Kohler · REOZ Series (Diesel Industrial Large)

Kohler 1750REOZMD

1780 kW standby / 1650 kW prime · Diesel · Liquid-cooled

1780 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

Kohler Kohler 1750REOZMD generator — specifications and details
Standby power
1780 kW / 1650 kW prime
Voltage options
277/480V, 4160V, 12470V, 13200V, 13800V
Frequency / Phase
60 Hz · 3-phase
Engine
Mitsubishi S16R-Y2PTAW2-1 · 65.4L
EPA / Emissions
Tier 2
Alternator
Kohler 7M4052

Overview#

The Kohler 1750REOZMD is a 1,780-kilowatt standby (1,650 kW prime) diesel generator powered by a Mitsubishi S16R-Y2PTAW2-1 — a 65.4 L, 16-cylinder V-configuration turbocharged diesel at 1800 RPM. As an EPA Tier 2 certified unit for stationary emergency applications, the 1750REOZMD is the US-domestic counterpart to the non-certified ROZMC variants, designed for mission-critical standby at data centers, hospitals, and large commercial facilities.

The REOZMD designation indicates the 1800 RPM (60 Hz) EPA-certified configuration. This unit supports both low-voltage (277/480V) and medium-voltage alternator options (4,160V; 12,470V; 13,200V; 13,800V), enabling direct integration into medium-voltage distribution systems without step-up transformers. The UL 2200 listing and NFPA 110 Level 1 capability make it suitable for the most demanding regulatory environments.

The 1750REOZMD's Mitsubishi S16R-Y2PTAW2-1 engine produces up to 2,180 kWm (2,923 BHP) maximum power, providing substantial derating headroom above the 1,780 kW standby rating. Available in high-ambient radiator configurations (rated to 50°C / 122°F), the unit operates in demanding climates without power derating.

Specifications#

SpecValue
Standby Power1,780 kW
Prime Power1,650 kW
Voltage options277/480V, 4,160V, 12,470V, 13,200V, 13,800V
Frequency60 Hz
EngineMitsubishi S16R-Y2PTAW2-1
Engine type4-cycle turbocharged
Cylinders16 V-configuration
Displacement65.4 L (3,989 cu. in.)
Compression ratio14.0:1
Rated RPM1,800
AlternatorKohler 7M4052
FuelDiesel (#2 / HVO / RD)
CoolingLiquid (radiator)
Emissions tierEPA Tier 2 stationary emergency
Fuel consumption (100% standby load)141.6 gph
Fuel consumption (75% standby load)106.6 gph

Service & Maintenance#

ServiceInterval
Oil changeEvery 500 hours or 12 months
Fuel filter replacementEvery 500 hours
Air filter replacementEvery 1,000 hours
Coolant flushEvery 6,000 hours or 5 years
Load bank testAnnually (NFPA 110 requirement)
Major overhaulEvery 20,000 hours

The Mitsubishi S16R-Y2PTAW2-1 uses four secondary cartridge oil filters. Oil pan capacity is 200 L (211 qt) dry, 230 L (243 qt) with filter change. Jacket water capacity is 170 L (44.9 gal); total radiator system capacity is 367 L (96.9 gal). Four 1,150 CCA batteries power dual 24V starter motors (dual 24V configuration).

Common Failure Modes#

Fuel injection pump and injector wear is the primary concern at high service hours on the Mitsubishi S16R platform, typically around 10,000 hours. The V16 cylinder arrangement requires attention to individual injector balance to prevent uneven cylinder loading; symptoms include hard starting and visible black smoke.

Turbocharger degradation manifests around 12,000 hours. The 1750REOZMD dissipates significant heat (162 kW to ambient from the engine alone); turbocharger oil supply lines and bearing clearances should be inspected at extended service intervals.

Cooling system components — hoses, thermostat, and water pump — are subject to wear given the 367 L system capacity and dual-circuit cooling (engine jacket water plus charge intercooler circuit). Annual hose inspection and coolant testing are required for NFPA 110 compliance.

Starting battery condition is critical on large displacement V16 engines. The four-battery configuration maintains adequate cranking current, but individual battery health testing at each annual inspection prevents surprise failures during exercise tests.

Our service experience#

OnPoint Generators provides installation, maintenance, load bank testing, and emergency service for Kohler industrial generators throughout Northern California and the Central Valley. The 1750REOZMD is one of the largest generators we service in the Bay Area's hospital and data center corridor. Accounts in this power class require 1 MW+ load banks for full-rated testing and certified medium-voltage technicians for switchgear work. We maintain OEM relationships with both Kohler/Rehlko and Mitsubishi's industrial engine division to support these installations.

FAQ#

Q: What engine powers the Kohler 1750REOZMD? A: The 1750REOZMD uses a Mitsubishi S16R-Y2PTAW2-1 — a 65.4 L, 16-cylinder V-configuration turbocharged diesel at 1800 RPM, EPA Tier 2 certified for stationary emergency standby.

Q: What is the standby power rating of the 1750REOZMD? A: 1,780 kW standby and 1,650 kW prime at 0.8 power factor per Kohler spec sheet G5-368.

Q: What medium-voltage options are available? A: The 1750REOZMD supports 4,160V, 12,470V, 13,200V, and 13,800V medium-voltage outputs through the 7M4370 and 7M4374 alternator options, enabling direct connection to medium-voltage distribution buses.

Q: Does OnPoint service the Kohler 1750REOZMD? A: Yes. OnPoint Generators provides maintenance, repair, and full-load bank testing for Kohler REOZMD diesel generators throughout Northern California, including the 1,780 kW class.

Engineering specifications

Physical

Wet weight
34,000 lb

Fuel system & runtime

Fuel use @ full load
141.6 GPH
Fuel use @ 75% load
106.6 GPH
Fuel use @ 50% load
71.6 GPH

Photos

Kohler 1750REOZMD — product photo

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Kohler 1750REOZMD

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Kohler 1750REOZMD

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

1.8 hours(0.1 days)

Fuel consumption ≈ 109.23 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Kohler 1750REOZMD under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel injection pump / injectorsHard starting, black smoke, uneven cylinder loading10,000+moderate
TurbochargerPower loss, excessive exhaust smoke, oil carryover12,000+moderate
Cooling system (hoses / thermostat)Overtemperature fault, coolant loss10,000+minor
Battery (starting)Slow crank, failed exercise8,760+minor

Frequently Asked Questions

What engine powers the Kohler 1750REOZMD?
The 1750REOZMD uses a Mitsubishi diesel engine running at 1800 RPM (model S16R-Y2PTAW2-1).
What is the standby power rating of the 1750REOZMD?
The 1750REOZMD is rated at 1780 kW standby and 1650 kW prime per Kohler published specifications.
Does OnPoint service the Kohler 1750REOZMD?
Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 1780 kW class.

Compatible equipment

More in the REOZ Series (Diesel Industrial Large)

Kohler REOZ large industrial diesel gensets from 515 to 2500 kW with Mitsubishi, MTU, and Volvo engines.

Similar models

Kohler Kohler 2000ROZMC 1.8 MW liquid-cooled standby generator

Kohler

Kohler 2000ROZMC

1760 kW industrial diesel -- Mitsubishi S16R V16 turbo with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.

1.8 MW standby · Diesel · Liquid-cooled

1760 kW diesel 1500 RPM non-certified industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

3-phasedata-centerhealthcare
Kohler Kohler 2000REOZMD 2 MW liquid-cooled standby generator

Kohler

Kohler 2000REOZMD

2000 kW industrial diesel -- Mitsubishi S16R-Y2PTAW2-1 with Decision-Maker 6000 paralleling. Sub-3% THD, UL 2200, NFPA 110 Level 1.

2 MW standby · Diesel · Liquid-cooled

2000 kW diesel industrial generator powered by Mitsubishi. Mission-critical standby for data centers, hospitals, and large commercial facilities.

Tier 23-phasedata-centerhealthcare
Kohler Kohler KD1750 1.8 MW liquid-cooled standby generator

Kohler

Kohler KD1750

Megawatt-class KD at 1750 kW -- Kohler KD45V20, sub-3% THD, Decision-Maker 6000 paralleling controller.

1.8 MW standby · Diesel · Liquid-cooled

1750 kW diesel industrial standby generator. KD Series platform for data centers, healthcare, and mission-critical infrastructure.

Tier 23-phasedata-centerhealthcare

Need service or parts for the Kohler 1750REOZMD?

We service every major OEM and stock genuine parts for the most common models.