Triton Power

Triton Power TP-P200-T3-UL

200 kW standby / 180 kW prime · Diesel · Liquid-cooled

200 kW Tier 3 diesel generator with Perkins 1106D-E70TAG5 engine. UL2200-listed for commercial, healthcare, and government standby.

Standby power
200 kW / 180 kW prime
Voltage options
120/240V, 120/208V, 277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Perkins 1106D-E70TAG5 · 7.01L
EPA / Emissions
Tier 3
Alternator
Leroy Somer TAL044

Overview#

The Triton Power TP-P200-T3-UL is a 200 kW diesel standby generator built on the Perkins 1106D-E70TAG5 turbocharged and aftercooled six-cylinder engine (7.01 L displacement) with a Leroy Somer TAL044 alternator. It carries UL2200 listing and meets EPA Tier 3 for emergency stationary applications. This is a three-phase-only unit available at 277/480V, 120/208V, and 120/240V.

The TAG5 variant of the Perkins 1106D extracts 200 kW standby from the same 7.01 L block used in Triton's 150 kW model, representing the top of that engine platform's output range. Fuel consumption is 54.5 L/hr (14.4 GPH) at full load, dropping to 29.5 L/hr (7.8 GPH) at half load.

Our service experience#

The 200 kW class is a critical sizing threshold for commercial standby — it covers most mid-rise office buildings, large retail centers, and community healthcare facilities. The Perkins 1106D platform at this output level competes with the Cummins 6BTAA5.9 and John Deere 6068H-based generators. In our Northern California territory, the competitive pricing on Triton's Perkins-powered units makes them an attractive alternative when the Perkins dealer network provides adequate local support.

Engineering specifications

Fuel system & runtime

Fuel use @ full load
14.4 GPH
Fuel use @ 75% load
11.5 GPH
Fuel use @ 50% load
7.8 GPH

Ready to order this model?

Configure your Triton Power TP-P200-T3-UL

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Triton Power TP-P200-T3-UL

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

18.0 hours(0.8 days)

Fuel consumption ≈ 11.11 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Similar models

Triton Power

Triton Power TP-P150-T3-UL

150 kW standby · Diesel · Liquid-cooled

150 kW Tier 3 diesel generator with Perkins 1106D-E70TAG2 engine. UL2200-listed for commercial, healthcare, and institutional standby.

Tier 33-phasecommercial-standbyhealthcare

Triton Power

Triton Power TP-F250-T3-UL

260 kW standby · Diesel · Liquid-cooled

260 kW Tier 3 diesel generator with FPT C87TE3F.F550 engine. UL2200-listed for commercial and industrial standby applications.

Tier 33-phasecommercial-standbyhealthcare

Triton Power

Triton Power TP-P100-T3-UL

100 kW standby · Diesel · Liquid-cooled

100 kW Tier 3 diesel generator with Perkins 1104D-E44TAG2 engine. UL2200-listed for commercial and institutional standby applications.

Tier 33-phasecommercial-standbyhealthcare

Need service or parts for the Triton Power TP-P200-T3-UL?

We service every major OEM and stock genuine parts for the most common models.