Kohler · REOZ Series (Diesel Commercial Standby)

New

Kohler 275REOZJE

280 kW standby / 255 kW prime · Diesel · Liquid-cooled

280 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Kohler 275REOZJE — product photo
Standby power
280 kW / 255 kW prime
Voltage options
277/480V, 120/208V, 120/240V
Frequency / Phase
60 Hz · 1/3-phase
Engine
John Deere 6090HF484A · 9L
EPA / Emissions
Tier 3
Alternator
Kohler 4UA10
commercialhealthcaredata-centerindustrial-lightgovernmentmission-critical

Overview#

The Kohler 275REOZJE is a 280-kilowatt standby (255 kW prime) diesel generator powered by a John Deere engine at 1800 RPM. Typical applications include commercial buildings, healthcare facilities, and institutional campuses.

Our service experience#

OnPoint Generators services Kohler REOZ diesel generators throughout Northern California. We typically structure accounts for mid-range diesel units around annual NFPA 110 service plus semi-annual fuel and filter inspections.

Engineering specifications

Physical

Length
118.1 in
Width
51.2 in
Height
74.4 in
Wet weight
5,400 lb

Fuel system & runtime

Fuel use @ full load
19.6 GPH
Fuel use @ 75% load
15 GPH

Photos

Kohler 275REOZJE — product photo

Documents & downloads

Spec sheets & manuals

Request a quote

Get pricing & lead time on the Kohler 275REOZJE

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Kohler 275REOZJE

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

13.2 hours(0.6 days)

Fuel consumption ≈ 15.12 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Kohler 275REOZJE under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 250 hours or 12 months
Coolant change
Every 3000 hours
Air filter
Every 500 hours
Fuel filter
Every 500 hours
Major overhaul
15,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel quality / degradationInjector fouling, hard starting, filter clogging4,380+moderate
TurbochargerPower loss, excessive smoke under load12,000+moderate
Battery (starting)Failed to start, slow crank8,760+minor

Frequently Asked Questions

What engine powers the Kohler 275REOZJE?
The 275REOZJE uses a John Deere diesel engine running at 1800 RPM (model 6090HF484A).
What is the standby power rating of the 275REOZJE?
The 275REOZJE is rated at 280 kW standby and 255 kW prime per Kohler published specifications.
Does OnPoint service the Kohler 275REOZJE?
Yes. OnPoint Generators provides maintenance, repair, and load bank testing for Kohler REOZ diesel generators throughout Northern California, including the 280 kW class.

Similar models

Kohler 300REOZJ backup generator

Kohler

New

Kohler 300REOZJ

300 kW standby · Diesel · Liquid-cooled

300 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler 250REOZJE backup generator

Kohler

New

Kohler 250REOZJE

255 kW standby · Diesel · Liquid-cooled

255 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler 230REOZJE backup generator

Kohler

New

Kohler 230REOZJE

230 kW standby · Diesel · Liquid-cooled

230 kW diesel commercial standby generator powered by John Deere. Reliable standby power for commercial and institutional facilities.

Tier 33-phasecommercialhealthcare
Kohler 350REOZJ backup generator

Kohler

New

Kohler 350REOZJ

350 kW standby · Diesel · Liquid-cooled

350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler 350REOZJC backup generator

Kohler

New

Kohler 350REOZJC

350 kW standby · Diesel · Liquid-cooled

350 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare
Kohler 350REOZJB backup generator

Kohler

New

Kohler 350REOZJB

360 kW standby · Diesel · Liquid-cooled

360 kW diesel commercial standby generator powered by John Deere. Mid-range diesel workhorse for commercial, healthcare, and institutional applications.

Tier 33-phasecommercialhealthcare

Need service or parts for the Kohler 275REOZJE?

We service every major OEM and stock genuine parts for the most common models.