Generac · MD Series (Modular Diesel)

Generac MD500-T4

500 kW standby / 456 kW prime · Diesel · Liquid-cooled

500 kW modular diesel standby generator system, Tier 4 Final emissions. Factory-paralleled configuration with Perkins 18.1L inline-6 engine for N+1 redundancy.

Generac Generac MD500-T4 generator — specifications and details
Standby power
500 kW / 456 kW prime
Voltage options
120/208V, 120/240V, 277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Perkins 2806F-E18TAG1 · 18.1L
EPA / Emissions
Tier 4 Final
Alternator
Generac K0552124N27

Overview#

The Generac MD500-T4 is a 500 kW modular diesel standby generator system meeting EPA Tier 4 Final emissions standards. It uses a Perkins 18.1-liter turbocharged and aftercooled inline-six engine -- larger displacement than the standard MD500's 15.2L Perkins -- paired with diesel exhaust aftertreatment technology including a diesel particulate filter (DPF) and selective catalytic reduction (SCR) system. The DSE G8601 controller manages both generator operation and aftertreatment system functions.

As part of Generac's Modular Power System (MPS) platform, the MD500-T4 is factory-configured with integrated paralleling controls for plug-and-play scalability. The Tier 4 Final compliance makes this model suitable for installations in air quality management districts with strict emissions limits, or for facilities that prioritize environmental responsibility. The modular architecture provides N+1 redundancy with independent serviceability of each module. Generac's sheet lists the open set only with its 703-gallon sub-base fuel tank, at 188.5 x 71.0 x 116.8 inches (the height includes the tank).

Our Service Experience#

The MD500-T4's Tier 4 Final aftertreatment system adds maintenance requirements beyond a standard diesel genset. The DPF requires periodic regeneration, and DEF quality and level must be monitored. Low-runtime standby installations are particularly susceptible to incomplete regeneration cycles, so we recommend exercise runs long enough to complete a full DPF regeneration. The 18.1L Perkins platform is well-proven in this power class, and the paralleling controls follow the same architecture as the rest of the MD Series.

Engineering specifications

Fuel system & runtime

Fuel use @ full load
36.5 GPH
Fuel use @ 75% load
27.8 GPH
Fuel use @ 50% load
19.7 GPH

Thermal & ventilation

Heat to coolant
966,495 BTU/hr
Exhaust flow
935 CFM
Exhaust temp
911 °F
Combustion air
1,338 CFM
Ventilation air
25,603 CFM

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Generac MD500-T4

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Generac MD500-T4

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

7.1 hours(0.3 days)

Fuel consumption ≈ 28.16 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Frequently Asked Questions

What is the difference between the MD500-T4 and the MD500?
The MD500-T4 meets EPA Tier 4 Final emissions standards, using a larger Perkins 18.1L engine (versus the 15.2L in the standard MD500) paired with diesel exhaust aftertreatment including a diesel particulate filter (DPF) and selective catalytic reduction (SCR) using diesel exhaust fluid (DEF). The Tier 4 Final variant is required in jurisdictions with strict emissions regulations or for facilities seeking to minimize environmental impact. Both models produce 500 kW standby output with factory-integrated paralleling.
What is the fuel consumption of the MD500-T4?
The MD500-T4 uses the Perkins 2806F-E18TAG1 18.1L engine. At standby rating, fuel consumption is approximately 36.5 gallons per hour at full load, 27.8 gph at 75% load, 19.7 gph at 50% load, and 12.3 gph at 25% load per module. DEF consumption is approximately 1.3 gph at full load.
What voltages are available?
The MD500-T4 is available in three-phase configurations at 120/208V, 120/240V, and 277/480V, all at 60 Hz.

Compatible equipment

Similar models

Generac Generac SD500 500 kW liquid-cooled standby generator

Generac

Generac SD500

500 kW industrial diesel with Perkins engine. Paralleling for multi-MW installations.

500 kW standby · Diesel · Liquid-cooled

500 kW diesel standby generator. Perkins 15.2L turbocharged-aftercooled inline-6, EPA Certified Stationary Emergency.

3-phasecommercial-standbyindustrial
Generac Generac MD500 500 kW liquid-cooled standby generator

Generac

Generac MD500

500 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture.

500 kW standby · Diesel · Liquid-cooled

500 kW modular diesel standby generator system. Factory-paralleled configuration with Perkins 15.2L inline-6 engine for N+1 redundancy.

3-phasecommercial-standbyindustrial
Generac Generac MD600 600 kW liquid-cooled standby generator

Generac

Generac MD600

600 kW modular diesel with factory paralleling. N+1 redundancy, easier installation, and scalable power architecture.

600 kW standby · Diesel · Liquid-cooled

600 kW modular diesel standby generator system. Factory-paralleled configuration with Perkins 18.1L inline-6 engine for N+1 redundancy.

3-phasecommercial-standbyindustrial

Services for the Generac MD500-T4

Need service or parts for the Generac MD500-T4?

We service every major OEM and stock genuine parts for the most common models.