Hipower Systems · HDI Series

Hipower HDI-2000

2000 kW standby · Diesel · Liquid-cooled

2000 kW standby diesel generator with Mitsubishi 16-cylinder engine. Flagship heavy-duty industrial unit.

Hipower Systems Hipower HDI-2000 generator — specifications and details
Standby power
2000 kW
Voltage options
277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Mitsubishi Heavy Industries S16R-Y2PTAW2-1
EPA / Emissions
Tier 2
Alternator
Stamford S7L1D

Overview#

The Hipower HDI-2000 is the flagship of the HDI diesel series — a 2000 kW (2 MW) standby generator powered by a Mitsubishi 16-cylinder turbocharged intercooled engine. The largest unit Hipower offers, competing directly with Cat C175 and Cummins QSK95 at significantly lower cost. NFPA 110 Level 1 rated. Manufactured in Olathe, Kansas.

Engineering specifications

Acoustic

Sound @ 7m, full load
81 dBA
Enclosure
Sound-attenuated

Fuel system & runtime

Fuel use @ full load
155 GPH

Request a quote

Get pricing & lead time on the Hipower HDI-2000

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Hipower HDI-2000

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

1.7 hours(0.1 days)

Fuel consumption ≈ 119.57 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Hipower HDI-2000 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours
Air filter
Every 500 hours
Fuel filter
Every 500 hours
Major overhaul
2,000 hours

Frequently Asked Questions

What is the standby rating of the Hipower HDI-2000?
The HDI-2000 is rated at 2000 kW (2 MW) standby at 277/480V, three-phase, 60 Hz. The flagship of the HDI series, it is NFPA 110 Level 1 certified and targets the largest data centers, utility, and industrial facilities requiring maximum-capacity emergency power from a single generator.
What engine powers the Hipower HDI-2000?
The HDI-2000 is powered by a Mitsubishi Heavy Industries S16R-Y2PTAW2-1 16-cylinder turbocharged-aftercooled diesel engine with a Stamford S7L1D alternator. The S16R-Y2PTAW2-1 is the highest-output variant of Mitsubishi's S16R large-frame industrial platform, delivering 2 MW standby capacity.
What are the service intervals for the HDI-2000?
Oil changes, air filter replacements, and fuel filter replacements are scheduled every 500 hours. Major overhaul is at 2,000 hours, per Mitsubishi Heavy Industries S16R series published maintenance requirements.
How does the HDI-2000 compare to Cat, Cummins, or Kohler at 2000 kW?
The HDI-2000 competes directly with Cat C175-16 and Cummins QSK95 at the 2 MW class, delivering equivalent NFPA 110 L1, seismic, and 200 mph wind certifications at 15-25% lower list price. The Mitsubishi S16R is a globally respected large-frame engine with established parts and service infrastructure for utility-scale applications.
Is the HDI-2000 NFPA 110 Level 1 compliant?
Yes. The HDI-2000 is NFPA 110 Level 1 certified with redundant starting, seismic certification, and 200 mph wind rating — the complete compliance package required for the most demanding Tier 3+ and Tier 4 data center, utility, and critical infrastructure standby applications.
Who services Hipower HDI generators in Northern California?
OnPoint Generators is an authorized Hipower dealer and service provider covering the Bay Area and Northern California. We provide HDI-2000 sales, startup commissioning, load bank testing, and comprehensive preventive maintenance contracts for 2 MW installations.

More in the HDI Series

60 to 2,000 kW industrial diesel standby across FPT, Volvo, and Mitsubishi platforms — data-center spec at 15–25% below Big 4 pricing.

Similar models

Hipower Systems Hipower HMW-2230 2.2 MW liquid-cooled standby generator

Hipower Systems

Hipower HMW-2230

The largest HMW model — MTU 16V4000 at 2.2 MW. 68L 16-cylinder V, 30,000-hour TBO. The maximum single-unit diesel generator for hyperscale data centers.

2.2 MW standby · Diesel · Liquid-cooled

2230 kW MTU 4000-series diesel generator. 2.2 MW single unit. NFPA 110 Level 1, seismic certified. US manufactured in Olathe, Kansas.

Tier 23-phaseindustrial-standbydata-center
Blue Star Power Systems Blue Star MD2000-01 2 MW liquid-cooled standby generator

Blue Star Power Systems

Blue Star MD2000-01

Open Basler controller + Mitsubishi V16 engine + Stamford alternator — no proprietary lock-in. 2 MW class without OEM dealer dependency.

2 MW standby · Diesel · Liquid-cooled

2000 kW Tier 2 diesel standby generator built by Blue Star Power Systems. Mitsubishi S16R-Y2PTAW2-1 65.4L V16 engine, Stamford S7L1D alternator, DSE DCP7310 controller. Three-phase, 208–4160V.

Tier 23-phaseindustrialmunicipal
Caterpillar Cat 3516B 2 MW liquid-cooled standby generator

Caterpillar

Cat 3516B

2000 kW diesel with CAT 3516B V-16. Best resale value in class. Paralleling for multi-MW. ~200 US dealers.

2 MW standby · Diesel · Liquid-cooled

1640-2250 kW diesel generator with Cat 3516B V-16 engine. 69L displacement, EUI fuel system, EMCP 4.2B controller.

3-phasedata-centermission-critical

Need service or parts for the Hipower HDI-2000?

We service every major OEM and stock genuine parts for the most common models.