Overview#
The Kohler 1750REOZMD is a 1,780-kilowatt standby (1,650 kW prime) diesel generator powered by a Mitsubishi S16R-Y2PTAW2-1 — a 65.4 L, 16-cylinder V-configuration turbocharged diesel at 1800 RPM. The 1750REOZMD is Tier 2 EPA-Certified for Stationary Emergency Applications.
This unit is rated at 277/480V and 4160V. Additional alternator voltages are available including 12.47 kV, 13.2 kV, and 13.8 kV medium voltages. The 60 Hz generator set offers a UL 2200 listing.
The 1750REOZMD's Mitsubishi S16R-Y2PTAW2-1 engine produces up to 2,180 kWm (2,923 BHP) maximum power. A high ambient radiator system is listed at 50°C (122°F) ambient temperature.
Specifications#
| Spec | Value |
|---|---|
| Standby Power | 1,780 kW |
| Prime Power | 1,650 kW |
| Voltage options | 277/480V, 4160V, 12.47 kV, 13.2 kV, 13.8 kV |
| Frequency | 60 Hz |
| Engine | Mitsubishi S16R-Y2PTAW2-1 |
| Engine type | 4-cycle turbocharged |
| Cylinders | 16 V-configuration |
| Displacement | 65.4 L (3,989 cu. in.) |
| Compression ratio | 14.0:1 |
| Rated RPM | 1,800 |
| Alternator | Kohler 7M4052 |
| Fuel | Diesel (#2 / HVO / RD) |
| Cooling | Liquid (radiator) |
| Emissions tier | EPA Tier 2 stationary emergency |
| Fuel consumption (100% standby load) | 141.6 gph |
| Fuel consumption (75% standby load) | 106.6 gph |
Service & Maintenance#
The Mitsubishi S16R-Y2PTAW2-1 uses four cartridge oil filters. Oil pan capacity is 200 L (211 qt), 230 L (243 qt) with filter. Jacket water capacity is 170 L (44.9 gal); total radiator system capacity is 367 L (96.9 gal). Four 1,150 CCA batteries power dual 24V starter motors (dual 24V configuration).
Common Failure Modes#
Heat rejected to ambient air by the engine is 162 kW (9216 Btu/min.).
Our service experience#
OnPoint Generators provides installation, maintenance, load bank testing, and emergency service for Kohler industrial generators throughout Northern California and the Central Valley. The 1750REOZMD is one of the largest generators we service in the Bay Area's hospital and data center corridor. Accounts in this power class require 1 MW+ load banks for full-rated testing and certified medium-voltage technicians for switchgear work. We maintain OEM relationships with both Kohler/Rehlko and Mitsubishi's industrial engine division to support these installations.
FAQ#
Q: What engine powers the Kohler 1750REOZMD? A: The 1750REOZMD uses a Mitsubishi S16R-Y2PTAW2-1 — a 65.4 L, 16-cylinder V-configuration turbocharged diesel at 1800 RPM, EPA Tier 2 certified for stationary emergency.
Q: What is the standby power rating of the 1750REOZMD? A: 1,780 kW standby and 1,650 kW prime at 0.8 power factor per Kohler spec sheet G5-368.
Q: What medium-voltage options are available? A: The 1750REOZMD offers 4160 V on the 7M4370 and 7M4374 alternators. Additional alternator voltages are available including 12.47 kV, 13.2 kV, and 13.8 kV medium voltages.
Q: Does OnPoint service the Kohler 1750REOZMD? A: Yes. OnPoint Generators provides maintenance, repair, and full-load bank testing for Kohler REOZMD diesel generators throughout Northern California, including the 1,780 kW class.