The Blue Star NG150-01 is a 150-kilowatt natural gas / LP standby generator built on the PSI 8.1LT inline-six platform. It is rated 150 kWe standby / 125 kWe prime on natural gas (115 kWe standby on LP). The NG150-01 is the entry point of Blue Star's NG-prefix gaseous line, which uses larger PSI engines starting at the 8.1L I-6; the smaller PS-prefix units (PS130-01 and below) use the PSI 8.8L V8.
The NG150-01 ships standard with the DSE DCP7310 digital control panel. Key features include digital metering, engine and generator protection, CAN Bus J1939 ECU communications, Windows-based configuration software, RS485 interface, 8 programmable inputs, 10 contact outputs, and IP 65 ingress protection rating.
The PSI 8.1LT inline-six is specific to the 150 kW tier of Blue Star's NG-prefix gaseous line. Its inline-six form factor is slightly longer than the V8 used in PS-prefix units but with simpler access to many service items. Spark plugs, ignition coils, charge-air cooler hoses, and oil/air filters are the primary service intervals. The DSE DCP7310 controller is consistent across the entire current Blue Star gaseous lineup, so field technicians familiar with any Blue Star unit can service the NG150-01 controls without additional training.
Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.
Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.
Estimate runtime on this tank
Fuel demand at 75% load
1,575,000 BTU/hr≈ 1575.0 cf/min @ 1,000 BTU/cf
On utility natural gas the runtime is generally unlimited provided the supply line and meter can deliver this BTU/hr at the engine's required inlet pressure (typically 5–14" WC residential, up to 5 psi commercial). Confirm against the OEM's published fuel-pressure spec.
Service intervals
Manufacturer-recommended intervals for the Blue Star NG150-01 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.
Oil & filter
Every 250 hours or 12 months
Coolant change
Every 4000 hours
Air filter
Every 1000 hours
Spark plugs
Every 1500 hours
Major overhaul
≈ 15,000 hours
Load bank test
Every 12 months
Common failure modes
What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.
Component
Symptom
Typical hours
Severity
Turbocharger
Loss of power, excessive smoke under load
12,000+
moderate
Spark plugs / ignition
Misfire at load, rough running
1,500+
minor
Charge air cooler
Reduced power output, elevated intake temps
10,000+
moderate
Battery
Failed to start during outage
8,760+
minor
Frequently Asked Questions
What is the standby rating of the NG150-01?
The Blue Star NG150-01 is rated 150 kWe standby on natural gas (115 kWe on LP) at 60 Hz / 1800 RPM per the OEM spec sheet. The PSI 8.1LT engine produces 236 bHp (176 kWm) at standby. The prime-rated variant is the NG150-01P at 125 kWe on natural gas.
What engine powers the NG150-01?
The PSI 8.1LT — an 8.1-liter inline-six turbocharged-aftercooled spark-ignition engine rated 236 bHp (176 kWm) at 1800 RPM standby. Bore is 4.37 in (11.1 cm), stroke is 5.47 in (13.9 cm), compression ratio 10.5:1. It is EPA certified for emergency standby under 40 CFR 60 Subpart JJJJ.
What controller does the NG150-01 use?
The DSE DCP7310 digital control panel — microprocessor-based with CAN Bus (J1939) ECU communications, 8 programmable contact inputs, 10 contact outputs, RS485 interface, IP 65 rating, and NFPA 110 Level 1 compatibility. The DCP7310 is standard across Blue Star's current gaseous product line.
Can the NG150-01 run on LP propane?
Yes. The NG150-01 supports both natural gas and LP propane. The LP standby rating is 115 kWe. Required fuel inlet pressure is 11 in. water column for both fuels; fuel inlet is 1.5-inch NPT.
What are the dimensions and weight of the NG150-01?
The open power unit (OPU) measures 110 x 60 x 66 in (L x W x H) and weighs 5,225 lbs. Level 1 and 2 enclosed configurations are 134 x 60 x 80 in at 6,150 and 6,225 lbs respectively. The Level 3 sound-attenuated enclosure is 174 x 60 x 80 in at 6,500 lbs. Sound level at the OPU is 82 dBA full load at 23 ft (7 m).
150 kW standby · Natural Gas / LPG · Liquid-cooled
125 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 8.1LT inline-six, DSE DCP7310 controller, 208-600V, continuous prime duty.
150 kW standby · Natural Gas / LPG · Liquid-cooled
150 kW natural gas / LP standby generator from Blue Star Power Systems. PSI 8.8LTCAC turbocharged-aftercooled V8, DSE DCP7310 controller, single- and three-phase 120-600V.
100 kW standby · Natural Gas / LPG · Liquid-cooled
100 kW natural gas standby generator (80 kW on LP) from Blue Star Power Systems. PSI 5.7LTCAC turbocharged charge-air-cooled V8, Stamford UCI274C alternator, DSE DCP7310 controller, 208-600V output.
200 kW standby · Natural Gas / LPG · Liquid-cooled
175 kW prime-rated natural gas / LP generator from Blue Star Power Systems. PSI 11.1L inline-six, DSE DCP7310 controller, 208-600V, continuous prime duty.