MTU

Series 4000 Diesel

1250–2500 kW · Diesel · 6 models

MTU Series 4000 diesel generators: 1250–2500 kW on MTU 12V4000 and 16V4000 V-engines, Tier 2, for data centers, large hospitals, and high-rise mission-critical facilities.

MTU Series 4000 Diesel — product line overview
Power range
1250–2500 kW
Fuel options
Diesel
Voltage options
380V, 416V, 440V, 480V, 600V, 4160V, 12470V, 13200V, 13800V
Models available
6
Engine platform
MTU
EPA / Emissions
Tier 2
Data Centerhospital-largemission-criticalhigh-risecampusindustrial-heavyparalleling-array

Series Overview#

The MTU Series 4000 Diesel from Rolls-Royce spans six models from 1,250 to 2,500 kilowatts of standby capacity: a 57.2-liter V12 for the three lower-output models and a 76.3-liter V16 for the three higher-output models.

The six models divide into two sublines: the 12V4000 platform (DS1250, DS1500, DS1750) rated 1,250–1,750 kW standby, and the 16V4000 platform (DS2000, DS2250, DS2500) rated 2,000–2,500 kW standby.

All six cited data sheets list three-phase output at 60 Hz, EPA Tier 2 certification and SCAQMD approval, with voltages from 380V through 13,800V. The medium-voltage options are 4,160V, 12,470V, 13,200V and 13,800V.

How to Choose#

The Series 4000 selection is organized around the engine platform boundary:

12V4000 subline (V12, 57.2L):

  • DS1250 (1,250 kW standby): the lowest rating in the Series 4000.
  • DS1500 (1,500 kW standby): standby rating with a 50 °C radiator ambient capacity.
  • DS1750 (1,750 kW standby): the highest rating of the three V12 sheets.

16V4000 subline (V16, 76.3L):

  • DS2000 (2,000 kW standby): the 16V4000G74S engine, 2,280 kWm.
  • DS2250 (2,250 kW standby): the 16V4000G84S engine, 2,500 kWm on the 40 °C sheet.
  • DS2500 (2,500 kW standby): the 16V4000G94S engine, 2,740 kWm, the highest rating of the six sheets.

For voltage configuration, medium-voltage options (4,160V and above) require coordination with the electrical engineer.

Common Applications#

  • Large hospitals: NFPA 110 compatible controls; the data sheets state that rated load is accepted in one step per NFPA 110.
  • High-rise and large campuses: Buildings and campuses with central plant electrical distribution where a single generator position must carry the full facility standby load.

Service & Maintenance#

The cited data sheets list a 24 VDC starting system with group 8D batteries and a system coolant capacity of 154 gallons (583 L) on the 12V4000 models.

Application Guidance#

The MTU Series 4000 covers single-unit standby at 1,250–2,500 kW. This series is not appropriate when the standby requirement is below 1,250 kW — the MTU Series 2000 DS1000 covers 1,000 kW standby and the MTU 12V1600 Series covers 750–900 kW. Where Tier 4 Final compliance is required, the Series 4000's Tier 2 certification will not meet that standard; confirm with the AHJ whether emergency standby use is exempt.

All Series 4000 Diesel Models

ModelStandby kW ▲Prime kWVoltageEngineEmissionsFuel
MTU 12V4000 DS12501250—380V, 416V, 440VMTU 12V4000G74STier 2diesel
MTU 12V4000 DS15001500—380V, 416V, 440VMTU 12V4000G74S—diesel
MTU 12V4000 DS17501750—380V, 416V, 440VMTU 12V4000G84STier 2diesel
MTU 16V4000 DS20002000—380V, 416V, 440VMTU 16V4000G74STier 2diesel
MTU 16V4000 DS22502250—380V, 416V, 440VMTU 16V4000G84STier 2diesel
MTU 16V4000 DS25002500—380V, 416V, 440VMTU 16V4000G94STier 2diesel

Frequently Asked Questions

What ratings do the Series 4000 data sheets print?
The cited data sheets for all six models are 60 Hz standby sheets: 1,250, 1,500 and 1,750 kWe on the 12V4000 and 2,000, 2,250 and 2,500 kWe on the 16V4000. Standby ratings apply to installations served by a reliable utility source, with no overload capability.
What voltage configurations are available in the Series 4000?
The cited Series 4000 data sheets print nine three-phase voltages: 380V, 416V, 440V, 480V, 600V, 4,160V, 12,470V, 13,200V and 13,800V.
How do the 12V4000 and 16V4000 platforms differ?
The 12V4000 is a 57.2-liter V12 rated 1,250–1,750 kW standby. The 16V4000 is a 76.3-liter V16 rated 2,000–2,500 kW standby. The data sheets print the same 17 cm (170 mm) bore and 21 cm (210 mm) stroke for both.
What starting system does the Series 4000 use?
The cited data sheets list a 24 VDC starting system with group 8D batteries.