Overview#
The Kohler 2000REOZMD is a 2,000-kilowatt standby (1,820 kW prime) diesel generator powered by a Mitsubishi S16R-Y2PTAW2-1 — a 65.4 L, 16-cylinder V-configuration turbocharged diesel at 1800 RPM.
The 2000REOZMD is EPA Tier 2 certified for stationary emergency applications, UL 2200 listed, and meets NFPA 110 Level 1 requirements. It supports both 480V low-voltage and medium-voltage outputs (4,160V; 12.47 kV; 13.2 kV; 13.8 kV).
Specifications#
| Spec | Value |
|---|---|
| Standby Power | 2,000 kW |
| Prime Power | 1,820 kW |
| Voltage options | 277/480V, 4,160V, 12.47 kV, 13.2 kV, 13.8 kV |
| Frequency | 60 Hz |
| Engine | Mitsubishi S16R-Y2PTAW2-1 |
| Engine type | 4-cycle turbocharged |
| Cylinders | 16 V-configuration |
| Displacement | 65.4 L (3,989 cu. in.) |
| Compression ratio | 14.0:1 |
| Rated RPM | 1,800 |
| Alternator | Kohler 7M4054 |
| Fuel | Diesel (#2 / HVO / RD) |
| Cooling | Liquid (radiator) |
| Emissions tier | EPA Tier 2 stationary emergency |
| Fuel consumption (100% standby load) | 160.1 gph |
| Fuel consumption (75% standby load) | 116.8 gph |
Service & Maintenance#
Oil pan capacity is 200 L (211 qt), 230 L (243 qt) with filter. Jacket water capacity is 170 L (44.9 gal); total radiator system capacity is 367 L (96.9 gal). The high-ambient radiator configuration supports operation up to 50°C (122°F). Four 1,150 CCA batteries power dual 24V starter motors.
Common Failure Modes#
At 2,000 kW, the fuel system delivers up to 660 L/hr (174 gph) maximum flow.
The exhaust flow at rated load is 544 m³/min (19,209 cfm) at 526°C (979°F). Turbocharger oil supply and return lines should be inspected at every major service.
Cooling system components require attention given the large system volumes (367 L radiator). The charge cooler circuit (920 L/min flow) must be maintained separately from the jacket water circuit.
Starting battery condition — four 1,150 CCA batteries power dual 24V starters.
Our service experience#
OnPoint Generators provides installation, maintenance, load bank testing, and emergency service for Kohler industrial generators throughout Northern California and the Central Valley. The 2000REOZMD is the largest single-unit generator we regularly service. At 2 MW, full-load testing requires 2 MW+ load banks and careful coordination with facility electrical teams. We provide factory-level Mitsubishi S16R service capabilities including fuel system calibration, turbocharger service, and major overhaul planning for accounts that need lifecycle management on these assets.
FAQ#
Q: What engine powers the Kohler 2000REOZMD? A: The 2000REOZMD uses a Mitsubishi S16R-Y2PTAW2-1 — a 65.4 L, 16-cylinder V-configuration turbocharged diesel at 1800 RPM, EPA Tier 2 certified for stationary emergency standby.
Q: What is the standby power rating of the 2000REOZMD? A: 2,000 kW standby and 1,820 kW prime at 0.8 power factor per Kohler spec sheet G5-369.
Q: Does OnPoint service the Kohler 2000REOZMD? A: Yes. OnPoint Generators provides maintenance, repair, and full-load bank testing for Kohler 2000REOZMD generators throughout Northern California.