Gillette · T4D Series (Tier 4 Final Prime Diesel)

Gillette T4D-2500

250 kW standby · Diesel · Liquid-cooled

250 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1381VE 12.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.

Gillette Gillette T4D-2500 generator — specifications and details
Standby power
250 kW / 250 kW prime
Voltage options
120/208V, 120/240V, 277/480V, 346/600V, 127/220V
Frequency / Phase
60 Hz · 3-phase
Engine
Volvo Penta TAD1381VE · 12.8L
EPA / Emissions
Tier 4 Final
Alternator
Stamford S4L1D-D311

Overview#

The Gillette T4D-2500 is a 250-kilowatt Tier 4 Final / EU Stage V dual-certified diesel generator on Volvo's TAD1381VE — a 12.8L turbocharged inline-6 with SCR aftertreatment. Rated at 250 kW for both standby and prime. Stamford S4L1D alternator, Basler DGC-2020 controller.

Our service experience#

We service Tier 4 Final Volvo diesel generators, including the SCR and DEF systems: fluid quality, catalyst condition and diagnostics.

Engineering specifications

Physical

Length
200 in
Width
72 in
Height
82 in
Wet weight
6,077 lb

Acoustic

Sound @ 7m, full load
83 dBA
Enclosure
Sound-attenuated

Fuel system & runtime

Fuel use @ full load
18.2 GPH

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Gillette T4D-2500

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Gillette T4D-2500

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

14.2 hours(0.6 days)

Fuel consumption ≈ 14.04 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Frequently Asked Questions

What engine does the T4D-2500 use?
Volvo Penta TAD1381VE — a 12.8L turbocharged inline-6. The spec sheet states 388 bhp (285 kWm) maximum standby power and 16.8:1 compression.
What DEF consumption at 250 kW?
The spec sheet states DEF consumption as 6% of fuel consumption. Fuel consumption at 100% load is 18.2 gal/hr (69.1 L/hr). Plan DEF storage and delivery logistics alongside diesel supply.

Compatible equipment

More in the T4D Series (Tier 4 Final Prime Diesel)

100–600 kW Tier 4 Final diesel — Volvo Penta engines with SCR.

Why we recommend Gillette

When budget and lead time matter for industrial diesel standby, we recommend Gillette. Same John Deere and Volvo engines as the major brands, at lower cost, with lead times that the big OEMs can't touch.

We pitch Gillette for industrial diesel applications where buyers prioritize value and open-architecture serviceability. The John Deere and Volvo engines are the same platforms we service daily across other brands, so our technicians maintain Gillette units with full confidence.

See all Gillette generators →

Similar models

Gillette Gillette T4D-2000 200 kW liquid-cooled standby generator

Gillette

Gillette T4D-2000

Factory-direct Tier 4 Final. Volvo Penta 10.8L engine + Basler controller — EPA emissions certified, no lock-in.

200 kW standby · Diesel · Liquid-cooled

200 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1180VE 10.8L engine. SCR aftertreatment, DEF, Basler DGC-2020 controller. Made in USA.

Tier 4 Final3-phasecommercialhospital
Gillette Gillette T4D-3000 300 kW liquid-cooled standby generator

Gillette

Gillette T4D-3000

Factory-direct Tier 4 Final. Volvo Penta 12.8L engine + Basler controller — EPA emissions certified, no lock-in.

300 kW standby · Diesel · Liquid-cooled

300 kW Tier 4 Final / Stage 5 diesel generator with Volvo Penta TAD1383VE 12.8L engine. Water-to-air aftercooled, SCR+DEF, Basler DGC-2020. Made in USA.

Tier 4 Final3-phasecommercialhospital
Gillette Gillette SPVD-2500 250 kW liquid-cooled standby generator

Gillette

Gillette SPVD-2500

Factory-direct. Volvo Penta 7.7L engine + Basler controller — no proprietary lock-in. 3-7 day lead times.

250 kW standby · Diesel · Liquid-cooled

250 kW stationary diesel standby generator with Volvo Penta TAD852GE 7.7L engine. Stamford S4L1D alternator, Basler DGC-2020 controller. USA factory built.

Tier 33-phasecommercialhospital

Services for the Gillette T4D-2500

Need service or parts for the Gillette T4D-2500?

We service every major OEM and stock genuine parts for the most common models.

Last reviewed: