Kohler · REOZ Series (Diesel Industrial Large)

New

Kohler 1250ROZMC

1120 kW standby / 1016 kW prime · Diesel · Liquid-cooled

1120 kW diesel 1500 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

Kohler 1250ROZMC — product photo
Standby power
1120 kW / 1016 kW prime
Voltage options
277/480V, 4160V, 12470V, 13200V, 13800V
Frequency / Phase
50 Hz · 3-phase
Engine
Mitsubishi See spec sheet · 49L
Alternator
Kohler 7M4046
data-centerhealthcareindustrial-heavygovernmentmission-criticalcommercial

Overview#

The Kohler 1250ROZMC is a 1120-kilowatt standby (1016 kW prime) diesel generator designed for 1500 RPM / 50 Hz operation. This non-certified unit is intended for export and non-regulated markets where US EPA certification is not required.

Our service experience#

OnPoint Generators services Kohler REOZ diesel generators throughout Northern California. Units in this class require specialized service capabilities including medium-voltage expertise and large-capacity load bank testing.

Engineering specifications

Physical

Length
241.1 in
Width
87.9 in
Height
101.2 in
Wet weight
26,500 lb

Fuel system & runtime

Fuel use @ full load
93.6 GPH
Fuel use @ 75% load
69.4 GPH

Photos

Kohler 1250ROZMC — product photo

Documents & downloads

Spec sheets & manuals

Request a quote

Get pricing & lead time on the Kohler 1250ROZMC

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Kohler 1250ROZMC

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

2.8 hours(0.1 days)

Fuel consumption ≈ 72.21 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Kohler 1250ROZMC under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel injection pump / injectorsHard starting, black smoke, uneven cylinder loading10,000+moderate
TurbochargerPower loss, excessive exhaust smoke, oil carryover12,000+moderate
Cooling system (hoses / thermostat)Overtemperature fault, coolant loss10,000+minor
Battery (starting)Slow crank, failed exercise8,760+minor

Frequently Asked Questions

What engine powers the Kohler 1250ROZMC?
The 1250ROZMC uses a Mitsubishi diesel engine running at 1500 RPM. Refer to the Kohler spec sheet for complete engine details.
Why does the 1250ROZMC run at 1500 RPM?
The ROZMC series runs at 1500 RPM for 50 Hz export applications. These units are non-certified for EPA and are intended for markets without US emissions requirements.
Does OnPoint service the Kohler 1250ROZMC?
Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 1120 kW class.

Similar models

Kohler KD1000 backup generator

Kohler

New

Kohler KD1000

1 MW standby · Diesel · Liquid-cooled

1000 kW diesel industrial standby generator. Megawatt-class KD Series unit for data centers, hospitals, and mission-critical infrastructure.

Tier 23-phasedata-centerhealthcare
Kohler KD1250-4 backup generator

Kohler

New

Kohler KD1250-4

1.3 MW standby · Diesel · Liquid-cooled

1250 kW EPA Tier 4 Final diesel industrial standby generator. Dual-certified (emergency and non-emergency) for mission-critical and prime power applications.

Tier 4 Final3-phasedata-centerhealthcare
Kohler KD1250-A backup generator

Kohler

New

Kohler KD1250-A

1.3 MW standby · Diesel · Liquid-cooled

1250 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and large commercial facilities.

Tier 23-phasedata-centerhealthcare
Kohler 1250REOZMD backup generator

Kohler

New

Kohler 1250REOZMD

1.3 MW standby · Diesel · Liquid-cooled

1280 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

Tier 23-phasedata-centerhealthcare
Kohler KD1350 backup generator

Kohler

New

Kohler KD1350

1.4 MW standby · Diesel · Liquid-cooled

1350 kW diesel industrial standby generator. Mid-range KD Series platform for data centers, healthcare, and large commercial applications.

Tier 23-phasedata-centerhealthcare
Kohler KD1500 backup generator

Kohler

New

Kohler KD1500

1.5 MW standby · Diesel · Liquid-cooled

1500 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure.

Tier 23-phasedata-centerhealthcare

Need service or parts for the Kohler 1250ROZMC?

We service every major OEM and stock genuine parts for the most common models.