Kohler · REOZ Series (Diesel Commercial Standby)

Kohler 350REOZJC

350 kW standby / 320 kW prime · Diesel · Liquid-cooled

350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Kohler Kohler 350REOZJC generator — specifications and details
Standby power
350 kW / 320 kW prime
Voltage options
277/480V, 120/208V, 120/240V
Frequency / Phase
60 Hz · 1/3-phase
Engine
John Deere 6135HF485T · 13.5L
EPA / Emissions
Tier 3
Alternator
Kohler 4M4019

Overview#

The Kohler 350REOZJC is a 350-kilowatt standby (320 kW prime) diesel generator powered by a John Deere 6135HF485T — a 13.5 L turbocharged charge-air-cooled inline-6 at 1800 RPM. As the successor to the REOZJB in this power class, the JC variant adds prime power ratings and approval for Hydrotreated Vegetable Oil (HVO) / Renewable Diesel (RD) fuels compliant with EN15940 / ASTM D975.

The 350REOZJC is Tier 3 EPA-certified for stationary emergency applications and is UL 2200 listed. Typical deployments include commercial office buildings, healthcare facilities, institutional campuses, and government installations where NFPA 110 Level 1 standby power is required. At 350/320 kW standby/prime, this unit provides reliable power for facilities too large for residential-class equipment but not yet requiring the Volvo-powered REOZVB series above 500 kW.

Support for HVO/RD fuels (with up to 4% higher volumetric consumption than #2 ULSD) makes the 350REOZJC suitable for facilities with sustainability mandates that require lower-carbon standby options without replacing the generator set.

Specifications#

SpecValue
Standby Power350 kW
Prime Power320 kW
Voltage (primary)277/480V three-phase
Frequency60 Hz
EngineJohn Deere 6135HF485T
Engine type4-cycle turbocharged, charge air-cooled
Cylinders6 inline
Displacement13.5 L (824 cu. in.)
Compression ratio16.0:1
Rated RPM1800
AlternatorKohler 4M4019
FuelDiesel (#2 / HVO / RD)
CoolingLiquid (radiator)
Emissions tierEPA Tier 3 stationary emergency
Fuel consumption (100% standby load)26.5 gph
Fuel consumption (75% standby load)19.3 gph
Overall dimensions142.9" x 56.1" x 76.2"
Operating weight8,560 lb

Service & Maintenance#

ServiceInterval
Oil changeEvery 250 hours or 12 months
Fuel filter replacementEvery 500 hours
Air filter replacementEvery 500 hours
Coolant flushEvery 3,000 hours or 5 years
Load bank testAnnually (NFPA 110 requirement)
Major overhaulEvery 15,000 hours

Oil pan capacity is 40.0 L (42.3 qt) dry and 42.0 L (44.4 qt) with filter change. The 6135HF485T uses a single cartridge oil filter with a water-cooled oil cooler. Kohler specifies its Genuine oil and filter line for this engine.

Common Failure Modes#

Fuel quality and degradation is the leading cause of unplanned outages on standby generators at this power level. Diesel stored in day tanks without biocide treatment develops microbial growth and sediment, causing injector fouling, hard starting, and filter blockage — typically appearing around 4,380 hours of service life. Quarterly fuel polishing is standard protocol for NFPA 110 Level 1 accounts.

Turbocharger wear manifests around 12,000 hours. The 6135HF485T is turbocharged and charge air-cooled; turbocharger degradation presents as progressive power loss and increased exhaust smoke under load. John Deere's parts network supports rapid field replacement.

Starting battery failure is the most common cause of failed monthly exercise tests, typically around 8,760 hours. The 350REOZJC requires two 925 CCA 12V batteries in a 24V series configuration. Battery condition testing should be integrated into every NFPA 110 annual inspection.

Our service experience#

OnPoint Generators provides installation, maintenance, load bank testing, and emergency service for Kohler industrial generators throughout Northern California and the Central Valley. For 350REOZJC installations, we maintain fuel treatment programs on a quarterly basis alongside the standard annual NFPA 110 inspection. The John Deere 6135 platform's wide parts availability and documented service procedures allow us to minimize downtime when unplanned repairs are required.

FAQ#

Q: What engine powers the Kohler 350REOZJC? A: The 350REOZJC uses a John Deere 6135HF485T — a 13.5 L, 6-cylinder turbocharged charge-air-cooled diesel at 1800 RPM, rated for Tier 3 stationary emergency standby.

Q: What is the standby power rating of the 350REOZJC? A: 350 kW standby and 320 kW prime at 0.8 power factor per Kohler spec sheet G5-618.

Q: Does the 350REOZJC support renewable diesel fuels? A: Yes. The 350REOZJC is approved for HVO/Renewable Diesel compliant with EN15940/ASTM D975. Expect volumetric fuel consumption approximately 4% higher than with standard #2 ULSD.

Q: Does OnPoint service the Kohler 350REOZJC? A: Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZJ diesel generators throughout Northern California, including the 350 kW class.

Engineering specifications

Physical

Length
142.9 in
Width
56.1 in
Height
76.2 in
Wet weight
8,560 lb

Fuel system & runtime

Fuel use @ full load
26.5 GPH
Fuel use @ 75% load
19.3 GPH
Fuel use @ 50% load
13.7 GPH

Photos

Kohler 350REOZJC — product photo

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Kohler 350REOZJC

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Kohler 350REOZJC

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

9.8 hours(0.4 days)

Fuel consumption ≈ 20.44 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Kohler 350REOZJC under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 250 hours or 12 months
Coolant change
Every 3000 hours
Air filter
Every 500 hours
Fuel filter
Every 500 hours
Major overhaul
15,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel quality / degradationInjector fouling, hard starting, filter clogging4,380+moderate
TurbochargerPower loss, excessive smoke under load12,000+moderate
Battery (starting)Failed to start, slow crank8,760+minor

Frequently Asked Questions

What engine powers the Kohler 350REOZJC?
The 350REOZJC uses a John Deere diesel engine running at 1800 RPM (model 6135HF485T).
What is the standby power rating of the 350REOZJC?
The 350REOZJC is rated at 350 kW standby and 320 kW prime per Kohler published specifications.
Does OnPoint service the Kohler 350REOZJC?
Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 350 kW class.

Compatible equipment

More in the REOZ Series (Diesel Commercial Standby)

Kohler's diesel commercial standby series — 10 to 510 kW, John Deere and Kohler engines, built for life-safety loads.

Similar models

Kohler Kohler 350REOZJ 350 kW liquid-cooled standby generator

Kohler

Kohler 350REOZJ

350 kW diesel standby with sub-3% THD -- John Deere 6135HF485T. Healthcare and data center default in this power class.

350 kW standby · Diesel · Liquid-cooled

350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler Kohler 350REOZJB 360 kW liquid-cooled standby generator

Kohler

Kohler 350REOZJB

360 kW diesel standby with sub-3% THD -- John Deere 6135HFG84B. Healthcare and data center default in this power class.

360 kW standby · Diesel · Liquid-cooled

360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler Kohler 300REOZJ 300 kW liquid-cooled standby generator

Kohler

Kohler 300REOZJ

300 kW diesel standby with sub-3% THD -- John Deere 6090HFG86. Healthcare and data center default in this power class.

300 kW standby · Diesel · Liquid-cooled

300 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare

Need service or parts for the Kohler 350REOZJC?

We service every major OEM and stock genuine parts for the most common models.