Kohler · KD Series (Industrial Diesel)

Kohler KD1000

1000 kW standby / 900 kW prime · Diesel · Liquid-cooled

1000 kW diesel industrial standby generator. Megawatt-class KD Series unit for data centers, hospitals, and mission-critical infrastructure.

Kohler Kohler KD1000 generator — specifications and details
Standby power
1000 kW / 900 kW prime
Voltage options
277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Kohler KD27V12 · 27L
EPA / Emissions
Tier 2
Alternator
KH04830TO4D

Overview#

The Kohler KD1000 is a 1000-kilowatt diesel industrial standby generator from Kohler's KD Series platform. As a true megawatt-class unit, it serves data centers, hospitals, and large commercial campuses requiring substantial backup power capacity.

KD Series platform#

The 60 Hz generator set offers a UL 2200 listing and meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. Hurricane Rated Enclosure is listed among the available options.

Our service experience#

OnPoint Generators provides installation, maintenance, and emergency service for Kohler KD Series generators throughout Northern California. Our technicians are experienced with large diesel platforms in the megawatt class, including load bank testing, fuel system maintenance, and cooling system service for high-capacity industrial units.

Engineering specifications

Physical

Wet weight
17,821 lb

Acoustic

Sound @ 7m, full load
96 dBA
Enclosure
Open

Fuel system & runtime

Fuel use @ full load
70.9 GPH
Fuel use @ 75% load
55.3 GPH
Fuel use @ 50% load
38.6 GPH

Photos

Kohler KD1000 — product photo

Documents & downloads

Ready to order this model?

Configure your Kohler KD1000

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Kohler KD1000

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

3.7 hours(0.2 days)

Fuel consumption ≈ 54.69 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Before you buy this generator

Can a second qualified provider program a replacement controller for the Kohler KD1000, using access issued to us?

Ask every supplier to answer in writing. Service access is part of what you are buying.

Open the 13-question checklist

Frequently Asked Questions

What is the standby rating of the Kohler KD1000?
Per the Kohler spec sheet, the KD1000 is rated at 1000 kW / 1250 kVA standby and 900 kW / 1125 kVA prime continuous at 0.8 power factor, 60 Hz, 1800 RPM.
Is the Kohler KD1000 EPA Tier 4 certified?
No. The KD1000 is EPA certified for stationary emergency use.
What alternator type does the KD1000 use?
The KD1000 uses a brushless, permanent-magnet pilot exciter alternator.

Compatible equipment

More in the KD Series (Industrial Diesel)

Kohler-engineered megawatt-class diesel gensets from 900 to 4000 kW for mission-critical facilities.

Why we recommend Kohler

Kohler is our primary recommendation for commercial standby power. We sell and service the full Kohler line — RCA residential, RCL light commercial, KG industrial diesel, and REOZ large-frame — and our technicians are factory-trained on every product family.

We are an authorized Kohler dealer with factory-trained technicians. Kohler is the majority of our new generator sales today, spanning residential through large industrial. Our parts inventory is stocked for same-day Kohler service.

See all Kohler generators →

Similar models

Kohler Kohler KD900 900 kW liquid-cooled standby generator

Kohler

Kohler KD900

900 kW KD Series -- Kohler KD27V12 with PM pilot exciter.

900 kW standby · Diesel · Liquid-cooled

900 kW diesel industrial standby generator.

Tier 23-phasedata-centerhealthcare
Kohler Kohler KD1250-4 1.3 MW liquid-cooled standby generator

Kohler

Kohler KD1250-4

Megawatt-class KD at 1250 kW -- Kohler KD36V16, APM603 controller.

1.3 MW standby · Diesel · Liquid-cooled

1250 kW EPA Tier 4 diesel industrial standby generator.

3-phasedata-centerhealthcare
Kohler Kohler 1250ROZMC 1.3 MW liquid-cooled standby generator

Kohler

Kohler 1250ROZMC

1280 kW diesel standby -- Mitsubishi S12R V12 turbo, sub-3% THD. Decision-Maker controller for load management and paralleling.

1.3 MW standby · Diesel · Liquid-cooled

1280 kW diesel 1800 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

3-phasedata-centerhealthcare

Services for the Kohler KD1000

Need service or parts for the Kohler KD1000?

We service every major OEM and stock genuine parts for the most common models.