Power range
159–400 kW
Fuel options
Natural Gas / LPG
Voltage options
120/208V, 120/240V, 277/480V, 347/600V
Models available
5
Engine platform
PSI
commercial-standbyindustrial-standby

Series Overview#

The Hipower HNG Series covers the 159 to 400 kW stationary natural gas standby segment with five models powered by PSI spark-ignited engines. All five are EPA certified. The series is three-phase only, supporting 120/208V, 277/480V, and 347/600V — the broadest voltage range in Hipower's stationary gas lineup and one that accommodates the full range of US commercial electrical services as well as Canadian 600V distribution.

At 159–400 kW, the HNG occupies a capacity band where diesel standby at equivalent output would require a large storage tank, SPCC compliance plan, and ongoing fuel management. Natural gas supply from the utility eliminates all of this. The HNG-400 is the upper limit of Hipower's stationary natural gas line; above 400 kW, the HRNG series continues with trailer-mounted configurations, and the HNI series provides PSI-powered stationary units from 30 to 1,000 kW.

The HNG is distinct from the HNI in its three-phase-only design and three-voltage support — the HNI covers more of the range but the HNG may be preferred for specific commercial projects where three-phase output and 347/600V support are required and the simpler product line is preferred. Both series use PSI engines.

How to Choose#

Coverage within the HNG range: The HNG-160 (159 kW), HNG-210 (208 kW), HNG-265 (263 kW), HNG-355 (354 kW), and HNG-400 (400 kW) provide five distinct output steps in this range. Select the model that provides 10–20% headroom above the calculated standby load — natural gas engines benefit from load margin to maintain clean combustion and consistent speed regulation.

Voltage selection: All five models support 120/208V, 277/480V, and 347/600V. For US commercial buildings, 277/480V is most common. For Canadian installations or US facilities with legacy 600V distribution (common in older industrial facilities), the 347/600V option is available from the factory — not a field modification.

Gas supply requirements: At 159–400 kW, the gas service infrastructure must be appropriately sized. A properly calibrated gas pressure regulator and supply line with adequate flow capacity are prerequisites. At 400 kW (HNG-400), gas supply deficiency at full load is the documented primary risk — verify regulator capacity and confirm the supply line can support the full BTU demand before installation.

Common Applications#

  • Commercial standby: All five HNG models are rated for commercial standby. Large office buildings, mid-size medical facilities, commercial mixed-use developments, and large retail anchors in the 159–400 kW class are the core commercial market. Natural gas eliminates the diesel tank, SPCC plan, and delivery schedule at a scale where diesel storage becomes a real operational burden.
  • Industrial standby: All five models carry industrial standby ratings, covering manufacturing operations, food processing, and distribution facilities with established natural gas service where diesel logistics are operationally unacceptable or cost-prohibitive at this scale.

Application Guidance#

The Hipower HNG Series is purpose-built for commercial and industrial facilities with established natural gas service needing three-phase stationary standby at 159 to 400 kW — the scale where diesel storage at equivalent output requires a 750-gallon-plus tank, an SPCC plan, and ongoing fuel management that commercial operators routinely seek to eliminate. The 347/600V option accommodates Canadian installations and US facilities with legacy 600V distribution from the same factory build.

The HNG is not appropriate above 400 kW stationary — the Hipower HNI Series continues gas standby coverage through 1,000 kW and includes PSI-powered models across a broader 17-model lineup that overlaps with the HNG range. For facilities where diesel is the only option (no gas service, or critical applications where gas supply reliability is a concern), the Hipower HFW Series (60–350 kW, Tier 3) and Hipower HDI Series (60–2,000 kW) cover diesel standby in this output band. For competing stationary natural gas in the 159–400 kW range, the Blue Star PSI Large Gaseous and CAT G Series Gas generators are the primary alternatives.

All HNG Series (Stationary Natural Gas) Models

ModelStandby kW ▲Prime kWVoltageEngineEmissionsFuel
Hipower HNG-160159—120/208V, 120/240V, 277/480VPSI 8.1 LT—natural gas, lpg
Hipower HNG-210208—120/208V, 120/240V, 277/480VPSI 11.1L—natural gas, lpg
Hipower HNG-265263—120/208V, 120/240V, 277/480VPSI 14.6L—natural gas, lpg
Hipower HNG-355354—120/208V, 120/240V, 277/480VPSI 18.3L—natural gas, lpg
Hipower HNG-400400—120/208V, 120/240V, 277/480VPSI 21.9L—natural gas, lpg

Frequently Asked Questions

What engine powers HNG generators?
All five HNG models use PSI (Power Solutions International) spark-ignited engines configured for natural gas or LPG operation. Specific PSI engine configurations scale across the 159–400 kW range.
How does the HNG series relate to the HGM and HNI series?
The HGM covers 53–150 kW in a compact commercial format. The HNG covers 159–400 kW in a stationary three-phase format. The HNI spans 30–1,000 kW with both single- and three-phase output. The HNG sits between the HGM and the larger HNI models, specifically addressing the 160–400 kW stationary three-phase commercial and industrial standby segment.
Does the HNG series support 347/600V?
Yes. All five HNG models support 347/600V alongside 120/208V and 277/480V, making them suitable for Canadian installations and US facilities with 600V distribution.

Related Product Lines

Application Engineering

Need help selecting a HNG Series (Stationary Natural Gas) model?

Our engineers spec across 19 brands and 900+ models — diesel, gaseous, portable, and prime power — with no single-brand obligation.

Services for the HNG Series (Stationary Natural Gas)

Need Help Choosing?

Our team can help you find the right Hipower Systems generator for your application.