Blue Star Power Systems · Diesel Product Line (Perkins)

New

Blue Star PD100-01

100 kW standby · Diesel · Liquid-cooled

100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TAG2 turbocharged intercooled engine, Stamford UCI274C alternator, DSE DCP7310 controller.

Standby power
100 kW
Voltage options
120/240V, 120/208V, 277/480V, 347/600V
Frequency / Phase
60 Hz · 1/3-phase
Engine
Perkins 1104D-E44TAG2 · 4.4L
EPA / Emissions
Tier 3
Alternator
Stamford UCI274C
light-commercialcommerciallight-industrialmulti-familyworshipmunicipaltelecompump-station

Overview#

The Blue Star PD100-01 is a 100-kilowatt Tier 3 diesel standby generator powered by the Perkins 1104D-E44TAG2, a 4.4-liter electronically injected turbocharged and charge-air-cooled four-cylinder engine — pushed to its peak standby output. It shares the 90×44 in equipment pad with the PD80-01, making it a direct power upgrade for sites where 80 kW is insufficient.

Blue Star Power Systems (North Mankato, Minnesota) pairs the 1104D-E44TAG2 with a Stamford UCI274C alternator (stepping up from the UCI224 frame to the 274 frame) and DSE DCP7310 controller. At 2,500 lbs, the PD100-01 is only 75 lbs heavier than the PD80-01, meaning equipment rooms designed for either model can accept the other without structural modification.

The 1104D-E44TAG2 at Peak Output#

At 100 kWe, the 1104D-E44TAG2 is running at its peak rated standby capacity for this configuration. The engine's thermal profile is identical to the PD80-01 — same coolant heat rejection, same exhaust conditions — because the added load is absorbed by the larger alternator rather than increased engine output. This means the 100 kWe rating is achieved through a higher-rated generator rather than a fundamentally different engine calibration, and the engine service experience mirrors the PD80-01 closely.

When to spec the PD100-01#

Our service experience#

Because the PD100-01 runs the 1104D-E44TAG2 near its peak output, we recommend load bank testing at commissioning and at each annual service. Fuel consumption at 75% load (6.24 gph) compared to full load (7.64 gph) shows good load efficiency; the unit performs well at partial load. Follow the Perkins 1100D generator series service schedule and inspect the intercooler connections annually.

Engineering specifications

Physical

Length
90 in
Width
44 in
Height
60 in
Dry weight
2,500 lb

Acoustic

Sound @ 7m, full load
82 dBA
Enclosure
Open

Fuel system & runtime

Fuel use @ full load
7.64 GPH
Fuel use @ 75% load
6.24 GPH
Fuel use @ 50% load
4.59 GPH

Thermal & ventilation

Heat to coolant
188,220 BTU/hr
Heat radiated
124,560 BTU/hr
Exhaust flow
714 CFM
Exhaust temp
1218 °F
Combustion air
312 CFM
Ventilation air
7,703 CFM

Documents & downloads

Spec sheets & manuals

Request a quote

Get pricing & lead time on the Blue Star PD100-01

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Blue Star PD100-01

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

33.9 hours(1.4 days)

Fuel consumption ≈ 5.89 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Blue Star PD100-01 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel quality / degradationHard starting, filter clogging, reduced power4,380+moderate
TurbochargerPower loss, excessive smoke under load12,000+moderate
BatteryFailed to start, slow crank8,760+minor

Frequently Asked Questions

What engine does the PD100-01 use?
The Perkins 1104D-E44TAG2 — a 4.4-liter, four-cylinder electronically injected turbocharged and charge-air-cooled diesel rated for this 100 kWe standby application. This is the same engine used in the PD80-01 at a higher output rating, operating closer to its peak mechanical capability. The PD100-01 uses a larger Stamford UCI274C alternator (274 frame) compared to the UCI224G in the PD80-01. It is EPA Tier 3 certified for stationary emergency use. Rated power is available up to 3,281 ft (1,000 m) at ambient temperatures to 122°F (50°C).
What controller does the PD100-01 use?
The DSE DCP7310 Digital Control Panel, with CAN Bus J1939 engine communication, digital metering, RS-485 interface, 8 programmable contact inputs, 10 contact outputs, and NFPA 110 Level 1 compatibility. It is cULus Listed and CE Approved with IP 65 ingress protection (with supplied gasket).
How does the PD100-01 compare to the PD80-01 and PD125-01?
The PD80-01 and PD100-01 both use the 1104D-E44TAG2 on the same 90×44 in skid — the PD100-01 produces 100 kWe vs 80 kWe through a higher-rated UCI274C alternator (2,500 lbs vs 2,425 lbs). The engine's heat rejection profile is identical between the two: 188,220 BTU/hr to coolant, 714 CFM exhaust at 1,218°F. The PD125-01 moves to the 6-cylinder 7.01-liter 1106D-E70TAG2 platform on a larger 110×54 in footprint (3,700 lbs, 9.58 gph full load).
What are the ventilation requirements for an indoor PD100-01 installation?
The PD100-01 requires 7,703 CFM of radiator cooling airflow — notably higher than the PD80-01 (6,502 CFM) despite sharing the same engine, due to the higher connected load. Combustion air requirement is 312 CFM. Heat radiated to ambient is 124,560 BTU/hr; the coolant circuit rejects 188,220 BTU/hr. Exhaust exits at 1,218°F at 714 CFM. For fuel planning: at full load (7.64 gph), a 500-gallon tank provides approximately 65 hours of runtime.

Compatible equipment

Similar models

Blue Star Power Systems

New

Blue Star PD80-01

80 kW standby · Diesel · Liquid-cooled

80 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1104D-E44TAG2 turbocharged intercooled engine, Stamford UCI224G alternator, DSE DCP7310 controller.

Tier 33-phaselight-commercialcommercial

Blue Star Power Systems

New

Blue Star PD125-01

125 kW standby · Diesel · Liquid-cooled

125 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 1106D-E70TAG2 six-cylinder engine with charge air cooling, Stamford UCI274E alternator, DSE DCP7310 controller.

Tier 33-phaselight-commercialcommercial

Blue Star Power Systems

New

Blue Star JD100-01

100 kW standby · Diesel · Liquid-cooled

100 kW Tier 3 diesel standby generator built by Blue Star Power Systems. John Deere 4045HF285 engine with charge air cooling, Stamford UCI274 alternator, DSE DCP7310 controller.

Tier 33-phaselight-commercialcommercial

Blue Star Power Systems

New

Blue Star VD100-04FT4

100 kW standby · Diesel · Liquid-cooled

100 kW Tier 4 Final diesel standby/prime generator from Blue Star Power Systems. Volvo Penta TAD581VE 5.13L inline-four with SCR/DPF/DOC, DSE DCP7310 controller, 208-600V.

Tier 4 Final3-phasecommercialsmall-commercial

Blue Star Power Systems

New

Blue Star VD100-04FT4MP

100 kW standby · Diesel · Liquid-cooled

100 kW Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TAD581VE four-cylinder engine, Stamford UCI274D alternator, DSE DCP7310 controller, 250-gallon integrated fuel tank.

Tier 4 Final3-phaseconstructiontemporary-power

Blue Star Power Systems

New

Blue Star VD125-02FT4

125 kW standby · Diesel · Liquid-cooled

125 kW Tier 4 Final diesel standby generator from Blue Star Power Systems. Volvo Penta TAD572VE engine with charge-air cooling, paired with Basler DGC-2020 controller.

Tier 4 Final3-phasecommerciallight-industrial

Need service or parts for the Blue Star PD100-01?

We service every major OEM and stock genuine parts for the most common models.