Hipower Systems · HFW Series (Stationary Diesel)

Hipower HFW-100

100 kW standby · Diesel · Liquid-cooled

100 kW standby diesel generator with FPT N67 inline-6 engine and Stamford alternator. EPA Tier 4 Final. US manufactured in Olathe, Kansas.

Hipower Systems Hipower HFW-100 generator — specifications and details
Standby power
100 kW
Voltage options
120/240V, 120/208V, 277/480V
Frequency / Phase
60 Hz · 1/3-phase
Engine
FPT Industrial N67 · 6.7L
EPA / Emissions
Tier 4 Final
Alternator
Stamford UCI274

Overview#

The Hipower HFW-100 is a 100 kW stationary standby diesel generator powered by the FPT Industrial N67 inline-6 engine and a Stamford alternator. Manufactured at Hipower's 515,000 sq ft facility in Olathe, Kansas, the HFW-100 carries EPA Tier 4 Final certification and is designed for demanding commercial standby applications — office buildings, supermarkets, urgent care centers, and telecom infrastructure where 100 kW of reliable backup power is paired with strict emissions compliance. The N67 engine represents a step up in displacement and cylinder count from the N45-powered HFW-60 and HFW-80, delivering increased torque reserve at this output level.

FPT Industrial Engine Platform#

The N67 is a 6.7-liter turbocharged inline-6 diesel produced by FPT Industrial, the power generation and industrial engine arm of CNH Industrial. The N67 shares its core architecture with engines powering Case IH and New Holland tractors — one of the most widely deployed inline-6 diesel platforms in North American agriculture. This translates to a parts and service ecosystem that extends far beyond the generator market into agricultural dealers across California.

At 100 kW standby output, the N67 operates at 1800 RPM for 60 Hz generation with substantial torque reserve, which contributes to stable frequency regulation during motor starting events. Tier 4 Final compliance for the N67 family typically involves a combination of SCR aftertreatment for NOx reduction and a diesel particulate filter — a factory-engineered emissions system that satisfies both EPA certification and California CARB requirements without requiring operator-modified configurations.

FPT's California presence is amplified by the CNH dealer network spanning from the Sacramento Valley to the Salinas Valley, with dealer locations stocking N67-family consumables and maintaining FPT-certified diagnostic equipment.

Hipower Design Advantages#

Hipower builds the HFW-100 to NFPA 110 Level I/II compliance, covering life-safety and optional standby classifications. Single-phase availability (120/240V and 120/208V) in addition to three-phase 277/480V makes the HFW-100 suitable for a broad range of commercial electrical configurations, including older commercial buildings with single-phase distribution.

The DSE digital controller handles automatic start sequencing, transfer switch coordination, and multi-fault protection. Optional paralleling capability (via DSE8610 controller upgrade) allows two or more HFW-100 units to share load in critical installations. Hipower's in-house enclosure and fuel system integration simplifies permit submittal packages for NFPA 110, UL 2200, and seismic (IBC) requirements.

Service and Maintenance#

The FPT N67's 500-hour oil change interval under standby duty is consistent with FPT's published maintenance schedule for this engine family. The 12-month calendar trigger is typically the operational driver for commercial standby units that accumulate fewer running hours annually.

At 100 kW, fuel quality management becomes increasingly important. The N67's common-rail fuel system is sensitive to water contamination and microbial growth in diesel that sits in the tank for extended periods. Annual fuel polishing is strongly recommended — especially for Bay Area coastal installations where temperature cycling accelerates condensation in the fuel tank. A fuel biocide program extends injector service intervals and reduces the risk of unplanned service calls.

Stamford UCI274-family alternators are field-proven at this output class. Annual service items include insulation resistance testing, connection torque verification, and inspection for bearing wear.

Our Service Experience#

OnPoint Generators services HFW-100 units across the Bay Area and Northern California. The FPT N67 parts supply through CNH's Case/New Holland dealer network keeps filter and injector lead times short for our field teams. EPA Tier 4 Final certification makes new installations straightforward from a permit perspective, and OnPoint supports ATC and permit-to-operate documentation for California commercial projects.

Request a quote

Get pricing & lead time on the Hipower HFW-100

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Hipower HFW-100

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

37.0 hours(1.5 days)

Fuel consumption ≈ 5.40 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Hipower HFW-100 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours or 12 months
Air filter
Every 500 hours
Fuel filter
Every 500 hours
Major overhaul
20,000 hours

Common failure modes

What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.

ComponentSymptomTypical hoursSeverity
FPT fuel injectorsCombustion roughness and smoke at high loads — clean or replace at 10,000 hours10,000+moderate
Coolant systemFreeze plug corrosion in extended standby — inspect during annual service8,760+minor
Starting batteryCapacity loss in standby — float charge and test annually4,380+minor

Frequently Asked Questions

What is the standby vs prime power rating of the HFW-100?
The HFW-100 is rated 100 kW standby. Prime power ratings are not published separately by Hipower for the HFW series — contact OnPoint for application-specific load analysis.
What engine does the HFW-100 use?
The HFW-100 uses an FPT Industrial N67 engine — a 6.7-liter turbocharged inline-6 diesel produced by CNH Industrial's FPT division. The N67 is the same engine family used in Case IH and New Holland tractors and is one of FPT's most widely deployed inline-6 platforms.
Is the HFW-100 EPA Tier 4 Final compliant for California?
Yes. The HFW series is current production certified to EPA Tier 4 Final. This meets CARB requirements for new stationary diesel standby generators in California, including installations in SCAQMD, BAAQMD, and SJVAPCD jurisdictions.
What are the service intervals for the HFW-100?
The FPT N67 calls for oil changes every 500 hours or 12 months. Air and fuel filter service also at 500-hour intervals. The N67 engine family supports 20,000-hour major overhaul intervals in standby applications.
How does the HFW-100 compare to a Generac or Kohler at 100 kW?
The HFW-100 competes with offerings like the Generac SG100 or Kohler 100REOZJF. The FPT N67 inline-6 is a heavier-duty commercial diesel platform than some competitors' engines at this kW class, with broader dealer parts coverage through the Case/New Holland agricultural network across California.
Who services HFW generators in Northern California?
OnPoint Generators services HFW units across the Bay Area and NorCal. FPT N67 parts are available through Case/New Holland dealers and FPT's own service network throughout California.
What controller does the HFW-100 use?
The HFW-100 comes with a DSE (Deep Sea Electronics) controller as standard — typically DSE 7410 or equivalent — with automatic start/stop, fault shutdown protection, and optional remote monitoring expansion.

Similar models

Hipower Systems Hipower HRJW-125 100 kW liquid-cooled standby generator

Hipower Systems

Hipower HRJW-125

100 kW standby · Diesel · Liquid-cooled

100 kW rental-ready trailer-mounted diesel generator. John Deere 4045HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.

3-phaserental-fleetconstruction
Hipower Systems Hipower HJW-105 105 kW liquid-cooled standby generator

Hipower Systems

Hipower HJW-105

105 kW standby · Diesel · Liquid-cooled

105 kW diesel standby generator. John Deere 4045HF285 family engine, Stamford UCI 274 alternator. EPA Tier 3. US manufactured in Olathe, Kansas.

Tier 33-phasecommercial-standbylight-commercial
Hipower Systems Hipower HRJW-145 116 kW liquid-cooled standby generator

Hipower Systems

Hipower HRJW-145

116 kW standby · Diesel · Liquid-cooled

116 kW rental-ready trailer-mounted diesel generator. John Deere 4045HF285-family engine. Towable, lockable enclosure. Built in Olathe, Kansas.

3-phaserental-fleetconstruction

Need service or parts for the Hipower HFW-100?

We service every major OEM and stock genuine parts for the most common models.