Gillette · SP Series (Commercial Gas Standby)

New

Gillette SP-410

40 kW standby · Natural Gas / LPG · Liquid-cooled

40 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 4.3L V6 engine, Stamford alternator, and DSE 7420 MKII controller.

Gillette SP-410 — product photo
Standby power
40 kW
Voltage options
120/240V, 120/208V, 277/480V, 346/600V
Frequency / Phase
60 Hz · 1/3-phase
Engine
PSI 4.3L V6 · 4.3L
EPA / Emissions
EPA Stationary Spark Ignition
Alternator
Stamford UCI224D
commercialrestaurantretailmulti-familysmall-office

Overview#

The Gillette SP-410 is a 40-kilowatt natural gas (41 kW on LPG) standby generator designed for mid-range commercial applications: restaurants, retail buildings, multi-family residential complexes, and small offices that need whole-building backup power on piped natural gas. At 40 kW, this unit comfortably handles HVAC systems, commercial kitchen equipment, lighting, and essential building loads during an outage.

Like all Gillette SP Series generators, the SP-410 is built with industry-standard name-brand components: a PSI 4.3L V6 engine, Stamford UCI224D alternator, and Deep Sea Electronics DSE 7420 MKII controller. Every unit is assembled and 100% load-tested at Gillette's facility in Elkhart, Indiana. For Northern California commercial customers who prefer non-proprietary parts and open-architecture serviceability, the SP-410 fills the 40 kW gap between smaller residential-class generators and larger commercial units.

The PSI engine platform#

The SP-410 is powered by PSI's 4.3-liter naturally aspirated V6 engine — 262 cubic inches of displacement from six cylinders in a 90-degree vee configuration. This is a purpose-built industrial gas engine, not a converted automotive or diesel block. PSI designed the 4.3L specifically for stationary generator duty on natural gas and LP fuel.

The engine features an electronic governor with isochronous frequency regulation (1/4% steady-state), delivering 62 brake horsepower on natural gas at 1800 RPM — well-matched to the 40 kW generator output with reserve capacity for transient loading. Electronic fuel injection maintains a consistent air-fuel ratio across the load range, and the engine is catalytic converter compatible for sites requiring additional emissions control. Compared to Kohler's proprietary engine platforms at similar kW, the PSI V6 offers the advantage of open-market parts availability through industrial distributors.

Our service experience#

We service PSI engines across multiple generator brands in our territory, and the 4.3L V6 is a well-known platform. The DSE 7420 MKII controller is identical to what we see on many other commercial generator brands — no proprietary software, no dealer-locked diagnostics, and freely downloadable configuration software from the DSE website.

Parts availability in Northern California is solid for the PSI and Stamford components, both available through industrial distributors. Common consumables (spark plugs, oil filters, air filters) cross-reference to widely available part numbers. There is no local Gillette dealer in our area, so we recommend customers keep critical spares on-site: a set of spark plugs, oil filters, and a replacement battery. The 40 kW class hits a sweet spot for many commercial buildings, and the SP-410's open-component architecture ensures you are never locked into a single service provider for the life of the unit.

Engineering specifications

Physical

Length
94 in
Width
42 in
Height
53 in
Wet weight
1,771 lb

Acoustic

Sound @ 7m, full load
64 dBA
Enclosure
Sound-attenuated

Fuel system & runtime

BTU/hr @ full load
584,000

Certifications & compliance

  • NFPA 110 / Level 1 / Type 10
  • UL 2200

Photos

Gillette SP-410 — product photo

Documents & downloads

Permit submittal package

AHJs typically request these documents bundled. Click each to download individually, or use the bundle button to download the full package.

Request a quote

Get pricing & lead time on the Gillette SP-410

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Gillette SP-410

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Fuel demand at 75% load

420,000 BTU/hr420.0 cf/min @ 1,000 BTU/cf

On utility natural gas the runtime is generally unlimited provided the supply line and meter can deliver this BTU/hr at the engine's required inlet pressure (typically 5–14" WC residential, up to 5 psi commercial). Confirm against the OEM's published fuel-pressure spec.

Service intervals

Manufacturer-recommended intervals for the Gillette SP-410 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 250 hours or 12 months
Coolant change
Every 4000 hours
Air filter
Every 1000 hours
Spark plugs
Every 1500 hours
Major overhaul
15,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Spark plugs / ignitionMisfire under load, hard starting1,500+minor
BatteryFailed to start during outage8,760+minor
Coolant systemOvertemp, coolant loss6,000+minor

Frequently Asked Questions

How does the SP-410 compare to a Kohler 38RCL at similar kW?
Both are in the 38-41 kW natural gas standby class at 1800 RPM. The Kohler 38RCL uses Kohler's proprietary controller and engine platform, while the Gillette SP-410 uses a PSI 4.3L V6 engine with a Stamford UCI224D alternator and DSE 7420 MKII controller. Gillette's open-architecture approach means any qualified technician can service it without dealer-specific software, though Kohler has a larger local parts and service network in Northern California.
Is the SP-410 NFPA 110 Level 1 compliant?
Yes — the SP-410 is UL 2200 listed and configurable for NFPA 110 Level 1 when supplied with the required alarm contacts, battery monitoring, and fuel supply provisions.
What controller does the SP-410 use?
Deep Sea Electronics DSE 7420 MKII — an industry-standard auto mains failure controller with Modbus communication, digital metering, event logging, and remote monitoring capability.

Compatible equipment

Similar models

Gillette SP-250 backup generator

Gillette

New

Gillette SP-250

25 kW standby · Natural Gas / LPG · Liquid-cooled

25 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 2.4L inline-4 engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialrestaurant
Gillette SP-620 backup generator

Gillette

New

Gillette SP-620

60 kW standby · Natural Gas / LPG · Liquid-cooled

60 kW natural gas standby generator. Made-in-USA commercial gaseous unit with PSI 5.7L V8 engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialrestaurant

Gillette

New

Gillette PR-800

80 kW standby · Natural Gas / LPG · Liquid-cooled

80 kW prime-rated natural gas / LPG generator. PSI 8.8L V8 naturally aspirated, Stamford UCI274 alternator, DSE 7420 MKII. Continuous duty. Made in USA.

EPA Stationary Spark Ignition3-phaseprime-powerremote-site

Gillette

New

Gillette SP-960

96 kW standby · Natural Gas / LPG · Liquid-cooled

96 kW natural gas / 80 kW LPG stationary standby generator. Made-in-USA commercial gaseous unit with PSI engine, Stamford alternator, and DSE 7420 MKII controller.

EPA Stationary Spark Ignition3-phasecommercialrestaurant

Blue Star Power Systems

New

Blue Star PS40-01

40 kW standby · Natural Gas / LPG · Liquid-cooled

40 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 4.3L six-cylinder naturally aspirated V6 engine, Stamford UCI224C alternator, DSE DCP7310 controller, 208-600V output.

EPA Stationary Spark Ignition3-phasecommerciallight-commercial

Blue Star Power Systems

New

Blue Star PS40-01P

40 kW standby · Natural Gas / LPG · Liquid-cooled

35 kW prime / 40 kW standby natural gas / LP generator from Blue Star Power Systems. PSI 4.3L six-cylinder V6 engine with catalyst/silencer, Stamford UCI224C alternator, DSE DCP7310 controller, 208-600V output.

EPA Stationary Spark Ignition3-phasecommerciallight-commercial

Need service or parts for the Gillette SP-410?

We service every major OEM and stock genuine parts for the most common models.