MQ Power · WhisperWatt Super-Silent

MQ Power DCA-36 WhisperWatt

40 kW standby / 36 kW prime · Diesel · Liquid-cooled

36 kW prime (40 kW standby) portable diesel generator. The largest single-phase WhisperWatt — Isuzu 4LE2X powered at 65 dBA with 79.2-gal tank.

Standby power
40 kW / 36 kW prime
Voltage options
120/240V
Frequency / Phase
60 Hz · 1-phase
Engine
Isuzu 4LE2X · 2.93L
EPA / Emissions
Tier 4 Final
residentialconstruction-largerental-fleettemporary-powercommercial-backup
Configure & Quote

Overview#

The MQ Power DCA-36 WhisperWatt is the flagship of the single-phase WhisperWatt lineup — 36 kW prime (40 kW standby) from an Isuzu 4LE2X 2.93L turbocharged engine, the same powerplant found in the three-phase DCA-45. At 65 dB(A) at 23 feet with a 79.2-gallon integral tank, it delivers the full WhisperWatt experience in a single-phase-only configuration.

The DCA-36 exists because not every 36 kW load needs three-phase power. Large homes, small commercial buildings, and construction sites with heavy single-phase tool loads benefit from the simplified alternator and wiring — no three-phase distribution panel required.

Same engine as the DCA-45#

The Isuzu 4LE2X is the proven mid-range engine in the WhisperWatt lineup. At 2.93L with turbocharging, it achieves Tier 4 Final compliance through EGR and DPF — no DEF required. The engine produces 65.7 bhp at 1800 RPM, the same in both the DCA-36 and DCA-45. The power difference is in the alternator configuration, not the engine.

Common applications#

  • Large residential backup including central HVAC
  • Small commercial building emergency power
  • Construction sites with heavy single-phase tool loads (welders, compressors)
  • Equipment rental for large residential and small commercial jobs

Engineering specifications

Acoustic

Sound @ 7m, full load
65 dBA
Enclosure
Sound-attenuated

Fuel system & runtime

Integral fuel tank
79.2 gal
Fuel use @ full load
2.93 GPH

Ready to order this model?

Configure your MQ Power DCA-36 WhisperWatt

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the MQ Power DCA-36 WhisperWatt

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

35.0 hours(1.5 days)

Fuel consumption ≈ 2.26 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Frequently Asked Questions

What's the difference between the DCA-36 and DCA-45?
Both use the same Isuzu 4LE2X engine and share a 79.2-gallon fuel tank, but the DCA-36 is single-phase only (120/240V) while the DCA-45 is switchable single/three-phase (including 208V, 480V). Choose the DCA-36 when your load is purely single-phase — it delivers the same 36 kW prime without the three-phase switching complexity.
Does the DCA-36 require DEF?
No. Like the DCA-45, the DCA-36 uses an Isuzu 4LE2X with EGR and DPF aftertreatment — no DEF required. Tier 4 Final compliance without urea.
What can 36 kW single-phase power?
36 kW single-phase at 120/240V handles a large residential load including central AC, or a small commercial building's essential circuits. It's the maximum single-phase output in the WhisperWatt lineup — above this, three-phase configurations are required.

Similar models

MQ Power

MQ Power DCA-20 WhisperWatt

WhisperWatt 20 kW single-phase — Isuzu diesel at 1800 RPM, 65 dBA at 7m, 120/240V output, 41.7-gal tank. Same 20 kW as the DCA-25 but for single-phase-only loads.

22 kW standby · Diesel · Liquid-cooled

20 kW prime (22 kW standby) portable diesel generator. Isuzu-powered WhisperWatt single-phase at 65 dBA — same power as the DCA-25, single-phase only.

Tier 4 FinalSingle-phaseresidentialconstruction-small
MQ Power MQ Power DCA-45 WhisperWatt 40 kW liquid-cooled standby generator

MQ Power

MQ Power DCA-45 WhisperWatt

WhisperWatt 45 kVA — 66 dBA at 7m, Isuzu 4LE2X 2.93L, no DEF required (DPF+EGR only), switchable phase output, 79-gal tank.

40 kW standby · Diesel · Liquid-cooled

45 kVA (36 kW prime) portable diesel generator. Compact WhisperWatt Super-Silent for construction sites, events, and commercial temporary power.

Tier 4 Final3-phaseconstruction-largerental-fleet

MQ Power

MQ Power DCA-40 WhisperWatt

WhisperWatt 36 kVA with Kubota V2403-CR-T — 63 dBA at 7m, quietest in the three-phase lineup. No DEF required (DOC+EGR only), 41.7-gal tank.

30.2 kW standby · Diesel · Liquid-cooled

36 kVA (28.8 kW prime) portable diesel generator. Kubota-powered WhisperWatt Super-Silent at 63 dBA — the quietest unit in the MQ Power three-phase lineup.

Tier 4 Final3-phaseconstruction-largerental-fleet

Need service or parts for the MQ Power DCA-36 WhisperWatt?

We service every major OEM and stock genuine parts for the most common models.