Blue Star Power Systems · Diesel Product Line (Perkins)

New

Blue Star PD150-01

150 kW standby · Diesel · Liquid-cooled

150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, Stamford UCI274F alternator, DSE DCP7310 controller.

Standby power
150 kW
Voltage options
120/240V, 120/208V, 277/480V, 347/600V
Frequency / Phase
60 Hz · 1/3-phase
Engine
Perkins 1106D-E70TAG2 · 7.01L
EPA / Emissions
Tier 3
Alternator
Stamford UCI274F
light-commercialcommerciallight-industrialmulti-familyworshipmunicipaltelecompump-station

Overview#

The Blue Star PD150-01 is a 150-kilowatt Tier 3 diesel standby generator powered by the Perkins 1106D-E70TAG2, a 7.01-liter six-cylinder electronically injected turbocharged and charge-air-cooled engine at its rated peak output. It shares the 110×54 in equipment pad with the PD125-01 — meaning sites that can accept a 125 kW unit can accept a 150 kW unit without equipment room modifications.

Blue Star Power Systems (North Mankato, Minnesota) pairs the 1106D-E70TAG2 with a Stamford UCI274F alternator and DSE DCP7310 controller. At 3,775 lbs, the PD150-01 is only 75 lbs heavier than the PD125-01, with the weight difference attributable to the larger UCI274F alternator frame. Both models produce 85 dBA at 7 meters full load and share identical exhaust and airflow specifications.

The 1106D-E70TAG2 at 150 kWe#

At 150 kWe, the 1106D-E70TAG2 is running near its rated standby ceiling for this configuration. The step from 125 to 150 kWe is delivered through a higher-rated alternator rather than any engine calibration change — the TAG2 suffix engine is identical between PD125 and PD150. This means the engine thermal loading difference between the two models is marginal, and the 842°F exhaust temperature profile is the same. Sites that need 150 kW today but may need less tomorrow will find the engine runs well at partial load.

When to spec the PD150-01#

Our service experience#

At 150 kWe, the 1106D-E70TAG2 is working at peak rated output. Load bank testing at commissioning and each annual service verifies the unit can pick up the full connected load. Fuel consumption at 75% load (9.30 gph) is efficient relative to full load (11.2 gph). The 842°F exhaust temperature is manageable; use Blue Star's critical grade silencer and ensure adequate clearance from combustibles. Follow the Perkins 1100D generator series service schedule.

Engineering specifications

Physical

Length
110 in
Width
54 in
Height
65 in
Dry weight
3,775 lb

Acoustic

Sound @ 7m, full load
85 dBA
Enclosure
Open

Fuel system & runtime

Fuel use @ full load
11.2 GPH
Fuel use @ 75% load
9.3 GPH
Fuel use @ 50% load
6.61 GPH

Thermal & ventilation

Heat to coolant
256,800 BTU/hr
Heat radiated
182,820 BTU/hr
Exhaust flow
1,057 CFM
Exhaust temp
842 °F
Combustion air
509 CFM
Ventilation air
7,173 CFM

Documents & downloads

Spec sheets & manuals

Request a quote

Get pricing & lead time on the Blue Star PD150-01

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Blue Star PD150-01

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

23.1 hours(1.0 days)

Fuel consumption ≈ 8.64 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Blue Star PD150-01 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel quality / degradationHard starting, filter clogging, reduced power4,380+moderate
TurbochargerPower loss, excessive smoke under load12,000+moderate
BatteryFailed to start, slow crank8,760+minor

Frequently Asked Questions

What engine does the PD150-01 use?
The Perkins 1106D-E70TAG2 — a 7.01-liter, six-cylinder electronically injected turbocharged and charge-air-cooled diesel rated for this 150 kWe standby application. This is the same engine used in the PD125-01 at a lower output rating; at 150 kWe the engine operates closer to its peak capacity. It is EPA Tier 3 certified for stationary emergency use. Rated power is available up to 3,281 ft (1,000 m) at ambient temperatures to 86°F (30°C).
What controller does the PD150-01 use?
The DSE DCP7310 Digital Control Panel, with CAN Bus J1939 engine communication, digital metering, RS-485 interface, 8 programmable contact inputs, 10 contact outputs, and NFPA 110 Level 1 compatibility. It is cULus Listed and CE Approved with IP 65 ingress protection (with supplied gasket).
How does the PD150-01 compare to the PD125-01 and PD180-01?
The PD125-01 and PD150-01 share the same 1106D-E70TAG2 engine and 110×54 in footprint. The PD150-01 uses a larger UCI274F alternator (vs UCI274E) and weighs 75 lbs more (3,775 vs 3,700 lbs). Full-load fuel: 9.58 gph (PD125) vs 11.2 gph (PD150). The PD180-01 steps up to the higher-output 1106D-E70TAG4 engine at 180 kWe on the same 110×54 in footprint, with a UCI274G alternator (3,925 lbs, 13.2 gph).
What are the ventilation requirements for an indoor PD150-01 installation?
The PD150-01 requires 7,173 CFM of radiator cooling airflow and 509 CFM combustion air — identical airflow to the PD125-01, since the engine is the same. Heat radiated to ambient is 182,820 BTU/hr; the coolant circuit rejects 256,800 BTU/hr. Exhaust exits at 842°F at 1,057 CFM. For fuel planning: at full load (11.2 gph), a 500-gallon tank provides approximately 44 hours of runtime; a 1,000-gallon tank provides 89 hours.

Compatible equipment

Similar models

Blue Star Power Systems

New

Blue Star PD125-01

125 kW standby · Diesel · Liquid-cooled

125 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, Stamford UCI274E alternator, DSE DCP7310 controller.

Tier 33-phaselight-commercialcommercial

Blue Star Power Systems

New

Blue Star PD180-01

180 kW standby · Diesel · Liquid-cooled

180 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG4 six-cylinder engine with charge air cooling, Stamford UCI274G alternator, DSE DCP7310 controller.

Tier 33-phaselight-commercialcommercial

Blue Star Power Systems

New

Blue Star JD150-01

150 kW standby · Diesel · Liquid-cooled

150 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 6068HF285 6-cylinder engine, Stamford UCI274/UCDI274 alternator, DSE DCP7310 controller.

Tier 33-phaselight-commercialcommercial

Blue Star Power Systems

New

Blue Star VD150-04FT4

150 kW standby · Diesel · Liquid-cooled

150 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD881VE 7.7L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.

Tier 4 Final3-phasecommerciallarge-commercial

Blue Star Power Systems

New

Blue Star VD150-04FT4MP

150 kW standby · Diesel · Liquid-cooled

150 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD881VE six-cylinder engine, Stamford UCI274F alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.

Tier 4 Final3-phaseconstructiontemporary-power

Blue Star Power Systems

New

Blue Star VD125-02FT4

125 kW standby · Diesel · Liquid-cooled

125 kW Tier 4 Final diesel standby generator from Blue Star Power Systems. Volvo Penta TAD572VE engine with charge-air cooling, paired with Basler DGC-2020 controller.

Tier 4 Final3-phasecommerciallight-industrial