Triton Power · TP-RS

Triton Power TP-RS500-T4F Rental Grade

440 kW standby / 400 kW prime · Diesel · Liquid-cooled

440 kW Tier 4 Final rental grade diesel generator with Scania DC13 084A engine. Reinforced enclosure and heavy-duty chassis for rental fleet and jobsite use.

Triton Power Triton Power TP-RS500-T4F Rental Grade generator — specifications and details
Standby power
440 kW / 400 kW prime
Voltage options
120/208V, 277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Scania DC13 084A · 12.7L
EPA / Emissions
Tier 4 Final
Alternator
Leroy Somer LSA47.2
rentalmobileCommercialevents
Configure & Quote

Overview#

The Triton Power TP-RS500-T4F is a 440 kW rental grade diesel generator built for high-demand fleet and jobsite power applications. Powered by the Scania DC13 084A six-cylinder turbocharged diesel engine (12.7 L displacement) paired with a Leroy Somer alternator, it delivers 440 kW / 550 kVA standby and 400 kW / 500 kVA prime power at 1800 RPM. The unit meets EPA Tier 4 Final emissions standards through Scania's integrated DOC/DPF/SCR aftertreatment system.

Built for rental fleet durability, the TP-RS500-T4F features a reinforced sound-attenuated enclosure, heavy-duty steel chassis with forklift pockets and crane lifting points, and 125% integrated fluid containment. Available in three-phase configurations (120/208V and 277/480V), it delivers primary power for large commercial construction, data center temporary backup, industrial plant shutdowns, and major event installations where half-megawatt Tier 4 Final compliant generation is required.

Our service experience#

The Scania DC13 at its higher-output tuning delivers impressive power density from the same 12.7-liter inline-6 platform used in the 400 kVA model, making the TP-RS500-T4F the go-to rental unit when projects need just under 500 kVA of prime power. In fleet rotation, these units handle the heaviest single-genset loads — large commercial construction main feeds, temporary data center backup, and industrial shutdown support. The Tier 4 Final aftertreatment system requires DEF and periodic DPF service, but automatic regeneration operates transparently under normal loaded conditions. At this power level, fuel logistics become a meaningful operational consideration for rental customers, and we advise planning for daily fuel deliveries on sustained full-load applications. The rental grade enclosure and heavy-duty chassis are built to withstand the transport and handling demands of large-equipment rental operations.

Engineering specifications

Physical

Length
167.8 in
Width
62.8 in
Height
98 in
Dry weight
12,103 lb

Acoustic

Sound @ 7m, full load
70 dBA

Fuel system & runtime

Integral fuel tank
269 gal
Fuel use @ full load
23.91 GPH
Fuel use @ 75% load
18.1 GPH
Fuel use @ 50% load
12.23 GPH

Ready to order this model?

Configure your Triton Power TP-RS500-T4F Rental Grade

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Triton Power TP-RS500-T4F Rental Grade

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

14.6 hours(0.6 days)

Fuel consumption ≈ 18.44 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Frequently Asked Questions

How long can the TP-RS500-T4F run continuously on a rental jobsite?
The TP-RS500-T4F is rated for continuous prime power operation at 400 kW. With regular refueling and DEF replenishment, it supports 24/7 operation on large construction sites and industrial projects. Follow Scania's recommended service intervals during extended runtime.
What is the estimated fuel consumption for the TP-RS500-T4F?
At prime-rated load (400 kW), the Scania DC13 084A engine typically consumes approximately 26 GPH of diesel. Actual consumption varies with load profile, ambient conditions, and altitude. DEF consumption is typically 2-3% of diesel usage.
Can the TP-RS500-T4F be paralleled with other units for more power?
Yes. The TP-RS500-T4F includes provisions for paralleling with compatible generators to scale capacity for large projects. The digital controller supports load sharing and synchronization. Consult the factory or your rental provider for specific paralleling configurations and switchgear requirements.

Why we recommend Triton Power

Triton Power is our value brand for mobile and portable diesel generators, and an emerging option for industrial standby. When MQ Power's pricing is a stretch or lead times are too long, Triton delivers comparable capability at a lower price point with faster availability.

We are developing our Triton Power sales relationship and building fleet experience. Every engine platform Triton uses — Perkins, John Deere, Kubota, Scania, Volvo — is one we already service daily across other brands. Triton's open architecture means our technicians can maintain these units with standard tooling and widely available parts.

See all Triton Powergenerators →

Similar models

Triton Power

Triton Power TP-RS400-T4F Rental Grade

350 kW standby · Diesel · Liquid-cooled

350 kW Tier 4 Final rental grade diesel generator with Scania DC13 084A engine. Reinforced enclosure and heavy-duty chassis for rental fleet and jobsite use.

Tier 4 Final3-phaserentalmobile

Triton Power

Triton Power TP-RS700-T4F Twin Pack Rental Grade

610 kW standby · Diesel · Liquid-cooled

610 kW Tier 4 Final rental grade twin-pack diesel generator with dual Scania DC13 084A engines. Reinforced enclosure and heavy-duty chassis for rental fleet and jobsite use.

Tier 4 Final3-phaserentalmobile
Triton Power Triton Power TP-V550-T4F 550 kW liquid-cooled standby generator

Triton Power

Triton Power TP-V550-T4F

550 kW standby · Diesel · Liquid-cooled

550 kW Tier 4 Final diesel generator with Volvo TWD1672GE engine. For commercial, industrial, and data center standby applications.

Tier 4 Final3-phasecommercial-standbyindustrial

Need service or parts for the Triton Power TP-RS500-T4F Rental Grade?

We service every major OEM and stock genuine parts for the most common models.

Last reviewed: