi-MW.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure.
1250 kW diesel standby generator with QSK38 37.7L V-12 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, 2P2L cooling, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1250 D6e
1.25 MW Centum Series with QSK38 engine. Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins premium platform.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW Centum diesel standby for data centers, hospitals, and mission-critical facilities requiring premium reliability with reduced footprint.
1250 kW Centum Series diesel standby generator with QSK38 engine. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center and mission-critical applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1500 D6
1500 kW diesel with QSK50 V-16 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3512.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier IV data centers, university campuses, and major industrial plants requiring maximum single-unit power.
1500 kW diesel standby generator with QSK50 50.3L V-16 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, 2P2L cooling, for data center, hospital, and mission-critical standby applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1500 D6e
1.5 MW Centum Series with QSK38 at peak output. Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins platform.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW Centum diesel standby for data centers, hospitals, and mission-critical facilities requiring premium reliability with reduced footprint.
1500 kW Centum Series diesel standby generator with QSK38 engine. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center and mission-critical applications.
Tier 23-phasedata-centerhospital
Cummins
Cummins C1750 D6e
1.75 MW Centum Series with QSK50 engine (launched 2024). Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins platform.
1.8 MW standby · Diesel · Liquid-cooled
1750 kW Centum diesel standby for data centers and mission-critical facilities requiring premium reliability with reduced footprint.
1750 kW Centum Series diesel standby generator with QSK50 engine, launched 2024. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C2000 D6
2 MW diesel with QSK60 V-16 engine. Full Cummins vertical integration. Paralleling for multi-MW arrays. Proven mega-diesel platform.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for Tier III/IV data centers, large industrial facilities, and mission-critical infrastructure requiring multi-megawatt power.
2000 kW diesel standby generator with QSK60 60L V-16 engine. PowerCommand control, liquid-cooled, for data center, industrial, and mission-critical standby applications requiring multi-megawatt power.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C2000 D6e
2 MW Centum Series with QSK50 engine (launched 2024). Smaller footprint, PowerCommand 3.3, charged air-cooled intake. Single-source Cummins platform.
2 MW standby · Diesel · Liquid-cooled
2000 kW Centum diesel standby for data centers and mission-critical facilities requiring 2 MW premium standby power with reduced footprint.
2000 kW Centum Series diesel standby generator with QSK50 engine, launched 2024. PowerCommand 3.3 controller, charged air-cooled intake, smaller footprint, single-source Cummins integration for data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C2000D5
2 MW standby · Diesel · Liquid-cooled
Cummins C2000D5: 2000 kW industrial standby diesel generator powered by the QSK60-G23 engine. Three-phase 277/480V for large data centers and mission-critical infrastructure.
Tier 23-phaseindustrialdata-center
Cummins
Cummins C2250 D6
2.25 MW diesel with QSK60 V-16 engine. Mid-range of the QSK60 platform. Full Cummins vertical integration. Paralleling for multi-MW arrays.
2.3 MW standby · Diesel · Liquid-cooled
2250 kW diesel standby for Tier III/IV data centers, large industrial facilities, and mission-critical infrastructure.
2250 kW diesel standby generator with QSK60 60L V-16 engine. PowerCommand control, liquid-cooled, for data center, industrial, and mission-critical standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C2500 D6
2.5 MW diesel with QSK60 V-16 engine at peak output. Full Cummins vertical integration. Maximum QSK60 platform capacity in a single genset.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW diesel standby for Tier III/IV data centers, large industrial plants, and mission-critical infrastructure requiring maximum QSK60 output.
2500 kW diesel standby generator with QSK60 60L V-16 engine. PowerCommand control, liquid-cooled, top of the QSK60 platform for data center and mission-critical standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C2750 D6e
2.75 MW Centum Series with QSK78-G36 engine (launched 2024). Smaller footprint than traditional mega-diesels. PowerCommand 3.3 for hyperscale arrays.
2.8 MW standby · Diesel · Liquid-cooled
2750 kW Centum diesel standby for hyperscale data centers and mission-critical facilities requiring near-3 MW premium standby power.
2750 kW Centum Series diesel standby generator with QSK78-G36 engine, launched 2024. PowerCommand 3.3 controller, charged air-cooled intake, single-source Cummins integration for hyperscale data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C3000 D6
3 MW diesel with QSK95-G2 V-16 engine. Cummins' largest displacement platform. Full vertical integration. Paralleling for 6-30 MW arrays.
3 MW standby · Diesel · Liquid-cooled
3000 kW diesel standby for hyperscale data centers, large industrial complexes, and utility-scale mission-critical infrastructure.
3000 kW diesel standby generator with QSK95-G2 95L V-16 engine. PowerCommand control, liquid-cooled, for data center, utility, and mission-critical standby applications requiring 3 MW single-engine power.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C3000 D6eb
3 MW Centum Series flagship with QSK78-G37 engine. Smaller footprint than QSK95-based alternatives. PowerCommand 3.3, charged air-cooled intake.
3 MW standby · Diesel · Liquid-cooled
3000 kW Centum diesel standby for hyperscale data centers and mission-critical facilities requiring 3 MW premium standby power in a compact platform.
3000 kW Centum Series diesel standby generator with QSK78-G37 engine. PowerCommand 3.3 controller, charged air-cooled intake, single-source Cummins integration, the flagship Centum genset for hyperscale data center applications.
Tier 23-phasedata-centermission-critical
Cummins
Cummins C3250 D6
3.25 MW diesel with QSK95-G2 V-16. Mid-range of the QSK95 platform. Full Cummins vertical integration for hyperscale standby arrays.
3.3 MW standby · Diesel · Liquid-cooled
3250 kW diesel standby for hyperscale data centers, large industrial complexes, and mission-critical infrastructure.
3250 kW diesel standby generator with QSK95-G2 95L V-16 engine. PowerCommand control, liquid-cooled, for hyperscale data center and mission-critical standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C3500 D6
3.5 MW diesel with QSK95-G2 V-16 at peak output. Cummins' largest single-engine D6 genset. Full vertical integration for hyperscale standby arrays.
3.5 MW standby · Diesel · Liquid-cooled
3500 kW diesel standby for hyperscale data centers, utility-scale standby, and the largest single-engine mission-critical applications.
3500 kW diesel standby generator with QSK95-G2 95L V-16 engine. PowerCommand control, liquid-cooled, the largest D6 Commercial Diesel genset for hyperscale data center and utility standby applications.
Tier 23-phasedata-centerindustrial
Cummins
Cummins C450 D6
450 kW diesel with QSX15 DOHC engine. 30% fewer parts than comparable platforms. Full Cummins vertical integration.
450 kW standby · Diesel · Liquid-cooled
450 kW diesel standby for large hospitals, industrial plants, and data centers requiring high reliability.
450 kW diesel standby generator with QSX15 inline-6 DOHC engine. EPA NSPS certified, PowerCommand control, liquid-cooled, for large commercial and industrial standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C500 D6
500 kW diesel with QSX15 DOHC engine. 30% fewer parts than comparable platforms. Full Cummins vertical integration.
500 kW standby · Diesel · Liquid-cooled
500 kW diesel standby for Tier III data centers, major hospitals, and large industrial facilities.
500 kW diesel standby generator with QSX15 inline-6 DOHC engine. EPA NSPS certified, PowerCommand control, liquid-cooled, for large commercial, industrial, and data center standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C600 D6
600 kW diesel with QSK19 engine. Full Cummins vertical integration. MCRS fuel system for lower emissions and fuel consumption.
600 kW standby · Diesel · Liquid-cooled
600 kW diesel standby for large hospitals, data centers, and heavy industrial plants with critical power requirements.
600 kW diesel standby generator with QSK19 19L inline-6 engine and MCRS fuel injection. EPA Tier 2 compliant, PowerCommand control, liquid-cooled, for large commercial, industrial, and data center standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C750 D6
750 kW diesel with QSK23 engine. Full Cummins vertical integration. 100% load in 10 seconds. Paralleling capable.
750 kW standby · Diesel · Liquid-cooled
750 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
750 kW diesel standby generator with QSK23-G3 23.1L inline-6 engine and HPI-PT fuel injection. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C750D5
750 kW standby · Diesel · Liquid-cooled
Cummins C750D5: 750 kW industrial standby diesel generator powered by the QSK23-G3 engine. Three-phase 277/480V for data centers, hospitals, and critical infrastructure.
Tier 23-phaseindustrialdata-center
Cummins
Cummins C800 D6
800 kW diesel with QSK23 engine. Full Cummins vertical integration. 100% load in 10 seconds. Paralleling for multi-MW.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses requiring N+1 redundancy.
800 kW diesel standby generator with QSK23-G3 23.1L inline-6 engine and HPI-PT fuel injection. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins C900 D6
900 kW diesel with QST30 V-12 engine. Full Cummins vertical integration. 100% load in 10 seconds. Paralleling for multi-MW.
900 kW standby · Diesel · Liquid-cooled
900 kW diesel standby for Tier III+ data centers, large hospitals, and mission-critical infrastructure.
900 kW diesel standby generator with QST30-G3 30L V-12 engine. PowerCommand control, liquid-cooled, for data center, hospital, and mission-critical standby applications.
Tier 23-phasecommercial-standbylarge-commercial
Cummins
Cummins QSK19
550 kW diesel with QSK19 engine. Full Cummins vertical integration. Power Command controller. 10-15% below CAT.
550 kW standby · Diesel · Liquid-cooled
550 kW diesel standby for large data centers, hospitals, and heavy industrial plants.
550 kW standby / 500 kW prime diesel generator with QSK19-G4 19L inline-6 MCRS engine. EPA Tier 2, CTT HX83 turbocharging, 24V starting. Engine dimensions 1695 x 985 x 1723 mm, dry weight 1900 kg.
Tier 23-phasehospital-mediumcampus
Cummins
Cummins QSK23
800 kW diesel with QSK23 engine. Full Cummins vertical integration. 100% load in 10 seconds. 10-15% below CAT.
800 kW standby · Diesel · Liquid-cooled
800 kW diesel standby for mission-critical data centers, large hospitals, and industrial campuses.
800 kW standby / 727 kW prime diesel generator with QSK23-G3 23.1L inline-6 HPI-PT engine. Non-regulated, CTT HX82 turbocharging, 24V starting. Engine dimensions 2976 x 1656 x 1964 mm, dry weight 3245 kg.
Tier 23-phasehospital-largecampus
Cummins
Cummins QSK38
1160 kW diesel with QSK38 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT.
1.2 MW standby · Diesel · Liquid-cooled
1160 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure.
1160 kW standby / 965 kW prime diesel generator with QSK38-G5 37.7L V12 MCRS engine. EPA Tier 2, 2P2L cooling, 24V starting. Engine dimensions 2081 x 1492 x 1860 mm, dry weight 4100 kg.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK50
1500 kW diesel with QSK50 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3512.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW diesel standby for Tier IV data centers, university campuses, and major industrial plants.
1500 kW standby / 1365 kW prime diesel generator with QSK50-G4 50.3L V16 MCRS engine. EPA Tier 2 and TA Luft compliant, 2P2L cooling, 24V starting. Engine dimensions 4674 x 2468 x 3100 mm, dry weight 7429 kg.
Tier 23-phasedata-centerhospital-large
Cummins
Cummins QSK60
2000 kW diesel with QSK60 engine. Full Cummins vertical integration. Paralleling for multi-MW. 10-15% below CAT 3516.
2 MW standby · Diesel · Liquid-cooled
2000 kW diesel standby for hyperscale data centers, large hospitals, and campus microgrids.
2000 kW diesel standby generator. The data center industry standard — V-16, 60.2L, Tier 2. Cummins' flagship for mission-critical power.
Tier 23-phasedata-centerhospital
Cummins
Cummins QSK95
3010 kW diesel with QSK95 engine -- Cummins largest. Full vertical integration. Paralleling for campus-scale power.
3.0 MW standby · Diesel · Liquid-cooled
3010 kW diesel standby for hyperscale data centers, campus microgrids, and utility peak shaving.
3010 kW standby / 2690 kW prime diesel generator with QSK95-G10 V16 engine. EPA Tier 2, quad turbo, MCRS fuel injection, ISO 8528-G3 transient capability.
Tier 23-phasedata-centerhospital
Doosan / Bobcat
Doosan G450
Legacy Tier 2 with no DPF, no SCR, no DEF — the simplest large-frame maintenance in the lineup. Cummins QSX15 proven reliability at value-tier pricing.
400 kW standby · Diesel · Liquid-cooled
Large construction sites in Tier 2-permissible jurisdictions, mining operations, industrial standby, and rental fleet legacy units still in active service.
375 kW prime diesel portable generator. Cummins QSX15-powered large-frame unit with 574-gallon tank. Legacy Tier 2 model.
Tier 23-phaseconstructionrental-fleet
Generac
Generac MD1250
1250 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture for multi-megawatt systems.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW modular diesel for Tier III+ data centers, large hospitals, and mission-critical facilities requiring redundancy.
1250 kW modular diesel standby generator system. Factory-paralleled configuration with Mitsubishi 49.0L V12 engine for N+1 redundancy.
Tier 23-phasecommercial-standbyindustrial
Generac
Generac MD1500
1500 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture for multi-megawatt systems.
1.5 MW standby · Diesel · Liquid-cooled
1500 kW modular diesel for Tier IV data centers, university campuses, and mission-critical facilities requiring redundancy.
1500 kW modular diesel standby generator system. Factory-paralleled configuration with Mitsubishi 65.4L V16 engine for N+1 redundancy.
Tier 23-phasecommercial-standbyindustrial
Generac
Generac MD750
750 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture.
750 kW standby · Diesel · Liquid-cooled
750 kW modular diesel for data centers, hospitals, and mission-critical facilities requiring redundancy and serviceability.
750 kW modular diesel standby generator system. Factory-paralleled configuration with Mitsubishi S12A2-Y2PTAW-2 33.9L V12 engine for N+1 redundancy.
Tier 23-phasecommercial-standbyindustrial
Generac
Generac SD1250
1250 kW industrial diesel with Mitsubishi engine. Competitive pricing vs CAT/Cummins. Paralleling for multi-MW systems.
1.3 MW standby · Diesel · Liquid-cooled
1250 kW diesel standby for Tier III+ data centers, large hospitals, and critical infrastructure.
First MW-class unit in the HMW lineup — MTU 16V2000 32L 16-cylinder with 30,000-hour TBO. Standard for hyperscale data center 1 MW bus design.
1 MW standby · Diesel · Liquid-cooled
1 MW+ critical standby for hyperscale data center 1 MW bus rows, large hospital main plants, and mission-critical industrial utility in NFPA 110 Level 1 applications.
1020 kW MTU 2000-series diesel generator. Exceeds 1 MW standby. NFPA 110 Level 1, seismic certified. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1205
MTU 16V2000 at 1,205 kW — top of the 2000 series before entering the 4000 series. Maximum output for a single 16V2000 unit with 30,000-hour TBO.
1.2 MW standby · Diesel · Liquid-cooled
1.2 MW single-unit critical standby for hyperscale data center rows, large hospital main plants, and transmission-level utility backup.
1205 kW MTU 2000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1550
MTU 4000 series — the industrial benchmark for 1.5 MW+ standby. 52L 12-cylinder V with 30,000-hour TBO. Used in defense, hyperscale, and utility generation.
1.5 MW standby · Diesel · Liquid-cooled
1.5 MW critical standby for hyperscale data centers, major hospital campuses, military installations, and electric utility backup in NFPA 110 Level 1 applications.
1550 kW MTU 4000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1730
MTU 12V4000 at 1.7 MW — maximum output for the 12-cylinder 4000 series. 30,000-hour TBO at 1.7 MW single-unit standby.
1.7 MW standby · Diesel · Liquid-cooled
1.7 MW critical standby for hyperscale data centers, military bases, and large hospital campuses requiring NFPA 110 Level 1 with .
1730 kW MTU 4000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-1975
MTU 16V4000 near-2 MW — 68L 16-cylinder V with 30,000-hour TBO. The largest single-unit generator class deployed at hyperscale cloud data centers.
2.0 MW standby · Diesel · Liquid-cooled
Near-2 MW critical standby for hyperscale data centers, transmission substations, military bases, and large campus essential systems.
1975 kW MTU 4000-series diesel generator. Near-2 MW single unit. NFPA 110 Level 1, seismic certified. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-2230
The largest HMW model — MTU 16V4000 at 2.2 MW. 68L 16-cylinder V, 30,000-hour TBO. The maximum single-unit diesel generator for hyperscale data centers.
2.2 MW standby · Diesel · Liquid-cooled
2+ MW critical standby for hyperscale data centers, utility substations, military base power, and large campus essential electrical systems.
2230 kW MTU 4000-series diesel generator. 2.2 MW single unit. NFPA 110 Level 1, seismic certified. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-510
MTU 16V1600 — 16-cylinder V-engine at 500+ kW with the same 30,000-hour TBO as smaller HMW models. Caterpillar 3512 competitor at lower lifecycle cost.
500 kW standby · Diesel · Liquid-cooled
500 kW-class mission-critical standby for large data centers, trauma centers, and industrial utility applications requiring NFPA 110 Level 1.
510 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-615
MTU 16V1600 at 600+ kW — top of the 1600 series with 30,000-hour TBO. The benchmark for single-unit 600 kW critical standby.
600 kW standby · Diesel · Liquid-cooled
600 kW-class single-unit critical standby for hyperscale data center pods, large hospital campuses, and utility generation in seismic and CARB regions.
615 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-810
MTU 2000 series enters at 810 kW — 24L 12-cylinder V-engine with 30,000-hour TBO. The engine choice of Tier I hyperscale data centers globally.
800 kW standby · Diesel · Liquid-cooled
800 kW-class critical standby for hyperscale data center rows, large hospital campuses, and electric utility installations requiring NFPA 110 Level 1 in seismic and CARB regions.
810 kW MTU 2000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HMW-915
MTU 12V2000 at near-MW output — 30,000-hour TBO, single-unit 900 kW standby with NFPA 110 Level 1, seismic, and CARB compliance in one package.
900 kW standby · Diesel · Liquid-cooled
Near-MW critical standby for hyperscale data center rows, large hospital campuses, and industrial utilities needing single-unit 900 kW coverage.
915 kW MTU 2000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.
Tier 23-phaseindustrial-standbydata-center
Hipower Systems
Hipower HRMW-1150
920 kW on a towable trailer — MTU 16V2000 power with the mobility for data center commissioning, disaster recovery, and utility substation backup.
920 kW standby · Diesel · Liquid-cooled
Temporary 1 MW+ power for data center commissioning, disaster recovery bridge power, utility substation backup, and large construction projects requiring tow-in generation.
1150 kW trailer-mounted MTU diesel generator. Rental-ready for data center commissioning and disaster recovery. Built in Olathe, Kansas.
Tier 23-phaserental-fleetdata-center
Kohler
Kohler 1250REOZMD
1280 kW diesel standby -- Mitsubishi S12R-Y2PTAW-1, sub-3% THD. Decision-Maker controller for load management and paralleling.
1.3 MW standby · Diesel · Liquid-cooled
1280 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
1280 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 1600REOZMD
1600 kW industrial diesel -- Mitsubishi S16R-Y2PTAW-1 with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
1.6 MW standby · Diesel · Liquid-cooled
1600 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1600 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 1750REOZMD
1780 kW industrial diesel -- Mitsubishi S16R-Y2PTAW2-1 with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
1.8 MW standby · Diesel · Liquid-cooled
1780 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
1780 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 2000REOZMD
2000 kW industrial diesel -- Mitsubishi S16R-Y2PTAW2-1 with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
2 MW standby · Diesel · Liquid-cooled
2000 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
2000 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 2500REOZDC
2500 kW industrial diesel -- Detroit Diesel/MTU 16V4000G83L with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and utility-scale facilities. Parallel-ready for N+1 mission-critical redundancy.
2500 kW diesel industrial generator powered by Detroit Diesel/MTU. Mission-critical standby for data centers, hospitals, and large commercial facilities.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler 500REOZJ
500 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Decision-Maker controller for load management and paralleling.
500 kW standby · Diesel · Liquid-cooled
500 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
500 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 500REOZJB
510 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Decision-Maker controller for load management and paralleling.
510 kW standby · Diesel · Liquid-cooled
510 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
510 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 500REOZJC
500 kW diesel standby -- John Deere 6135HFG75, sub-3% THD. Decision-Maker controller for load management and paralleling.
500 kW standby · Diesel · Liquid-cooled
500 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
500 kW diesel commercial standby generator. Large institutional diesel for hospitals, data centers, high-rises, and mission-critical facilities.
Tier 23-phasehospitaldata-center
Kohler
Kohler 500REOZVC
515 kW diesel standby -- Volvo TAD1641GE-B, sub-3% THD. Decision-Maker controller for load management and paralleling.
515 kW standby · Diesel · Liquid-cooled
515 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
515 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 550REOZVB
550 kW diesel standby -- Volvo TAD1642GE-B, sub-3% THD. Decision-Maker controller for load management and paralleling.
550 kW standby · Diesel · Liquid-cooled
550 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
550 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 600REOZVB
600 kW diesel standby -- Volvo TWD1643GE, sub-3% THD. Decision-Maker controller for load management and paralleling.
600 kW standby · Diesel · Liquid-cooled
600 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
600 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler 750REOZMD
760 kW diesel standby -- Mitsubishi S12A2-Y2PTAW-2, sub-3% THD. Decision-Maker controller for load management and paralleling.
760 kW standby · Diesel · Liquid-cooled
760 kW commercial/industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
760 kW diesel commercial/industrial standby generator powered by Mitsubishi. Suitable for hospitals, data centers, and large commercial complexes.
Tier 23-phasecommercialhealthcare
Kohler
Kohler
Kohler 900REOZMD
900 kW diesel standby -- Mitsubishi S12H-Y2PTAW-1, sub-3% THD. Decision-Maker controller for load management and paralleling.
900 kW standby · Diesel · Liquid-cooled
900 kW industrial standby for hospitals, data centers, and large campuses requiring NFPA 110 Level 1.
900 kW diesel industrial standby generator powered by Mitsubishi. Large-frame REOZ for data centers, hospitals, and mission-critical facilities.
1750 kW industrial standby for data centers, hospitals, and large commercial campuses. NFPA 110 Level 1, UL 2200 listed.
1750 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2000
2000 kW KD Series -- Kohler KD62V12 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2 MW standby · Diesel · Liquid-cooled
2000 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2000 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure requiring multi-megawatt backup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2250
2250 kW KD Series -- Kohler KD62V12 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2.3 MW standby · Diesel · Liquid-cooled
2250 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2250 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical facilities approaching 2 MW.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2500
2500 kW KD Series -- Kohler KD62V12 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2.5 MW standby · Diesel · Liquid-cooled
2500 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2500 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and heavy industrial facilities requiring 2+ MW backup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD2800
2800 kW KD Series -- Kohler KD83V16 with sub-3% THD and PM pilot exciter. Hurricane-rated enclosures available.
2.8 MW standby · Diesel · Liquid-cooled
2800 kW industrial standby for data centers, hospitals, and critical infrastructure requiring multi-MW backup with NFPA 110 Level 1.
2800 kW diesel industrial standby generator. Upper-range KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD3000
3000 kW KD Series -- Kohler KD83V16 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
3 MW standby · Diesel · Liquid-cooled
3000 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
3000 kW diesel industrial standby generator. Upper-range KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD3250
3250 kW KD Series -- Kohler KD83V16 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
3.3 MW standby · Diesel · Liquid-cooled
3250 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
3250 kW diesel industrial standby generator. Upper-range KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD3500
3500 kW KD Series -- Kohler KD103V20 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
3.5 MW standby · Diesel · Liquid-cooled
3500 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
3500 kW diesel industrial standby generator. Near-top-of-line KD Series platform for data centers, healthcare, and mission-critical infrastructure.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD4000
4000 kW KD Series -- Kohler KD103V20 engine, skewed stator for sub-3% THD. Purpose-built for multi-MW mission-critical paralleling.
4 MW standby · Diesel · Liquid-cooled
4000 kW industrial standby for Tier IV data centers, large hospitals, and campus microgrids. NFPA 110 Level 1, UL 2200 listed.
4000 kW diesel industrial standby generator. Flagship KD Series platform — the largest single-engine generator in Kohler's industrial lineup.
Tier 23-phasedata-centerhealthcare
Kohler
Kohler KD900
900 kW KD Series -- Kohler KD27V12 with sub-3% THD and PM pilot exciter. Clean power for sensitive loads.
900 kW standby · Diesel · Liquid-cooled
900 kW industrial standby for data centers, hospitals, and mission-critical facilities requiring premium power quality and NFPA 110 Level 1.
900 kW diesel industrial standby generator. Entry-level KD Series platform for data centers, healthcare, and mission-critical facilities.
Tier 23-phasedata-centerhealthcare
MTU
MTU 12V1600 DS750
750 kW diesel standby — 12V1600 sweet spot. Same footprint as DS600/DS900, 50°C radiator, 51 gph, Leroy-Somer alternator.
750 kW standby · Diesel · Liquid-cooled
Healthcare/data center/high-rise standby at 750 kW. Diesel at 51 gph, compact for sub-MW class, SCAQMD + NFPA 110.
750 kW Tier 2 diesel standby generator. mtu 12V1600G71S engine, 22.44L V-12 with turbocharging and aftercooling, LSA 49.3 M8 alternator.
Tier 23-phasecommercial-standbyindustrial
MTU
MTU 12V1600 DS900
900 kW diesel standby — max output from 12V1600 platform. Same footprint as DS600/DS750, 62 gph, 996 kWm gross. Compact sub-MW.
900 kW standby · Diesel · Liquid-cooled
Large commercial/data center standby at 900 kW. Diesel at 62 gph, compact 178 in footprint, 40°C radiator rating.
900 kW Tier 2 diesel standby generator. mtu 12V1600G91S engine, 22.44L V-12 with turbocharging and aftercooling, LSA 49.3 L9 alternator.
Data center continuous power at 1,600 kW DCCP. Diesel at 111 gph, flagship 12-cyl, HVO renewable fuel compatible.
1,750 kW standby / 1,600 kW DCCP diesel generator from MTU (Rolls-Royce). 57.2L V12 engine, EPA Tier 2 + SCAQMD, 380-13,800V. Maximum continuous output from the 12-cylinder Series 4000.
Tier 23-phasedata-centerhospital-large
MTU
MTU 16V2000 DS1000
1 MW standby from compact Series 2000 — 35.7L V16 at under 19,000 lb. Half the weight of Series 4000, 208-4,160V, water-to-air charge cooling.
1 MW standby · Diesel · Liquid-cooled
Compact 1 MW commercial/industrial standby. Diesel at 66.6 gph, lightweight for rooftop installs, N+1 paralleling arrays.
1,000 kW standby / 900 kW prime diesel generator from MTU (Rolls-Royce). 35.7L V16 engine, EPA Tier 2, 208-4,160V. Compact 1 MW class genset from the Series 2000 platform.
Data center / hospital 2 MW standby. Diesel at 143 gph, DCCP Uptime Tier III/IV, parts shared with DS2250/DS2500.
2,000 kW standby / 1,800 kW prime diesel generator from MTU (Rolls-Royce). 76.3L V16 engine, EPA Tier 2 + SCAQMD, 380-13,800V. Entry point to the 16-cylinder Series 4000 platform.
Tier 23-phasedata-centerhospital-large
MTU
MTU 16V4000 DS2250
2,250 kW standby / 2,045 kW DCCP — true 2 MW continuous from 76.3L V16. Same footprint as DS2000/DS2500, EPA Tier 2 + SCAQMD.
2.3 MW standby · Diesel · Liquid-cooled
Hyperscale data center at 2 MW continuous. Diesel at 163 gph, DCCP Uptime Tier III/IV, sweet spot for 1.8 MW IT loads.
2,250 kW standby / 2,045 kW prime diesel generator from MTU (Rolls-Royce). 76.3L V16 engine, EPA Tier 2 + SCAQMD, 380-13,800V. Mid-range 16-cylinder Series 4000 for data center and mission-critical applications.
Tier 23-phasedata-centerhospital-large
MTU
MTU 16V4000 DS2500
2,500 kW standby — max output from 16-cyl Series 4000. 76.3L V16 at ~3,350 bhp, EPA Tier 2 + SCAQMD, 380-13,800V, HVO compatible.
2.5 MW standby · Diesel · Liquid-cooled
Maximum single-frame standby at 2.5 MW. Diesel at 179 gph, standby-only rating, same footprint as DS2000/DS2250.
2,500 kW standby diesel generator from MTU (Rolls-Royce). 76.3L V16 engine, EPA Tier 2 + SCAQMD, 380-13,800V. Maximum output from the 16-cylinder Series 4000 platform.