300 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1383VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.
The Gillette T4D-3000 is a 300-kilowatt Tier 4 Final / Stage V diesel generator on Volvo's TAD1383VE — a 12.8L inline-6 with water-to-air aftercooling and SCR aftertreatment. This is the T4D lineup's transition to H2O-to-air cooling (the T4D-2500 uses air-to-air). Rated at 300 kW for both standby and prime. Basler DGC-2020 controller.
The T4D-3000 combines two heat sources: the turbocharged 12.8L at 469 bhp AND the SCR catalyst system's exothermic reaction. Water-to-air aftercooling provides better charge cooling consistency under this combined thermal load. The Tier III SPVD-3000 (same 12.8L at 300 kW) uses air-to-air because it doesn't have the SCR heat contribution.
At 300 kW Tier 4 Final, the T4D-3000 requires both standard diesel service and DEF/SCR maintenance. The water-to-air aftercooler adds an additional coolant circuit to monitor. We treat every T4D service visit as three systems: engine, cooling, and aftertreatment.
Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.
Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.
Estimate runtime on this tank
Estimated runtime
11.8 hours(0.5 days)
Fuel consumption ≈ 16.97 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.
Service intervals
Manufacturer-recommended intervals for the Gillette T4D-3000 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.
Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
≈ 20,000 hours
Load bank test
Every 12 months
Common failure modes
What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.
Component
Symptom
Typical hours
Severity
DEF system (SCR catalyst)
Derate warning, NOx fault, DEF quality alert
4,380+
moderate
Fuel quality
Injector fouling, hard starting
4,380+
moderate
Battery
Failed to start, slow crank
8,760+
minor
Frequently Asked Questions
Why does the T4D-3000 switch to water-to-air aftercooling?
At 300 kW from 12.8L (469 bhp, same as the Tier III SPVD-3000's TAD1351GE), the T4D-3000 uses H2O-to-air aftercooling for more effective charge cooling at high output with the additional heat from SCR aftertreatment. The T4D-2500 uses air-to-air; the T4D-3000 and T4D-3500 switch to water-to-air.
DEF consumption at 300 kW?
Approximately 6.3% of diesel. At 22.0 gal/hr diesel at full load, expect ~1.4 gal/hr DEF.
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
250 kW standby · Diesel · Liquid-cooled
250 kW Tier 4 Final diesel for hospitals, municipal sites, and prime power in air-quality-restricted CARB jurisdictions.
250 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1381VE 12.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette T4D-3500
Factory-direct Tier 4 Final at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — EPA/CARB compliant, no lock-in.
350 kW standby · Diesel · Liquid-cooled
350 kW Tier 4 Final diesel for hospitals, data centers, municipal sites, and prime power in CARB jurisdictions.
350 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1385VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette SPVD-3000
Factory-direct at 15-30% below major brands. Volvo Penta 12.8L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
300 kW standby · Diesel · Liquid-cooled
300 kW diesel standby for hospitals, hotels, data centers, and large commercial or industrial facilities.
300 kW stationary diesel standby generator with Volvo Penta TAD1351GE 12.8L engine. Stamford S4L1D alternator, Basler DGC-2020 controller. Made in USA.
Tier 33-phasecommercialhospital