MTU 6R0113 DS200

200 kW standby · Diesel · Liquid-cooled

200 kW EPA Tier 3 diesel standby generator with John Deere 6068HFG85 engine, 6.8 L turbocharged 6-cylinder inline, JDEC electronic isochronous governor, 1800 rpm.

Standby power
200 kW
Voltage options
120/240V, 120/208V, 277/480V, 347/600V
Frequency / Phase
60 Hz · 1/3-phase
Engine
John Deere 6068HFG85 · 6.8L
EPA / Emissions
Tier 3
Commerciallight-industrialhealthcare-standbydata-center-edge
Configure & QuoteDownload spec sheet

Overview#

The MTU 6R0113 DS200 is a 200 kW EPA Tier 3 certified diesel standby generator set built on the John Deere 6068HFG85 — a 6.8-liter, 6-cylinder turbocharged and air-to-air aftercooled diesel producing up to 235 kWm gross. The DS200 is the highest-rated model in the MTU R-series inline engine lineup, extracting maximum output from the 6.8L John Deere platform through a more aggressive turbocharging calibration than the DS150.

The 6068HFG85 uses the John Deere Electronic Control Unit (JDEC) with SAE J1939 communication, electronic isochronous governing at ±0.25% speed regulation, and real-time engine parameter monitoring. Standard equipment includes a unit-mounted radiator rated for 50°C ambient, 12V electric start, and the MTU digital control panel with NFPA 110 compatibility.

The 6R0113 DS200 is EPA Tier 3 and SCAQMD certified. Optional UL 2200 listing, IBC seismic certification, and OSHPD pre-approval are available, making this unit well suited to healthcare and mission-critical applications.

Technical Specifications#

Power Ratings (60 Hz, 1800 rpm)

RatingkWkVA
Standby (ESP)200250

Engine — John Deere 6068HFG85

ParameterValue
Displacement6.8 L (415 in³)
Configuration6-cylinder inline
AspirationTurbocharged and air-to-air aftercooled
Rated speed1800 rpm
GovernorJDEC electronic isochronous, ±0.25%
Max gross power235 kWm (315 bhp)
EmissionsEPA Tier 3, SCAQMD certified
Starting12V electric, 925 CCA

Fuel Consumption (60 Hz standby)

LoadConsumption
100% load15.5 gph (58.6 L/hr)
75% load11.3 gph (42.9 L/hr)
50% load7.9 gph (30 L/hr)

Physical (Open Power Unit)

DimensionValue
Length2,845 mm (112 in)
Width1,219 mm (48 in)
Height1,346 mm (53 in)
Dry weight1,573–2,262 kg (3,469–4,986 lb)

Cooling System

ParameterValue
Radiator ambient rating50°C (122°F)
Water pump capacity265 L/min (70 gpm)
Heat rejection to coolant94.9 kW
Heat rejection to aftercooler57 kW

Our Service Experience#

The DS200 shares the 6068 block with the DS150 but operates at higher specific output — the 6068HFG85 produces 235 kWm versus the DS150's 177 kWm from identical displacement. This means more heat per unit displacement and correspondingly greater attention required to cooling system health. The larger charge cooler on the DS200 carries proportionally higher heat rejection to the aftercooler (57 kW versus 32 kW), and this cooler must be inspected for fin blockage and end cap integrity at every annual service.

Turbocharger health is particularly important at the DS200 output level. Sustained low-load operation (wet stacking) accelerates bearing contamination. If this unit is deployed on a lightly loaded feeder and sees fewer than 30% average load, consider a monthly full-load test run to clear accumulated carbon and verify turbo boost pressure.

Frequently Asked Questions#

How does the DS200 differ from the DS150? Both use the John Deere 6068 block, but the DS200 uses the higher-calibrated 6068HFG85 producing 235 kWm versus the DS150's 6068HF285 at 177 kWm. The DS200 has a larger water pump (265 vs. 180 L/min) and substantially more heat rejection to the aftercooler (57 vs. 32 kW), reflecting its more aggressive output extraction.

What is the fuel tank capacity for extended runtime? The open power unit does not include a sub-base tank as standard. A 500-gallon external tank provides approximately 32 hours of runtime at 100% standby load (15.5 gph consumption).

Is the DS200 suitable for NFPA 110 Level 1 applications? Yes. The DS200 accepts full rated load in a single step per NFPA 110, and is available with optional IBC seismic certification and OSHPD pre-approval for healthcare applications.

What voltages are supported? Three-phase configurations at 120/208V, 120/240V, 277/480V, and 347/600V; also available in 120/240V single-phase.

What warranty does the DS200 carry? Standard 2-year factory warranty. Extended service agreements are available through MTU Onsite Energy authorized distributors.#

Engineering specifications

Physical

Length
112 in
Width
48 in
Height
53 in
Dry weight
3,469 lb

Fuel system & runtime

Fuel use @ full load
15.5 GPH
Fuel use @ 75% load
11.3 GPH
Fuel use @ 50% load
7.9 GPH

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your MTU 6R0113 DS200

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the MTU 6R0113 DS200

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

16.7 hours(0.7 days)

Fuel consumption ≈ 11.96 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the MTU 6R0113 DS200 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 250 hours
Major overhaul
20,000 hours

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
High-output turbochargerTurbo bearing failure from oil contamination or prolonged low-load operation; blue smoke, power losssevere
Air-to-air charge coolerCoolant in intake, white smoke, hydrostatic lock risk — inspect end caps at each servicesevere
Fuel injectorsRough idle, uneven power delivery, excessive black smoke under loadmoderate

Frequently Asked Questions

How does the DS200 differ from the DS150?
Both use the John Deere 6068 block, but the DS200 uses the higher-calibrated 6068HFG85 producing 235 kWm versus the DS150's 6068HF285 at 177 kWm. The DS200 has a larger water pump (265 vs. 180 L/min) and substantially more heat rejection to the aftercooler (57 vs. 32 kW), reflecting its more aggressive output extraction.
What is the fuel tank capacity for extended runtime on the DS200?
The open power unit does not include a sub-base tank as standard. A 500-gallon external tank provides approximately 32 hours of runtime at 100% standby load (15.5 gph consumption).
Is the DS200 suitable for NFPA 110 Level 1 applications?
Yes. The DS200 accepts full rated load in a single step per NFPA 110, and is available with optional IBC seismic certification and OSHPD pre-approval for healthcare applications.
What voltages are supported on the DS200?
Three-phase configurations at 120/208V, 120/240V, 277/480V, and 347/600V; also available in 120/240V single-phase.
What warranty does the DS200 carry?
Standard 2-year factory warranty. Extended service agreements are available through MTU Onsite Energy authorized distributors.
What additional maintenance does the DS200 require versus the DS150?
The DS200's higher specific output means more heat per unit displacement. The larger charge cooler (57 kW vs 32 kW aftercooler rejection) must be inspected for fin blockage and end cap integrity at every annual service. Sustained low-load operation can accelerate turbocharger wear — monthly full-load test runs are recommended for lightly loaded feeders.

Compatible equipment

Similar models

MTU

MTU 6R0113 DS150

150 kW diesel standby on JD 6068HF285 inline-6. Smoother vibration than 4-cyl alternatives, SCAQMD certified, OSHPD eligible, 11.8 gph.

150 kW standby · Diesel · Liquid-cooled

150 kW EPA Tier 3 diesel standby generator with John Deere 6068HF285 engine, 6.8 L turbocharged-aftercooled 6-cylinder inline, JDEC governor, 1800 rpm.

Tier 33-phasecommercial-standbylight-industrial

MTU

MTU 6R0150 DS250

250 kW diesel standby on JD 6090HF484 9.0L inline-6. Compact 12-ft footprint, 19.6 gph, SCAQMD + Tier 3, under 7,000 lb.

250 kW standby · Diesel · Liquid-cooled

250 kW diesel standby generator. John Deere 6090HF484 9.0L inline-6, EPA Tier 3 + SCAQMD certified. 19.6 gph at full load.

Tier 33-phasecommercial-standbyindustrial
Caterpillar Caterpillar C7 200 kW liquid-cooled standby generator

Caterpillar

Caterpillar C7

200 kW diesel with CAT C7 ACERT inline-6. Best resale value in class. ~200 US dealers. Compact footprint.

200 kW standby · Diesel · Liquid-cooled

The Caterpillar C7.1 ACERT is a 200 kW standby diesel generator with EPA Tier 3 certification. 7.01L inline-6 with MEUI fuel injection. Compact standby power for small commercial and retail applications.

Tier 33-phasecommercial-standbyretail

Need service or parts for the MTU 6R0113 DS200?

We service every major OEM and stock genuine parts for the most common models.