Power range
800–2000 kW
Fuel options
Diesel
Voltage options
120/208V, 120/240V, 277/480V, 346/600V, 127/220V
Models available
4
Engine platform
Mitsubishi
EPA / Emissions
Tier 2
Data CenterhospitalIndustrialcampusmunicipalutilitylarge-commercial

Series Overview#

The Gillette SPMI Series is the company's large-format diesel standby lineup, covering 800 kW to 2,000 kW (2 MW) across four models. Every unit in the series is built on a Mitsubishi liquid-cooled V-engine.

The series uses two engine families. The SPMI-8000 (800 kW) and SPMI-1M (1,000 kW) run Mitsubishi's S12-series V12 diesels — the S12A2 at 33.9L and the S12H at 37.1L respectively. The SPMI-1.5M (1,500 kW) and SPMI-2M (2,000 kW) both use the S16R V16 at 65.37L displacement: the 1.5M uses the S16R-Y2PTAW-1 rated 2,346 bhp standby and the 2M uses the S16R-Y2PTAW2-1 rated 2,923 bhp. All four models pair with Stamford AVK alternators and the Deep Sea 7420 MKII controller having UL-6200 certification.

Gillette's value proposition at this scale is the same as in the rest of their lineup: factory-direct pricing against a Mitsubishi engine platform that any qualified industrial diesel technician can service, using a DSE controller that any controls technician can program. Typical lead times are 3–7 days.

All SPMI models are three-phase and liquid-cooled; the sheets state that all emergency stationary diesel engines are Tier II compliant. Buyers with a different emissions requirement should contact OnPoint.

How to Choose#

800 kW — SPMI-8000 (Mitsubishi S12A2): The 800 kW model. The 33.9L S12A2 V12 produces the rated 800 kW standby. The sheet lists five three-phase, 60 Hz voltages: 120/208V, 120/240V, 277/480V, 127/220V and 346/600V.

1,000 kW / 1 MW — SPMI-1M (Mitsubishi S12H): The 37.1L S12H V12 delivers 1,000 kW standby; the sheet lists the same five three-phase, 60 Hz voltages as the SPMI-8000. If load sizing lands between 800 kW and 1,500 kW, compare the SPMI-1M against the SPMI-1.5M with your AHJ on the 500 kW headroom difference.

1,500 kW — SPMI-1.5M (Mitsubishi S16R): The S16R V16 model; the sheet lists 277/480V and 346/600V. If your distribution system runs 208V, the SPMI-8000 or SPMI-1M are the SPMI models whose sheets list 120/208V.

2,000 kW / 2 MW — SPMI-2M (Mitsubishi S16R): The S16R-Y2PTAW2-1 V16 model rated 2,000 kW standby. Its open set is listed at 240 x 102 x 135 in, the same as the SPMI-1.5M's open set, so it provides 500 kW more rated output at the listed open-set dimensions. The sheet lists 277/480V and 346/600V.

Voltage selection: For loads requiring 120/208V or 120/240V service, your options within the SPMI series are limited to the SPMI-8000 and SPMI-1M. The 1.5M and 2M sheets list 277/480V and 346/600V.

Common Applications#

  • Data centers: The SPMI series covers 800 kW to 2 MW single-generator standby for data center loads.

  • Hospitals and healthcare campuses: All four SPMI models appear in hospital and campus application contexts. These generators serve hospital and campus emergency power loads sized to their kW ratings. The Stamford AVK alternators are brushless and PMG excited, with voltage regulation of 1/2% from no load to full load.

  • Industrial plants and manufacturing facilities: Heavy manufacturing, process operations, and industrial facilities with significant motor loads should check each model's sheet, which lists three-phase motor starting kVA at 30% voltage dip by voltage; match it to your largest motor.

  • Municipal infrastructure and utilities: Water treatment plants, pumping stations, and public utility infrastructure requiring reliable large-scale standby power.

  • Campus-wide emergency systems: University campuses, hospital complexes, and multi-building commercial developments using a centralized standby approach rather than distributed unit-by-unit backup. The SPMI series is sized for the central plant model.

Service & Maintenance#

Each SPMI sheet lists the fuel injection pump as x2, so clean fuel matters across the whole series.

Practical maintenance priorities for SPMI operators: (1) Fuel quality management is essential. At 800–2000 kW, the fuel consumption rates are substantial; stored diesel in large tanks is prone to microbial contamination and water accumulation. (2) Battery bank condition monitoring — each sheet lists a 24 VDC starting system with four 12 VDC batteries and a battery charger.

Application Guidance#

The Gillette SPMI Series is purpose-built for large-scale single-engine diesel standby from 800 kW to 2 MW where factory-direct pricing against Mitsubishi S-series V-engines is the value proposition and 3–7 day lead time matters. The SPMI-8000 and SPMI-1M sheets list 120/208V and 120/240V configurations. For facilities where the distribution system runs 208V and a 1 MW standby requirement exists, the SPMI-1M is the 1 MW SPMI model whose sheet lists 120/208V. The 7420 MKII controller software is freely downloadable, per the spec sheets.

This is a Tier II series; for other emissions requirements, contact OnPoint. For requirements below 800 kW on industrial diesel, see the Gillette SPVD Series and the Gillette SPJD Series. For requirements above 2 MW, consult OnPoint for options.

FAQ#

See frontmatter for FAQ items.

All SPMI Series (Industrial Diesel - Mitsubishi) Models

ModelStandby kW ▲Prime kWVoltageEngineEmissionsFuel
Gillette SPMI-8000800—120/208V, 120/240V, 277/480VMitsubishi S12A2-Y2PTAW-2Tier 2diesel
Gillette SPMI-1M1000—120/208V, 120/240V, 277/480VMitsubishi S12H-Y2PTAW-1Tier 2diesel
Gillette SPMI-1.5M1500—277/480V, 346/600VMitsubishi S16R-Y2PTAW-1Tier 2diesel
Gillette SPMI-2M2000—277/480V, 346/600VMitsubishi S16R-Y2PTAW2-1Tier 2diesel

Frequently Asked Questions

What is the kW range of the Gillette SPMI series?
The SPMI series spans 800 kW (SPMI-8000) to 2,000 kW / 2 MW (SPMI-2M).
What engines power the SPMI series?
All SPMI models use Mitsubishi diesel V-engines: the S12A2 (33.9L V12) in the SPMI-8000, the S12H (37.1L V12) in the SPMI-1M, and the S16R (65.37L V16) in both the SPMI-1.5M and SPMI-2M.
What emissions tier do SPMI generators meet?
The spec sheets for all four SPMI models state that all engines are EPA emissions certified and that all emergency stationary diesel engines are Tier II compliant.
What voltages are available across the SPMI series?
The SPMI-8000 and SPMI-1M sheets list 120/208V, 120/240V, 277/480V, 127/220V, and 346/600V (three-phase, 60 Hz). The SPMI-1.5M and SPMI-2M sheets list 277/480V and 346/600V.
What controller is used on the SPMI series?
All four SPMI sheets list the Deep Sea 7420 MKII controller, having UL-508 and UL-6200 certification: an auto start mains (utility) failure module for single gen-set applications, with remote start (on load) and monitoring by direct USB cable, LAN, or the built-in web interface.

Related Product Lines

Why we recommend Gillette

When budget and lead time matter for industrial diesel standby, we recommend Gillette. Same John Deere and Volvo engines as the major brands, at lower cost, with lead times that the big OEMs can't touch.

We pitch Gillette for industrial diesel applications where buyers prioritize value and open-architecture serviceability. The John Deere and Volvo engines are the same platforms we service daily across other brands, so our technicians maintain Gillette units with full confidence.

See all Gillette generators →

Application Engineering

Need help selecting a SPMI Series (Industrial Diesel - Mitsubishi) model?

Our engineers spec across 19 brands and 900+ models — diesel, gaseous, portable, and prime power — with no single-brand obligation.

Services for the SPMI Series (Industrial Diesel - Mitsubishi)

Need Help Choosing?

Our team can help you find the right Gillette generator for your application.