Gillette · T4D Series (Tier 4 Final Prime Diesel)

New

Gillette T4D-6000

600 kW standby / 570 kW prime · Diesel · Liquid-cooled

600 kW standby / 570 kW prime Tier 4 Final diesel generator with Volvo Penta TWD1683GE 16.1L engine. H2O-to-air aftercooled, SCR+DEF. Gillette's largest T4F unit.

Standby power
600 kW / 570 kW prime
Voltage options
120/208V, 120/240V, 277/480V, 346/600V
Frequency / Phase
60 Hz · 3-phase
Engine
Volvo Penta TWD1683GE · 16.1L
EPA / Emissions
Tier 4 Final
Alternator
Stamford HCI534F-311
data-centerhospitalprime-powerindustrialcampusmunicipal

Overview#

The Gillette T4D-6000 is a 600-kilowatt standby / 570-kilowatt prime Tier 4 Final / Stage V diesel generator — the largest in the T4D series. Volvo's TWD1683GE 16.1L inline-6 with water-to-air aftercooling and SCR aftertreatment. Stamford HCI534F alternator, Basler DGC-2020 controller.

This is the only T4D model with different standby and prime ratings — all smaller T4D models are rated identically for both duty types. The 5% prime derating at 600 kW reflects the engine operating closer to its thermal ceiling.

The TWD1683GE — Tier 4 Final at 16.1L#

The T4D-6000's TWD1683GE is the Tier 4 Final counterpart to the SPVD-6000's TWD1644GE (Tier II). Both are 16.1L inline-6 with water-to-air aftercooling. The Tier 4 Final version adds:

Our service experience#

The T4D-6000 is the most complex diesel service in the Gillette T4D lineup: 16.1L engine, water-to-air aftercooler, SCR catalyst, and DEF system. We approach each service as four subsystems: engine, cooling (dual circuits), fuel, and aftertreatment. Annual full-load testing with emissions verification is standard protocol.

Engineering specifications

Physical

Length
152 in
Width
72 in
Height
116 in
Wet weight
9,625 lb

Acoustic

Sound @ 7m, full load
83 dBA
Enclosure
Sound-attenuated

Fuel system & runtime

Fuel use @ full load
37.2 GPH

Documents & downloads

Spec sheets & manuals

Request a quote

Get pricing & lead time on the Gillette T4D-6000

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Gillette T4D-6000

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

7.0 hours(0.3 days)

Fuel consumption ≈ 28.70 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Gillette T4D-6000 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
DEF system (SCR catalyst)Derate warning, NOx fault, DEF quality alert4,380+moderate
TurbochargerPower loss, excessive smoke12,000+severe
Water-to-air aftercoolerElevated intake temps, reduced output10,000+moderate

Frequently Asked Questions

Is the T4D-6000 the largest Tier 4 Final model Gillette offers?
Yes — at 600 kW standby / 570 kW prime, the T4D-6000 is Gillette's largest Tier 4 Final diesel generator. The Volvo TWD1683GE 16.1L is the largest Tier 4 Final engine in the T4D lineup. Above 600 kW, Gillette's options are the SPVD/SPMI Tier II/III standby models (for emergency duty only).
Why do the standby and prime ratings differ on the T4D-6000?
The T4D-6000 is the only T4D model where standby (600 kW / 932 bhp) and prime (570 kW / 850 bhp) ratings differ. All other T4D models have identical standby/prime ratings. At 600 kW, the engine operates closer to its thermal ceiling, requiring a 5% derating for unlimited continuous hours.
How does the T4D-6000 compare to the Tier III SPVD-6000?
Both are 600 kW on Volvo 16.1L I6 engines. The T4D-6000 (TWD1683GE, Tier 4 Final) has SCR aftertreatment and DEF requirement but better fuel efficiency. The SPVD-6000 (TWD1644GE, Tier II) is simpler with no aftertreatment. Choose based on emissions compliance requirements.
DEF consumption at 600 kW?
Approximately 6.2% of diesel. At 37.2 gal/hr diesel, expect ~2.3 gal/hr DEF at full load.

Compatible equipment

Similar models

Gillette

New

Gillette T4D-3500

350 kW standby · Diesel · Liquid-cooled

350 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1385VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.

Tier 4 Final3-phasecommercialhospital

Gillette

New

Gillette SPVD-6000

600 kW standby · Diesel · Liquid-cooled

600 kW stationary diesel standby generator with Volvo Penta TWD1644GE 16.1L engine. Water-to-air aftercooling. Stamford HCI634G alternator, Basler DGC-2020.

Tier 23-phasedata-centerhospital

Blue Star Power Systems

New

Blue Star VD600-04FT4

600 kW standby · Diesel · Liquid-cooled

600 kW standby / 570 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1683GE 16.12L inline-six with SCR/DPF/DOC, DSE DCP7310 controller, three-phase 208-600V.

Tier 4 Final3-phaselarge-commercialhospital-non-critical

Gillette

New

Gillette SPVD-5500

550 kW standby · Diesel · Liquid-cooled

550 kW stationary diesel standby generator with Volvo Penta TAD1642GE 16.1L engine. Stamford HCI534F alternator, Basler DGC-2020 controller. Made in USA.

Tier 23-phasedata-centerhospital

Gillette

New

Gillette SPVD-5000

500 kW standby · Diesel · Liquid-cooled

500 kW stationary diesel standby generator with Volvo Penta TAD1641GE 16.1L engine. Stamford HCI534 alternator, Basler DGC-2020 controller. Made in USA.

Tier 23-phasedata-centerhospital

Gillette

New

Gillette SPVD-7000

700 kW standby · Diesel · Liquid-cooled

700 kW stationary diesel standby generator with Volvo Penta TWD1744GE 17.26L engine. Stamford S6DC311 alternator, Basler DGC-2020 controller. Gillette's largest Volvo unit.

Tier 23-phasedata-centerhospital

Need service or parts for the Gillette T4D-6000?

We service every major OEM and stock genuine parts for the most common models.