Blue Star Power Systems · Volvo Penta Diesel Standby

Blue Star VD400-01

400 kW standby · Diesel · Liquid-cooled

400 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1353GE 12.8L inline-six with DCP7310 controller, 208-600V output.

Blue Star Power Systems Blue Star VD400-01 generator — specifications and details
Standby power
400 kW
Voltage options
120/208V, 277/480V, 347/600V
Frequency / Phase
60 Hz · 3-phase
Engine
Volvo Penta TAD1353GE · 12.8L
EPA / Emissions
Tier 3
Alternator
S4L1D-F41

Overview#

The Blue Star VD400-01 is a 400-kilowatt EPA Tier 3 diesel standby generator built around the Volvo Penta TAD1353GE.

The Volvo Penta TAD1353GE platform#

  • 12.8L displacement — bore 5.16 in, stroke 6.22 in, compression ratio 18.1:1
  • Output — 611 HP (449 kWm) at 1800 RPM
  • Altitude — rated power is available up to 3,280 ft (1,000 m) at ambient temperatures to 122°F (50°C)

When to spec the VD400-01#

  • Large commercial and industrial facilities: hospitals (non-critical), large hotels, manufacturing plants, data center edge deployments
  • Competitive bids against Kohler, Cummins, and Generac units

Our service experience#

The open-skid sound level is 91 dBA at full load; the Level 2 enclosure is 81 dBA and the Level 3 enclosure 73 dBA at full load, measured at 23 feet (7 meters). The 3,280 ft altitude deration is adequate for most Bay Area and Central Valley sites, but we verify elevation for foothill installations.#

Engineering specifications

Physical

Length
120 in
Width
66 in
Height
80 in
Dry weight
8,350 lb

Acoustic

Sound @ 7m, full load
91 dBA
Enclosure
Open

Fuel system & runtime

Fuel use @ full load
27.3 GPH
Fuel use @ 75% load
21.8 GPH
Fuel use @ 50% load
15.6 GPH

Thermal & ventilation

Heat to coolant
607,380 BTU/hr
Heat radiated
484,560 BTU/hr
Exhaust flow
2,790 CFM
Exhaust temp
923 °F
Combustion air
1,102 CFM

Documents & downloads

Spec sheets & manuals

Ready to order this model?

Configure your Blue Star VD400-01

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Blue Star VD400-01

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

9.5 hours(0.4 days)

Fuel consumption ≈ 21.06 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Before you buy this generator

Can a second qualified provider program a replacement controller for the Blue Star VD400-01, using access issued to us?

Ask every supplier to answer in writing. Service access is part of what you are buying.

Open the 13-question checklist

Frequently Asked Questions

What engine is in the VD400-01?
The Volvo Penta TAD1353GE — a 12.8-liter inline-six turbocharged-aftercooled diesel rated 611 HP (449 kWm) at 1800 RPM.
What controller does the VD400-01 use?
The DCP7310. It features CAN bus J1939 communications, RS-485 interface, IP 65 front panel rating, and remote communications via DSE2548 annunciator. cULus Listed and NFPA 110 Level 1 compatible.

Compatible equipment

More in the Volvo Penta Diesel Standby

100–700 kW Volvo Penta diesel standby across Tier 4 Final, Tier 3, and Tier 2 — 22 models, one and three-phase.

Similar models

Blue Star Power Systems Blue Star VD350-01 350 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star VD350-01

350 kW standby · Diesel · Liquid-cooled

350 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1352GE 12.8L inline-six with DCP7310 controller, 208-600V output.

Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems Blue Star VD450-01 450 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star VD450-01

450 kW standby · Diesel · Liquid-cooled

450 kW Tier 3 diesel standby generator from Blue Star Power Systems. Volvo Penta TAD1650GE 16.1L inline-six with DCP7310 controller, 208-600V output.

Tier 33-phasecommerciallarge-commercial
Blue Star Power Systems Blue Star PD400-01 400 kW liquid-cooled standby generator

Blue Star Power Systems

Blue Star PD400-01

400 kW standby · Diesel · Liquid-cooled

400 kW Tier 3 diesel standby generator built by Blue Star Power Systems. Perkins 2206D-E13TAG3 six-cylinder engine with charge air cooling, S4L1D-F41 alternator, DSE DCP7310 controller.

Tier 33-phasecommerciallight-industrial

Services for the Blue Star VD400-01

Need service or parts for the Blue Star VD400-01?

We service every major OEM and stock genuine parts for the most common models.

Last reviewed: