Olympian

Olympian GEP88

88 kW standby · Diesel · Liquid-cooled

Olympian GEP88: 88 kW diesel generator powered by the Perkins 1104A-44TAG2 engine. Turbocharged-aftercooled 4.4L inline-4 for commercial standby.

Standby power
88 kW
Voltage options
277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Perkins 1104A-44TAG2 · 4.4L

Overview#

The Olympian GEP88 is an 88 kW diesel generator powered by the Perkins 1104A-44TAG2 — a 4.4-liter turbocharged-aftercooled inline-4 engine. The aftercooler is the key differentiator from the GEP65's turbocharged-only engine, providing cooler, denser intake air for higher power output from the same 4.4-liter displacement. The GEP88 delivers three-phase 277/480V power at 60 Hz for commercial standby applications.

The 88 kW rating positions the GEP88 in the mid-range commercial standby market, serving medium-size office buildings, multi-tenant retail, light manufacturing facilities, and institutional buildings. This power class covers buildings with moderate HVAC loads, elevators, and essential circuits without stepping up to the larger 6-cylinder engines required for 100+ kW applications.

The Perkins 1104A platform's turbocharged-aftercooled configuration has been extensively deployed across generator, construction, and industrial equipment applications worldwide. The GEP88 benefits from this global parts ecosystem and is serviced through the Caterpillar dealer network as part of the Olympian value-tier product line. For operators already running Olympian or Perkins-powered equipment, the GEP88 offers parts commonality with the GEP65 and GEP110, simplifying spare parts inventory management across multiple sites.

Ready to order this model?

Configure your Olympian GEP88

Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.

Estimate runtime for the Olympian GEP88

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

42.1 hours(1.8 days)

Fuel consumption ≈ 4.75 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Olympian GEP88 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Coolant change
Every 6000 hours
Air filter
Every 1000 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours
Load bank test
Every 12 months

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
Fuel quality / tank contaminationHard starting, filter clogging, injector fouling4,380+moderate
BatteryFailed to start, slow crank8,760+minor
Coolant hosesSlow coolant loss, weeping at clamps8,000+minor

Frequently Asked Questions

What is the difference between the GEP65 and GEP88?
Both use the same 4.4-liter Perkins 1104A engine block. The GEP88 adds an aftercooler (turbocharged-aftercooled vs turbocharged-only), providing cooler, denser intake air for higher power output — 88 kW versus 65 kW from the same displacement. Many service parts are interchangeable.
What is the oil change interval on the Olympian GEP88?
The GEP88 requires oil and filter changes every 500 hours or 12 months, whichever comes first. Air filters at 1,000 hours, fuel filters at 500 hours, and coolant every 6,000 hours or 5 years.

More in the Olympian GEP Series (Diesel)

Olympian GEP diesel generators — 15–500 kW value-tier units with Perkins engines, backed by the Caterpillar dealer network.

Similar models

Olympian

Olympian GEP65

65 kW standby · Diesel · Liquid-cooled

Olympian GEP65: 65 kW diesel generator powered by the Perkins 1104A-44TG1 engine. 4.4L inline-4 for commercial standby applications.

3-phasecommercial-standby

Olympian

Olympian GEP22

22 kW standby · Diesel · Liquid-cooled

Olympian GEP22: 22 kW diesel generator powered by the Perkins 404A-22G1 engine. Compact 2.2L inline-4 for light commercial standby applications.

3-phasecommercial-standby
Doosan / Bobcat Doosan G100 88 kW liquid-cooled standby generator

Doosan / Bobcat

Doosan G100

First Cummins-powered Doosan — Stamford alternator and Cummins F3.8 engine deliver premium-grade components at 15-30% below MQ Power/Airman pricing.

88 kW standby · Diesel · Liquid-cooled

80 kW prime diesel portable generator. Cummins F3.8-powered with 67 dBA operation, Stamford alternator, and dual-frequency switching.

Tier 4 Final3-phaseconstructionrental-fleet

Need service or parts for the Olympian GEP88?

We service every major OEM and stock genuine parts for the most common models.