Hipower Systems · HRFW Mobile Series

Hipower HRFW-400

352 kW standby / 320 kW prime · Diesel · Liquid-cooled

400 kVA (352 kW standby) mobile diesel generator with FPT engine. Tier 4 Final. Largest trailer-mounted unit in the HRFW rental series.

Hipower Systems Hipower HRFW-400 generator — specifications and details
Standby power
352 kW / 320 kW prime
Voltage options
277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
FPT Industrial C13ENTZW69
EPA / Emissions
Tier 4 Final
Alternator
Stamford S4L1D.F41
Commercialrental-fleettemporary-power

Overview#

The Hipower HRFW-400 T4F is the largest unit in the HRFW FPT-powered mobile rental series — a 400 kVA (352 kW standby / 320 kW prime) trailer-mounted diesel generator designed for large construction projects, industrial shutdowns, and high-demand temporary power applications. The FPT Industrial diesel engine provides proven heavy-duty performance backed by an established service and parts network throughout Northern California.

Manufactured at Hipower's Olathe, Kansas facility, the HRFW-400 delivers 352 kW of standby power in a road-mobile package that can be positioned, connected, and producing power the same day it arrives on site. EPA Tier 4 Final certified for California deployment. Output is three-phase 277/480V at 60 Hz — matching standard US commercial and industrial electrical systems.

OnPoint Generators offers HRFW-400 units for rental and purchase, with full pre-deployment inspection and ongoing service support throughout the Bay Area and surrounding Northern California markets.

Engine Platform#

The HRFW-400 is powered by an FPT Industrial diesel engine from the Cursor series — a high-output, liquid-cooled inline configuration that delivers 352 kW of standby power while meeting EPA Tier 4 Final emissions. FPT (IVECO) engines are used in heavy construction equipment, agricultural machinery, and commercial trucks worldwide, which translates directly to parts availability and technician familiarity at authorized dealers throughout Northern California, including locations in the Bay Area, Sacramento, Fresno, and Stockton.

Running at 1,800 RPM, the engine pairs efficiently with the Stamford alternator to deliver stable 60 Hz output across variable load swings — a common requirement on active construction sites where compressors, lighting, and power tools cycle on and off continuously.

Built for Rental Deployment#

At 352 kW, the HRFW-400 is sized for the most demanding construction and industrial rental applications — large enough to feed a complete temporary distribution system for a major commercial project, while still trailer-mobile for repositioning between phases of a multi-site project. Key rental-ready features:

This size class is commonly deployed for: large commercial building renovations with full power offline, industrial plant shutdowns requiring maintained utility power, outdoor concerts and festival events with multiple stages, and utility contractor operations during substation or distribution line maintenance.

Service & Maintenance#

Rental-optimized service intervals account for the variable fueling, storage, and transport conditions of active fleet operation:

Pre-deployment inspection checklist (OnPoint standard before every dispatch):

  1. Verify engine oil level and condition
  2. Inspect and drain fuel filter water separator
  3. Load-test starting battery
  4. Grease and inspect trailer coupler and safety chains
  5. Confirm roadway lighting operational
  6. Test all enclosure door latches
  7. Check coolant level and inhibitor concentration
  8. Run at 25% load for 10 minutes, verify no alarms

Our Service Experience#

OnPoint Generators deploys HRFW-400 units for Bay Area construction contractors, semiconductor facility shutdowns, and large outdoor events requiring 300+ kW of portable power. The FPT engine platform's broad dealer coverage means parts are typically available same-day or next-day throughout Northern California, keeping rentals running without extended downtime. Our technicians service both the FPT engine and Stamford alternator end in-house, supporting fast turnaround between rental cycles.

Request a quote

Get pricing & lead time on the Hipower HRFW-400

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Hipower HRFW-400

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

10.5 hours(0.4 days)

Fuel consumption ≈ 19.01 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Hipower HRFW-400 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 250 hours or 6 months
Air filter
Every 500 hours
Fuel filter
Every 250 hours
Major overhaul
15,000 hours

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Trailer couplerWear from repeated hookup/release cycles — grease and inspect before each deployment500+minor
Fuel filterContamination from portable job site fueling — change at 250 hours250+minor
Starting batteryDeep discharge between deployments — battery maintainer required in storage4,380+minor

Frequently Asked Questions

What is the standby power output of the HRFW-400?
The HRFW-400 delivers 352 kW (400 kVA) standby and 320 kW prime. Output is three-phase 277/480V at 60 Hz — matching standard US commercial and industrial electrical systems.
What FPT engine does the HRFW-400 use, and what are the service advantages?
The HRFW-400 is powered by an FPT Industrial Cursor-series diesel — a high-output liquid-cooled inline engine that meets EPA Tier 4 Final. FPT (IVECO) engines are used in heavy construction equipment and commercial trucks worldwide, translating to established parts networks and technician familiarity at authorized dealers throughout Northern California, including Bay Area, Sacramento, Fresno, and Stockton locations.
Is the HRFW-400 California CARB compliant?
Yes. The HRFW-400 T4F carries EPA Tier 4 Final certification, satisfying California Air Resources Board requirements for unrestricted job site use without additional permits or variance applications.
How does the HRFW-400 compare to the HRFW-325 for large construction sites?
The HRFW-400 provides 352 kW standby versus the HRFW-325's 286 kW — 66 kW more capacity in the same trailer-mobile format. The additional headroom is valuable for large commercial building renovations, industrial plant shutdowns, and outdoor events with multiple high-draw loads operating simultaneously.
What does a pre-deployment inspection include for the HRFW-400?
OnPoint's standard pre-deployment checklist covers oil level, fuel filter water separator drain, battery load test, trailer coupler greasing and safety chain inspection, roadway lighting verification, enclosure latch inspection, coolant check, and a 25% load run for 10 minutes to confirm no alarms before dispatch.
What rental applications is the HRFW-400 best suited for in Northern California?
The HRFW-400 targets large commercial building renovations with full power offline, industrial plant shutdowns requiring maintained utility power, outdoor concerts and festival events with multiple stages, and utility contractor operations during substation or distribution line maintenance.

More in the HRFW Mobile Series

286 to 352 kW FPT-powered trailer generators — Tier 4 Final compliant for California job sites, built for rental and construction deployment.

Similar models

Hipower Systems Hipower HDI-350F 350 kW liquid-cooled standby generator

Hipower Systems

Hipower HDI-350F

Data center-grade features at 15-25% below Cat/Cummins/Kohler — full vertical integration with NFPA 110 L1, seismic, and 200 mph wind ratings.

350 kW standby · Diesel · Liquid-cooled

350 kW standby diesel generator with FPT engine. Heavy-duty industrial series.

Tier 33-phasecommercial-standbyindustrial
Hipower Systems Hipower HFW-350 350 kW liquid-cooled standby generator

Hipower Systems

Hipower HFW-350

350 kW flagship of the HFW series on FPT's C13TE3X 12.9L inline-6 — EPA Tier 3 certified, UL 2200 listed, US-built for the most demanding industrial and mission-critical standby applications.

350 kW standby · Diesel · Liquid-cooled

350 kW standby diesel generator with FPT C13TE3X 12.9L inline-6 engine and Stamford HCI 544 D alternator. EPA Tier 3. US manufactured in Olathe, Kansas. Top of the HFW series.

Tier 33-phasecommercial-standbyindustrial-standby
Hipower Systems Hipower HMW-370 350 kW liquid-cooled standby generator

Hipower Systems

Hipower HMW-370

MTU 1600-series 12-cylinder engine — more torque and transient response than 10-cylinder alternatives at the same power class.

350 kW standby · Diesel · Liquid-cooled

370 kW MTU-powered diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.

Tier 33-phaseindustrial-standbydata-center

Need service or parts for the Hipower HRFW-400?

We service every major OEM and stock genuine parts for the most common models.