Kohler · REOZ Series (Diesel Commercial Standby)

Kohler 350REOZJB

360 kW standby · Diesel · Liquid-cooled

360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Kohler Kohler 350REOZJB generator — specifications and details
Standby power
360 kW
Voltage options
277/480V, 120/208V, 120/240V
Frequency / Phase
60 Hz · 1/3-phase
Engine
John Deere 6135HFG84B · 13.5L
EPA / Emissions
Tier 3
Alternator
Kohler 4M4019

Overview#

The Kohler 350REOZJB is a 360-kilowatt diesel standby generator powered by a John Deere 6135HFG84B — a 13.5 L turbocharged charge-air-cooled inline-6 running at 1800 RPM. This is the Tier 3 EPA-certified variant of Kohler's REOZJ platform, designed for stationary emergency standby duty.

At 360 kW, this unit sits at the upper boundary of the mid-range commercial class. Facilities that use it include community hospitals, mid-size data centers, university buildings, and government installations requiring NFPA 110 Level 1 compliance. The generator set accepts rated load in one step and is factory-built and production-tested by Kohler Co., providing one-source system integration.

The 350REOZJB supports multiple voltage configurations (120/208V, 277/480V, 120/240V single-phase) and is compatible with Kohler's APM402, APM603, and Decision-Maker 6000 paralleling controllers. Paralleling capability supports up to 8 units on an isolated bus with first-on logic, kW/kVAR load sharing, and protective relays — making it suitable for N+1 redundancy arrays at mission-critical sites.

Specifications#

SpecValue
Standby Power360 kW
Voltage (primary)277/480V three-phase
Frequency60 Hz
EngineJohn Deere 6135HFG84B
Engine type4-cycle turbocharged, charge air-cooled
Cylinders6 inline
Displacement13.5 L (824 cu. in.)
Compression ratio16.0:1
Rated RPM1800
AlternatorKohler 4M4019
FuelDiesel (#2 / HVO / RD)
CoolingLiquid (radiator)
Emissions tierEPA Tier 3 stationary emergency
Fuel consumption (100% load)26.5 gph
Fuel consumption (75% load)21.2 gph
Overall dimensions142.9" x 56.1" x 78.5"
Operating weight8,560 lb

Service & Maintenance#

ServiceInterval
Oil changeEvery 250 hours or 12 months
Fuel filter replacementEvery 500 hours
Air filter replacementEvery 500 hours
Coolant flushEvery 3,000 hours or 5 years
Load bank testAnnually (NFPA 110 requirement)
Major overhaulEvery 15,000 hours

The John Deere 6135 uses a water-cooled oil cooler and a single cartridge oil filter. Kohler specifies Kohler Genuine oil and filters. Oil pan capacity is 40.0 L (42.3 qt) dry, 42.0 L (44.4 qt) with filter.

Common Failure Modes#

Fuel quality and degradation is the leading service issue for standby generators in this class, typically manifesting around 4,380 hours (roughly one year of runtime equivalent). Diesel that sits in day tanks without treatment develops microbial contamination and fuel stratification, leading to injector fouling, hard starting, and filter clogging. Quarterly fuel polishing and biocide treatment are standard practice for NFPA 110 Level 1 accounts.

Turbocharger wear typically appears around 12,000 hours under normal operating conditions. Symptoms include progressive power loss, excessive smoke under load, and increased oil consumption. The turbocharger on the 6135 platform is serviceable in the field; replacement turbos are stocked through John Deere's commercial parts network.

Starting battery degradation presents as slow crank or failed exercise at roughly 8,760 hours. The 350REOZJB uses two 925 CCA (12V each) batteries in a 24V configuration. Battery condition testing should be part of every annual NFPA 110 inspection.

Our service experience#

OnPoint Generators provides installation, maintenance, load bank testing, and emergency service for Kohler industrial generators throughout Northern California and the Central Valley. For 360 kW REOZJB installations, we typically structure maintenance programs around annual NFPA 110 Level 1 inspections combined with semi-annual fuel conditioning checks. The John Deere 6135 platform benefits from excellent parts availability and a well-documented service manual, which keeps repair windows short when unplanned issues arise.

FAQ#

Q: What engine powers the Kohler 350REOZJB? A: The 350REOZJB uses a John Deere 6135HFG84B — a 13.5 L, 6-cylinder turbocharged charge-air-cooled diesel at 1800 RPM. This is the Tier 3 stationary emergency variant of the 6135 platform.

Q: What is the standby power rating of the 350REOZJB? A: The 350REOZJB is rated at 360 kW standby at 0.8 power factor per Kohler published specifications (spec sheet G5-402).

Q: Does OnPoint service the Kohler 350REOZJB? A: Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 360 kW class.

Q: What controller options are available for the 350REOZJB? A: Kohler offers the APM402 (digital display, Modbus), APM603 (7-inch touchscreen, paralleling up to 8 units), and Decision-Maker 6000 (advanced paralleling with remote monitoring). For NFPA 110 Level 1 compliance, any of these controllers can be configured appropriately when paired with the required accessories.

Engineering specifications

Physical

Length
142.9 in
Width
56.1 in
Height
78.5 in
Wet weight
8,560 lb

Fuel system & runtime

Fuel use @ full load
26.5 GPH
Fuel use @ 75% load
21.2 GPH
Fuel use @ 50% load
15 GPH

Photos

Kohler 350REOZJB — product photo

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Kohler 350REOZJB

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Kohler 350REOZJB

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

9.8 hours(0.4 days)

Fuel consumption ≈ 20.44 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Kohler 350REOZJB under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 250 hours or 12 months
Coolant change
Every 3000 hours
Air filter
Every 500 hours
Fuel filter
Every 500 hours
Major overhaul
15,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel quality / degradationInjector fouling, hard starting, filter clogging4,380+moderate
TurbochargerPower loss, excessive smoke under load12,000+moderate
Battery (starting)Failed to start, slow crank8,760+minor

Frequently Asked Questions

What engine powers the Kohler 350REOZJB?
The 350REOZJB uses a John Deere diesel engine running at 1800 RPM (model 6135HFG84B).
What is the standby power rating of the 350REOZJB?
The 350REOZJB is rated at 360 kW standby per Kohler published specifications.
Does OnPoint service the Kohler 350REOZJB?
Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 360 kW class.

Compatible equipment

More in the REOZ Series (Diesel Commercial Standby)

Kohler's diesel commercial standby series — 10 to 510 kW, John Deere and Kohler engines, built for life-safety loads.

Similar models

Kohler Kohler 350REOZJD 360 kW liquid-cooled standby generator

Kohler

Kohler 350REOZJD

360 kW diesel standby with sub-3% THD -- John Deere 6135HFG84B. Healthcare and data center default in this power class.

360 kW standby · Diesel · Liquid-cooled

360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler Kohler 350REOZJ 350 kW liquid-cooled standby generator

Kohler

Kohler 350REOZJ

350 kW diesel standby with sub-3% THD -- John Deere 6135HF485T. Healthcare and data center default in this power class.

350 kW standby · Diesel · Liquid-cooled

350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler Kohler 400REOZJ 400 kW liquid-cooled standby generator

Kohler

Kohler 400REOZJ

400 kW diesel standby with sub-3% THD -- John Deere 6135HF485S. Healthcare and data center default in this power class.

400 kW standby · Diesel · Liquid-cooled

400 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare

Need service or parts for the Kohler 350REOZJB?

We service every major OEM and stock genuine parts for the most common models.