Kohler · REOZ Series (Diesel Industrial Large)

New

Kohler 750REOZMD

760 kW standby / 690 kW prime · Diesel · Liquid-cooled

760 kW diesel commercial/industrial standby generator powered by Mitsubishi. Suitable for hospitals, data centers, and large commercial complexes.

Kohler 750REOZMD — product photo
Standby power
760 kW / 690 kW prime
Voltage options
277/480V, 4160V, 12470V, 13200V, 13800V
Frequency / Phase
60 Hz · 3-phase
Engine
Mitsubishi S12A2-Y2PTAW-2 · 33.93L
EPA / Emissions
Tier 2
Alternator
Kohler 5M4032
commercialhealthcaredata-centerindustrial-heavygovernmentmission-critical

Overview#

The Kohler 750REOZMD is a 760-kilowatt standby (690 kW prime) diesel generator powered by a Mitsubishi engine at 1800 RPM. This unit serves large commercial and industrial standby applications including hospitals, data centers, and manufacturing facilities.

Our service experience#

OnPoint Generators services Kohler REOZ diesel generators throughout Northern California. We service units in this class with annual NFPA 110 maintenance, semi-annual inspections, and load bank testing up to full rated capacity.

Engineering specifications

Physical

Length
195.6 in
Width
73 in
Height
95.3 in
Wet weight
17,400 lb

Fuel system & runtime

Fuel use @ full load
61.4 GPH
Fuel use @ 75% load
43.3 GPH

Photos

Kohler 750REOZMD — product photo

Documents & downloads

Spec sheets & manuals

Request a quote

Get pricing & lead time on the Kohler 750REOZMD

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Kohler 750REOZMD

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

4.2 hours(0.2 days)

Fuel consumption ≈ 47.37 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Kohler 750REOZMD under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel injection pump / injectorsHard starting, black smoke, uneven cylinder loading10,000+moderate
TurbochargerPower loss, excessive exhaust smoke, oil carryover12,000+moderate
Cooling system (hoses / thermostat)Overtemperature fault, coolant loss10,000+minor
Battery (starting)Slow crank, failed exercise8,760+minor

Frequently Asked Questions

What engine powers the Kohler 750REOZMD?
The 750REOZMD uses a Mitsubishi diesel engine running at 1800 RPM (model S12A2-Y2PTAW-2).
What is the standby power rating of the 750REOZMD?
The 750REOZMD is rated at 760 kW standby and 690 kW prime per Kohler published specifications.
Does OnPoint service the Kohler 750REOZMD?
Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 760 kW class.

Similar models

Kohler KD900 backup generator

Kohler

New

Kohler KD900

900 kW standby · Diesel · Liquid-cooled

900 kW diesel industrial standby generator. Entry-level KD Series platform for data centers, healthcare, and mission-critical facilities.

Tier 23-phasedata-centerhealthcare
Kohler 600REOZVB backup generator

Kohler

New

Kohler 600REOZVB

600 kW standby · Diesel · Liquid-cooled

600 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.

Tier 23-phasecommercialhealthcare
Kohler 550REOZVB backup generator

Kohler

New

Kohler 550REOZVB

550 kW standby · Diesel · Liquid-cooled

550 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.

Tier 23-phasecommercialhealthcare
Kohler 500REOZVC backup generator

Kohler

New

Kohler 500REOZVC

515 kW standby · Diesel · Liquid-cooled

515 kW diesel commercial/industrial standby generator powered by Volvo. Suitable for hospitals, data centers, and large commercial complexes.

Tier 23-phasecommercialhealthcare
Kohler 500REOZJB backup generator

Kohler

New

Kohler 500REOZJB

510 kW standby · Diesel · Liquid-cooled

510 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.

Tier 23-phasecommercialhealthcare
Kohler 500REOZJ backup generator

Kohler

New

Kohler 500REOZJ

500 kW standby · Diesel · Liquid-cooled

500 kW diesel commercial/industrial standby generator powered by John Deere. Suitable for hospitals, data centers, and large commercial complexes.

Tier 23-phasecommercialhealthcare

Need service or parts for the Kohler 750REOZMD?

We service every major OEM and stock genuine parts for the most common models.