Hipower Systems · HRNG Series (Mobile Natural Gas)

Hipower HRNG-85

Standby: see spec sheet / 65.6 kW prime · Natural Gas / LPG · Liquid-cooled

65.6 kW prime rental generator set for LPG or natural gas. PSI 8.1 LNA engine, Stamford UCI 224 F alternator.

Hipower Systems Hipower HRNG-85 generator — specifications and details
Standby power
See spec sheet / 65.6 kW prime
Voltage options
120/240V, 120/208V, 277/480V, 347/600V
Frequency / Phase
60 Hz · 1/3-phase
Engine
PSI 8.1 LNA · 5.7L
Alternator
Stamford UCI 224 F
rental-fleetCommercialemergency-temporary
Configure & QuoteDownload spec sheet

Overview#

The Hipower HRNG-85 is a rental gaseous generator set from the PSI HD Gaseous Series. The datasheet lists 65.6 kW (82.0 kVA) prime at 120/208V, 120/240V Delta and 277/480V three-phase on both LPG and natural gas. The engine is a PSI 8.1 LNA.

Power Ratings and Voltages#

Ratings are 60 Hz, as printed on the datasheet:

  • 120/240V single-phase: 42.6 kW (53.3 kVA) prime on LPG and on natural gas, power factor 0.8.
  • 120/208V three-phase: 65.6 kW (82.0 kVA) prime on LPG and on natural gas, power factor 0.8.
  • 120/240V Delta three-phase: 65.6 kW (82.0 kVA) prime on LPG and on natural gas, power factor 0.8.
  • 277/480V three-phase: 65.6 kW (82.0 kVA) prime on LPG and on natural gas, power factor 0.8.
  • 347/600V three-phase: 64.8 kW (81.0 kVA) prime on LPG and on natural gas, power factor 0.8.

PSI Engine Platform#

The 8.1 LNA is a PSI engine with 8 cylinders (arrangement: vee). It is a 4-stroke LPG/NG fueled engine with spark plug ignition and natural aspiration. Cooling is liquid. Displacement is 350 cu in (5.7 liters) at a crankshaft speed of 1,800 rpm. The datasheet lists EPA certified: Yes and a nominal power of LPG 150 hp and NG 146 hp. The alternator is a Stamford UCI 224 F (winding 311 at 120/208V and 277/480V, winding 17 at 600 volts).

Fuel Supply#

Fuel type is natural gas, vapor withdrawal. The fuel supply line inlet is 1.5 in NPTF and the fuel supply pressure is 7 - 11 in. column H2O (1.7 - 2.7 kPa), measured at the gen-set fuel inlet.

Our Service Experience#

OnPoint Generators provides support for Hipower HRNG natural gas generators in Northern California.

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Hipower HRNG-85

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Hipower HRNG-85

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Fuel demand at 75% load

688,800 BTU/hr≈ 688.8 cf/min @ 1,000 BTU/cf

On utility natural gas the runtime is generally unlimited provided the supply line and meter can deliver this BTU/hr at the engine's required inlet pressure (typically 5–14" WC residential, up to 5 psi commercial). Confirm against the OEM's published fuel-pressure spec.

Before you buy this generator

Can a second qualified provider program a replacement controller for the Hipower HRNG-85, using access issued to us?

Ask every supplier to answer in writing. Service access is part of what you are buying.

Open the 13-question checklist

Frequently Asked Questions

What are the power ratings of the HRNG-85?
The datasheet lists prime power ratings on LPG and natural gas. Prime is the rating for both fuels. At 277/480V three-phase it lists 65.6 kW (82.0 kVA) prime on LPG and on natural gas.
What engine powers the HRNG-85?
The datasheet lists a PSI 8.1 LNA: 8 cylinders (arrangement: vee), 4-stroke, LPG/NG fueled with spark plug ignition, natural aspiration and a displacement of 350 cu in (5.7 liters) at 1,800 rpm. It lists EPA certified: Yes and a nominal power of LPG 150 hp and NG 146 hp.
What gas supply pressure is required?
The datasheet lists a fuel supply pressure of 7 - 11 in. column H2O (1.7 - 2.7 kPa), measured at the gen-set fuel inlet, with a 1.5 in NPTF fuel supply line inlet. Fuel type is natural gas, vapor withdrawal.
Who provides HRNG rental and service in Northern California?
Contact OnPoint Generators for information on HRNG rental availability and service in Northern California.

More in the HRNG Series (Mobile Natural Gas)

66 to 940 kW natural gas generators — no on-board fuel, unlimited runtime where gas service exists.

Similar models

Hipower Systems Hipower HRNG-165 liquid-cooled standby generator

Hipower Systems

Hipower HRNG-165

Standby: see spec sheet · Natural Gas / LPG · Liquid-cooled

131 kW prime (natural gas) rental generator set. PSI Heavy Duty 8.1 LT engine, Stamford UCI 274 E N.G. alternator.

3-phaserental-fleetconstruction
Hipower Systems Hipower HGM-65 60 kW liquid-cooled standby generator

Hipower Systems

Hipower HGM-65

60 kW standby · Natural Gas / LPG · Liquid-cooled

60 kW natural gas standby generator set. General Motors Vortec 5.7L engine, Marathon Electric 361PSL1602 alternator.

3-phasecommercial-standbylight-commercial
Hipower Systems Hipower HJW-65 65 kW liquid-cooled standby generator

Hipower Systems

Hipower HJW-65

65 kW standby · Diesel · Liquid-cooled

65 kW diesel standby generator. John Deere 4045HF280-74 engine, Stamford UCI 224 alternator. EPA Tier 3.

Tier 33-phasecommercial-standbylight-commercial

Services for the Hipower HRNG-85

Need service or parts for the Hipower HRNG-85?

We service every major OEM and stock genuine parts for the most common models.