Blue Star Power Systems · Mitsubishi Diesel Standby

Blue Star MD1000-01

1000 kW standby · Diesel · Liquid-cooled

1000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12H-Y2PTAW-1 37.1L V12 engine, S6L1D alternator, DCP7310 controller. Three-phase, 208–4160V.

Blue Star Power Systems Blue Star MD1000-01 generator — specifications and details
Standby power
1000 kW
Voltage options
120/208V, 240V, 277/480V, 347/600V, 4160V
Frequency / Phase
60 Hz · 3-phase
Engine
Mitsubishi S12H-Y2PTAW-1 · 37.1L
EPA / Emissions
Tier 2
Alternator
S6L1D-E

Overview#

The Blue Star MD1000-01 is a 1,000-kilowatt Tier 2 diesel standby generator powered by a Mitsubishi S12H-Y2PTAW-1 engine — a 37.1-liter, 12-cylinder V-configuration turbocharged and water/air-intercooled diesel producing 1,528 HP at 1800 RPM.

Blue Star Power Systems offers the MD1000-01 on a structural steel base with an S6L1D-E alternator and DCP7310 controller. It is three-phase only, available from 208V through 4160V.

The Mitsubishi S12H platform#

The S12H has a 5.91 in bore and a 6.89 in stroke, yielding 37.1 liters of displacement and 1,528 HP standby. The intercooler uses a separate water circuit (distinct from the jacket water circuit), requiring attention to two fluid systems at service intervals. Jacket water pump flow is 383 GPM, with an additional 132 GPM through the intercooler circuit.

When to spec the MD1000-01#

  • Sites requiring medium-voltage (4160V) output at 1 MW
  • Large industrial facilities, hospital campuses, and mission-critical data center backup systems

Our service experience#

At 22,675 lbs OPU, the MD1000-01 is a serious structural engineering concern — the equipment pad must be designed for this weight class and the radiator airflow of 42,191 CFM. At full load fuel consumption of 72.4 gph, a 500-gallon tank provides roughly 6.9 hours of runtime. Plan fuel delivery logistics for extended outage scenarios before commissioning.

Engineering specifications

Physical

Length
210 in
Width
96 in
Height
102 in
Dry weight
22,675 lb

Acoustic

Sound @ 7m, full load
89 dBA
Enclosure
Open

Fuel system & runtime

Fuel use @ full load
72.4 GPH
Fuel use @ 75% load
58.2 GPH
Fuel use @ 50% load
40 GPH

Thermal & ventilation

Heat to coolant
1,422,900 BTU/hr
Heat radiated
1,177,260 BTU/hr
Exhaust flow
9,534 CFM
Exhaust temp
910 °F
Combustion air
3,602 CFM
Ventilation air
42,191 CFM

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Blue Star MD1000-01

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Blue Star MD1000-01

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

3.6 hours(0.1 days)

Fuel consumption ≈ 55.85 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Before you buy this generator

Can a second qualified provider program a replacement controller for the Blue Star MD1000-01, using access issued to us?

Ask every supplier to answer in writing. Service access is part of what you are buying.

Open the 13-question checklist

Frequently Asked Questions

What engine does the MD1000-01 use?
The Mitsubishi S12H-Y2PTAW-1 — a 37.1-liter (2,265 cu in), 12-cylinder V-configuration turbocharged and water/air-intercooled diesel producing 1,528 HP at 1800 RPM for standby use. Compression ratio is 14.5:1. EPA Tier 2 certified.
What alternator does the MD1000-01 use?
The alternator selection is voltage-dependent. At 480V (4-lead wye) and 600V (4-lead wye), Blue Star specifies the S6L1D-E. At 208V (12-lead wye) and 240V (12-lead delta), the S6L1D-F is used. For the 4160V configuration, an MVWI734E medium-voltage alternator is installed. All are 4-pole, brushless single-bearing units.
What controller does the MD1000-01 use?
The DCP7310 Digital Control Panel — CAN Bus J1939, digital metering, RS-485, 8 programmable contact inputs, 10 contact outputs, cULus Listed, CE Approved, NFPA 110 Level 1 compatible. Remote monitoring is supported via the DSE2548 annunciator.
What is the altitude limit for the MD1000-01?
Rated power is available up to 3,280 ft (1,000 m) at ambient temperatures to 104°F (40°C).

Compatible equipment

More in the Mitsubishi Diesel Standby

800–2000 kW Tier 2 diesel standby power on open-architecture Mitsubishi V12 and V16 platforms.

Similar models

Blue Star Power Systems Blue Star MD800-01 800 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star MD800-01

800 kW standby · Diesel · Liquid-cooled

800 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12A2-Y2PTAW-2 33.9L V12 engine, S6L1D alternator, DCP7310 controller. Three-phase, 208–4160V.

Tier 23-phaseindustrialmunicipal
Blue Star Power Systems Blue Star MD1250-01 1.3 MW liquid-cooled standby generator

Blue Star Power Systems

Blue Star MD1250-01

1.3 MW standby · Diesel · Liquid-cooled

1250 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S12R-Y2PTAW-1 49.0L V12 engine, S6L1D alternator, DCP7310 controller. Three-phase, 208–4160V.

Tier 23-phaseindustrialmunicipal
Blue Star Power Systems Blue Star PD600-01 600 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star PD600-01

600 kW standby · Diesel · Liquid-cooled

600 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Perkins 2806C-E18TAG3 six-cylinder engine with charge air cooling, HCI534E alternator, DSE DCP7310 controller.

Tier 23-phasecommercialindustrial

Services for the Blue Star MD1000-01

Need service or parts for the Blue Star MD1000-01?

We service every major OEM and stock genuine parts for the most common models.

Last reviewed: