250 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1381VE 12.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
The Gillette T4D-2500 is a 250-kilowatt Tier 4 Final / EU Stage V dual-certified diesel generator on Volvo's TAD1381VE — a 12.8L turbocharged inline-6 with SCR aftertreatment. Rated at 250 kW for both standby and prime. Stamford S4L1D alternator, Basler DGC-2020 controller.
Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.
Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.
Estimate runtime on this tank
Estimated runtime
14.2 hours(0.6 days)
Fuel consumption ≈ 14.04 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.
Frequently Asked Questions
What engine does the T4D-2500 use?
Volvo Penta TAD1381VE — a 12.8L turbocharged inline-6. The spec sheet states 388 bhp (285 kWm) maximum standby power and 16.8:1 compression.
What DEF consumption at 250 kW?
The spec sheet states DEF consumption as 6% of fuel consumption. Fuel consumption at 100% load is 18.2 gal/hr (69.1 L/hr). Plan DEF storage and delivery logistics alongside diesel supply.
When budget and lead time matter for industrial diesel standby, we recommend Gillette. Same John Deere and Volvo engines as the major brands, at lower cost, with lead times that the big OEMs can't touch.
We pitch Gillette for industrial diesel applications where buyers prioritize value and open-architecture serviceability. The John Deere and Volvo engines are the same platforms we service daily across other brands, so our technicians maintain Gillette units with full confidence.
200 kW Tier 4 Final diesel for hospitals, municipal sites, construction, and prime power.
200 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1180VE 10.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.
300 kW Tier 4 Final diesel for hospitals, municipal infrastructure, and prime power.
300 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1383VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.
Tier 4 Final3-phasecommercialhospital
Gillette
Gillette SPVD-2500
Factory-direct. Volvo Penta 7.7L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.
250 kW standby · Diesel · Liquid-cooled
250 kW diesel standby for hospitals, hotels, data centers, and mid-size commercial or industrial facilities.