Blue Star Power Systems · Volvo Penta Diesel Mobile

Blue Star VD550-04FT4MP

550 kW standby / 500 kW prime · Diesel · Liquid-cooled

550 kW standby / 500 kW prime Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TWD1682GE six-cylinder engine, 572RSL6429 alternator, DCP7310 controller, 550-gallon integrated fuel tank.

Blue Star Power Systems Blue Star VD550-04FT4MP generator — specifications and details
Standby power
550 kW / 500 kW prime
Voltage options
120/208V, 277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Volvo Penta TWD1682GE · 16.12L
EPA / Emissions
Tier 4 Final
Alternator
572RSL6429

Overview#

The Blue Star VD550-04FT4MP is a 550-kilowatt standby / 500-kilowatt prime EPA Tier 4 Final / EU Stage 5 mobile trailer diesel generator powered by the Volvo Penta TWD1682GE — a 16.12-liter, six-cylinder turbocharged and charge-air-cooled engine.

Blue Star Power Systems mounts the TWD1682GE on a trailer with an integrated 550 Gallon fuel tank and 52.8-gallon DEF tank, paired with a 572RSL6429 alternator and DCP7310 controller. Approximate Ship Weight is 24,750 lbs. The trailer is 334.50 × 99.50 × 144 in.

Standby vs Prime at 550 kW#

The VD550-04FT4MP is rated 550 kWe standby and 500 kWe prime. This is an important distinction for applications where continuous prime power use is anticipated — size the system to the prime rating (500 kWe) for continuous duty applications. Do not use the 550 kWe standby rating to size a continuous prime power application.

The 334.5 × 99.5 Inch Platform#

The trailer footprint is 334.50 × 99.50 in with an integrated 550 Gallon fuel tank. The DEF tank capacity is 52.8 gal. Plan DEF logistics the same way fuel logistics are planned.

When to specify the VD550-04FT4MP#

  • 500–550 kW three-phase emergency standby mobile power at industrial, municipal, healthcare, or data center sites
  • Prime power applications at 500 kWe or below (use the prime rating, not standby, for continuous duty sizing)
  • Sites up to 4,921 ft elevation at ambient temperatures to 122°F
  • Applications requiring EU Stage 5 dual certification
  • Projects where the 334.5 × 99.5 in trailer is acceptable and 550 kWe standby / 500 kWe prime satisfies the load

Our service experience#

The 52.8-gallon DEF tank at 38.3 gph diesel consumption means DEF must be treated as a primary consumable on extended deployments. At an approximate shipping weight of 24,750 lbs and 334.5 in length, site access logistics require advance planning — confirm road weight limits and site entry dimensions before deployment. Full-load testing (38.3 gph) is mandatory for maintaining aftertreatment health. The 144 in total unit height may require oversize permits in some jurisdictions.

Engineering specifications

Physical

Length
334.5 in
Width
99.5 in
Height
144 in

Acoustic

Sound @ 7m, full load
75 dBA
Enclosure
Sound-attenuated

Fuel system & runtime

Integral fuel tank
550 gal
Fuel use @ full load
38.3 GPH
Fuel use @ 75% load
29.1 GPH
Fuel use @ 50% load
20.6 GPH
DEF tank
52.8 gal

Thermal & ventilation

Heat to coolant
713,160 BTU/hr
Heat radiated
688,500 BTU/hr
Exhaust flow
4,347 CFM
Exhaust temp
826 °F
Combustion air
1,667 CFM
Ventilation air
27,122 CFM

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Blue Star VD550-04FT4MP

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Blue Star VD550-04FT4MP

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

18.6 hours(0.8 days)

Fuel consumption ≈ 29.55 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Before you buy this generator

Can a second qualified provider program a replacement controller for the Blue Star VD550-04FT4MP, using access issued to us?

Ask every supplier to answer in writing. Service access is part of what you are buying.

Open the 13-question checklist

Frequently Asked Questions

What engine does the VD550-04FT4MP use?
The Volvo Penta TWD1682GE — a 16.12-liter, six-cylinder turbocharged and charge-air-cooled diesel. The unit is rated 550 kWe standby and 500 kWe prime. EPA Tier 4 Final and EU Stage 5 dual certification applies. The DEF tank capacity is 52.8 gal. Rated power is available to 4,921 ft (1,500 m) at 122°F (50°C).
What controller does the VD550-04FT4MP use?
The DCP7310 Digital Control Panel, with CAN Bus J1939 engine communication, digital metering, RS-485 interface, 8 programmable contact inputs, 10 contact outputs, and NFPA 110 Level 1 compatibility. The panel is cULus Listed and CE Approved with IP 65 ingress protection (with supplied gasket). A 24V battery system and battery charger are included.
What is the difference between the VD550-04FT4MP 550 kWe standby and 500 kWe prime ratings?
The VD550-04FT4MP carries separate standby and prime ratings: 550 kWe standby (emergency use, no continuous power duty limit) and 500 kWe prime (continuous variable power, unlimited hours). Specify the appropriate rating for the application.
What are the fuel and DEF logistics for the VD550-04FT4MP?
Combustion air draw is 1,667 CFM; ventilation air requirement is 27,122 CFM; heat rejected to coolant at standby is 11,886 BTU/min; radiated heat to ambient at standby is 11,475 BTU/min.

Compatible equipment

More in the Volvo Penta Diesel Mobile

100–600 kW Tier 4 Final mobile trailer diesel generators on Volvo Penta platforms — all eight models EPA/EU Stage 5 certified.

Similar models

Blue Star Power Systems Blue Star VD550-04FT4 550 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star VD550-04FT4

550 kW standby · Diesel · Liquid-cooled

550 kW standby / 500 kW prime Tier 4 Final diesel generator from Blue Star Power Systems. Volvo Penta TWD1682GE 16.12L inline-six, DCP7310 controller, three-phase 208-600V.

Tier 4 Final3-phaselarge-commercialhospital-non-critical
Blue Star Power Systems Blue Star VD600-04FT4MP 600 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star VD600-04FT4MP

600 kW standby · Diesel · Liquid-cooled

600 kW standby / 570 kW prime Tier 4 Final / EU Stage 5 mobile trailer diesel generator built by Blue Star Power Systems. Volvo Penta TWD1683GE six-cylinder engine, 572RSL6431 alternator, DCP7310 controller, 550-gallon integrated fuel tank.

Tier 4 Final3-phaseconstructiontemporary-power
Blue Star Power Systems Blue Star VD550-01 550 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star VD550-01

550 kW standby · Diesel · Liquid-cooled

550 kW Tier 2 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1642GE-B 16.1L inline-six with DCP7310 controller, 208-600V output.

Tier 23-phasecommerciallarge-commercial

Services for the Blue Star VD550-04FT4MP

Need service or parts for the Blue Star VD550-04FT4MP?

We service every major OEM and stock genuine parts for the most common models.

Last reviewed: