Hipower Systems · HGM Series (Stationary Natural Gas)

Hipower HGM-65

60 kW standby · Natural Gas / LPG · Liquid-cooled

60 kW natural gas standby generator set. General Motors Vortec 5.7L engine, Marathon Electric 361PSL1602 alternator.

Hipower Systems Hipower HGM-65 generator — specifications and details
Standby power
60 kW
Voltage options
120/208V, 120/240V, 277/480V, 347/600V
Frequency / Phase
60 Hz · 3-phase
Engine
General Motors Vortec 5.7L · 5.7L
Alternator
Marathon Electric 361PSL1602

Overview#

The Hipower HGM-65 is a 60 kW (77.5 kVA) natural gas standby generator set at 277/480V three-phase. It pairs a General Motors Vortec 5.7L engine with a Marathon Electric 361PSL1602 alternator. The datasheet states the generator set can accept rated load in one step.

Standby ratings at 60 Hz, as printed on the datasheet:

  • 120/240V single-phase: not available (N.A.).
  • 120/208V three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA).
  • 120/240V Delta three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA).
  • 277/480V three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA).
  • 347/600V three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA).

The 347/600V configuration is not available as a UL2200 certified generator set.

Engine Platform#

The HGM-65 uses a General Motors Vortec 5.7L: 8 cylinders, cylinder arrangement vee, 350 cu in (5.7 liters) displacement, aspiration Natural, liquid cooled, 4-stroke, running at a crankshaft speed of 1,800 rpm. The datasheet lists a nominal power of 100 hp on natural gas and 108 hp on LPG. The alternator is a Marathon Electric 361PSL1602: four-pole, rotating field, with Class H insulation and an SE350 AVR. The datasheet lists alternator model 361PSL1634 for the 600 volt configuration.

Standards#

The datasheet states the generator set is UL2200 and meets ISO 8528-5. It states that the base set meets NFPA 110, when accessorized with the required equipment and installed per NFPA standards. The engine is listed as EPA certified. The 600 volt configuration is not available as a UL2200 certified generator set.

Our Service Experience#

OnPoint Generators maintains natural gas standby generators throughout Northern California.

Engineering specifications

Acoustic

Enclosure
Sound-attenuated

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Hipower HGM-65

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Hipower HGM-65

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Fuel demand at 75% load

630,000 BTU/hr≈ 630.0 cf/min @ 1,000 BTU/cf

On utility natural gas the runtime is generally unlimited provided the supply line and meter can deliver this BTU/hr at the engine's required inlet pressure (typically 5–14" WC residential, up to 5 psi commercial). Confirm against the OEM's published fuel-pressure spec.

Before you buy this generator

Can a second qualified provider program a replacement controller for the Hipower HGM-65, using access issued to us?

Ask every supplier to answer in writing. Service access is part of what you are buying.

Open the 13-question checklist

Frequently Asked Questions

What engine does the HGM-65 use?
The HGM-65 uses a General Motors Vortec 5.7L: 8 cylinders, cylinder arrangement vee, 350 cu in (5.7 liters) displacement, aspiration Natural, liquid cooled, 4-stroke, running at a crankshaft speed of 1,800 rpm. The datasheet lists a nominal power of 100 hp on natural gas and 108 hp on LPG.
What power ratings and voltages are listed for the HGM-65?
The Hipower HGM-65 is a 60 kW (77.5 kVA) natural gas standby generator set at 277/480V three-phase. Standby ratings at 60 Hz, as printed on the datasheet: 120/240V single-phase: not available (N.A.). 120/208V three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA). 120/240V Delta three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA). 277/480V three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA). 347/600V three-phase: standby rating natural gas 60 kW (77.5 kVA); LPG 60 kW (77.5 kVA). The 347/600V configuration is not available as a UL2200 certified generator set.
How much gas does the HGM-65 use?
At 100% of the standby rating the datasheet lists natural gas 800 cu ft/hour (22.6 cu m/hour) and LPG 330 cu ft/hour (9.3 cu m/hour). At 75% of the standby rating the datasheet lists natural gas 695 cu ft/hour (20.0 cu m/hour) and LPG 240 cu ft/hour (7.0 cu m/hour). At 50% of the standby rating the datasheet lists natural gas 500 cu ft/hour (14.2 cu m/hour) and LPG 195 cu ft/hour (5.5 cu m/hour).
What are the dimensions, weight and sound level of the HGM-65?
The datasheet lists the enclosed set at 94.0 x 42.0 x 54.0 in (2388 x 1067 x 1372 mm) L x W x H, net weight 2,395 lb (1086.4 kg), sound level 71 dBA at 23 ft (7 m). The open set is 94.0 x 42.0 x 40.0 in (2388 x 1067 x 1016 mm) L x W x H, net weight 2,022 lb (917.2 kg), sound level listed as TBA. Measurements are approximate and for estimation purposes only, and sound levels do not account for ambient site conditions.
What standards does the HGM-65 meet?
The datasheet states the generator set is UL2200 and meets ISO 8528-5. It states that the base set meets NFPA 110, when accessorized with the required equipment and installed per NFPA standards. The engine is listed as EPA certified. The 600 volt configuration is not available as a UL2200 certified generator set.
Who services HGM generators in Northern California?
OnPoint Generators services Hipower natural gas generators, including HGM series units, throughout Northern California.

Compatible equipment

More in the HGM Series (Stationary Natural Gas)

53 to 150 kW compact natural gas standby — broad voltage support, low-maintenance, and no on-site diesel storage required.

Similar models

Hipower Systems Hipower HGM-80 80 kW liquid-cooled standby generator

Hipower Systems

Hipower HGM-80

80 kW standby · Natural Gas · Liquid-cooled

80 kW natural gas standby generator set. General Motors Vortec 5.7LT engine, Marathon Electric 362CSL1604 alternator.

3-phasecommercial-standbylight-commercial
Hipower Systems Hipower HGM-55 52 kW liquid-cooled standby generator

Hipower Systems

Hipower HGM-55

52 kW standby · Natural Gas / LPG · Liquid-cooled

52 kW natural gas standby generator set. General Motors Vortec 5.7L engine, Marathon Electric 361PSL1601 alternator.

3-phasecommercial-standbylight-commercial
Hipower Systems Hipower HNI-60 60 kW liquid-cooled standby generator

Hipower Systems

Hipower HNI-60

60 kW standby · Natural Gas / LPG · Liquid-cooled

60 kW standby natural gas generator with Origin 3.6L turbocharged engine.

3-phasecommercial-standbylight-commercial

Services for the Hipower HGM-65

Need service or parts for the Hipower HGM-65?

We service every major OEM and stock genuine parts for the most common models.