Kohler · REOZ Series (Diesel Industrial Large)

New

Kohler 1250REOZMD

1280 kW standby / 1160 kW prime · Diesel · Liquid-cooled

1280 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

Kohler 1250REOZMD — product photo
Standby power
1280 kW / 1160 kW prime
Voltage options
277/480V, 4160V, 12470V, 13200V, 13800V
Frequency / Phase
60 Hz · 3-phase
Engine
Mitsubishi S12R-Y2PTAW-1 · 49L
EPA / Emissions
Tier 2
Alternator
Kohler 7M4046
data-centerhealthcareindustrial-heavygovernmentmission-criticalcommercial

Overview#

The Kohler 1250REOZMD is a 1280-kilowatt standby (1160 kW prime) diesel generator powered by a Mitsubishi engine at 1800 RPM. This industrial-class unit serves mission-critical standby applications including data centers, hospitals, and large commercial facilities.

Our service experience#

OnPoint Generators services Kohler REOZ diesel generators throughout Northern California. Units in this class require specialized service capabilities including medium-voltage expertise and large-capacity load bank testing.

Engineering specifications

Physical

Length
240.8 in
Width
87.9 in
Height
98.1 in
Wet weight
26,500 lb

Fuel system & runtime

Fuel use @ full load
103.4 GPH
Fuel use @ 75% load
75.1 GPH

Photos

Kohler 1250REOZMD — product photo

Documents & downloads

Spec sheets & manuals

Request a quote

Get pricing & lead time on the Kohler 1250REOZMD

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Kohler 1250REOZMD

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

2.5 hours(0.1 days)

Fuel consumption ≈ 79.77 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Kohler 1250REOZMD under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel injection pump / injectorsHard starting, black smoke, uneven cylinder loading10,000+moderate
TurbochargerPower loss, excessive exhaust smoke, oil carryover12,000+moderate
Cooling system (hoses / thermostat)Overtemperature fault, coolant loss10,000+minor
Battery (starting)Slow crank, failed exercise8,760+minor

Frequently Asked Questions

What engine powers the Kohler 1250REOZMD?
The 1250REOZMD uses a Mitsubishi diesel engine running at 1800 RPM (model S12R-Y2PTAW-1).
What is the standby power rating of the 1250REOZMD?
The 1250REOZMD is rated at 1280 kW standby and 1160 kW prime per Kohler published specifications.
Does OnPoint service the Kohler 1250REOZMD?
Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 1280 kW class.

Similar models

Kohler KD1250-4 backup generator

Kohler

New

Kohler KD1250-4

1.3 MW standby · Diesel · Liquid-cooled

1250 kW EPA Tier 4 Final diesel industrial standby generator. Dual-certified (emergency and non-emergency) for mission-critical and prime power applications.

Tier 4 Final3-phasedata-centerhealthcare
Kohler KD1250-A backup generator

Kohler

New

Kohler KD1250-A

1.3 MW standby · Diesel · Liquid-cooled

1250 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and large commercial facilities.

Tier 23-phasedata-centerhealthcare
Kohler KD1350 backup generator

Kohler

New

Kohler KD1350

1.4 MW standby · Diesel · Liquid-cooled

1350 kW diesel industrial standby generator. Mid-range KD Series platform for data centers, healthcare, and large commercial applications.

Tier 23-phasedata-centerhealthcare
Kohler 1250ROZMC backup generator

Kohler

New

Kohler 1250ROZMC

1.1 MW standby · Diesel · Liquid-cooled

1120 kW diesel 1500 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

3-phasedata-centerhealthcare
Kohler KD1500 backup generator

Kohler

New

Kohler KD1500

1.5 MW standby · Diesel · Liquid-cooled

1500 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure.

Tier 23-phasedata-centerhealthcare
Kohler 1600ROZMC backup generator

Kohler

New

Kohler 1600ROZMC

1.6 MW standby · Diesel · Liquid-cooled

1560 kW diesel 1500 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

3-phasedata-centerhealthcare