Hipower Systems · HDI Series

Hipower HDI-1250

1250 kW standby · Diesel · Liquid-cooled

1250 kW standby diesel generator with Mitsubishi engine. Heavy-duty industrial large-frame series.

Hipower Systems Hipower HDI-1250 generator — specifications and details
Standby power
1250 kW
Voltage options
277/480V
Frequency / Phase
60 Hz · 3-phase
Engine
Mitsubishi Heavy Industries S12R-Y2PTAW-1
EPA / Emissions
Tier 2
Alternator
Stamford S7L1D

Overview#

The Hipower HDI-1250 is a 1250 kW standby diesel generator powered by a Mitsubishi 12-cylinder turbocharged intercooled engine. Manufactured in Olathe, Kansas with NFPA 110 Level 1 certification and redundant starting.

Engineering specifications

Acoustic

Sound @ 7m, full load
81 dBA
Enclosure
Sound-attenuated

Fuel system & runtime

Fuel use @ full load
97 GPH

Request a quote

Get pricing & lead time on the Hipower HDI-1250

Tell us about the application — kW, voltage, application, install timeline — and we'll respond within one business day with budgetary pricing, lead time, and any sizing notes.

Estimate runtime for the Hipower HDI-1250

Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.

Estimate runtime on this tank

Estimated runtime

2.7 hours(0.1 days)

Fuel consumption ≈ 74.83 GPH at 75% load. Estimate based on industry-typical 1800 RPM standby curves (≈0.07 GPH/kW at full load). Actual consumption varies by engine, ambient temperature, fuel quality, and tuning.

Service intervals

Manufacturer-recommended intervals for the Hipower HDI-1250 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.

Oil & filter
Every 500 hours
Air filter
Every 500 hours
Fuel filter
Every 500 hours
Major overhaul
2,000 hours

Frequently Asked Questions

What is the standby rating of the Hipower HDI-1250?
The HDI-1250 is rated at 1250 kW standby at 277/480V, three-phase, 60 Hz. NFPA 110 Level 1 certified, it is engineered for Tier 3+ data centers, large hospitals, and industrial facilities requiring large-frame megawatt emergency power.
What engine powers the Hipower HDI-1250?
The HDI-1250 is powered by a Mitsubishi Heavy Industries S12R-Y2PTAW-1 12-cylinder turbocharged-aftercooled diesel engine with a Stamford S7L1D alternator. The S12R is the higher-displacement Mitsubishi large-frame platform, providing the torque and reliability needed at 1250 kW standby.
What are the service intervals for the HDI-1250?
Oil changes, air filter replacements, and fuel filter replacements are due every 500 hours. Major overhaul is at 2,000 hours, per Mitsubishi Heavy Industries S12R series published maintenance requirements.
How does the HDI-1250 compare to Cat, Cummins, or Kohler at 1250 kW?
The HDI-1250 competes with Cat C32 and Cummins QSK38 standby sets at the 1250 kW class, matching NFPA 110 L1, seismic, and 200 mph wind certifications at 15-25% lower list price. Mitsubishi's S12R engine is a globally respected industrial platform with strong parts availability.
Is the HDI-1250 NFPA 110 Level 1 compliant?
Yes. The HDI-1250 is NFPA 110 Level 1 certified with redundant starting systems, seismic rating, and 200 mph wind certification, qualifying it for the most demanding mission-critical standby applications.
Who services Hipower HDI generators in Northern California?
OnPoint Generators is an authorized Hipower dealer and service provider serving the Bay Area and Northern California. We offer HDI-1250 sales, commissioning, load bank testing, and preventive maintenance for large-frame installations.

More in the HDI Series

60 to 2,000 kW industrial diesel standby across FPT, Volvo, and Mitsubishi platforms — data-center spec at 15–25% below Big 4 pricing.

Similar models

Hipower Systems Hipower HRVW-1375 1.2 MW liquid-cooled standby generator

Hipower Systems

Hipower HRVW-1375

Flagship mobile diesel power — 1,210 kW standby, Volvo TWD engine, Tier 4 Final, for mission-critical and large-scale rental deployment.

1.2 MW standby · Diesel · Liquid-cooled

1375 kVA (1210 kW standby) mobile diesel generator with Volvo TWD-family engine. Tier 4 Final. Flagship mobile unit — over 1.2 MW of standby power.

Tier 4 Final3-phaseconstructionrental-fleet
Hipower Systems Hipower HMW-1205 1.2 MW liquid-cooled standby generator

Hipower Systems

Hipower HMW-1205

MTU 16V2000 at 1,205 kW — top of the 2000 series before entering the 4000 series. Maximum output for a single 16V2000 unit with 30,000-hour TBO.

1.2 MW standby · Diesel · Liquid-cooled

1205 kW MTU 2000-series diesel generator. NFPA 110 Level 1, seismic certified, 200 mph wind rated. US manufactured in Olathe, Kansas.

Tier 23-phaseindustrial-standbydata-center
Hipower Systems Hipower HRVW-1250 1.1 MW liquid-cooled standby generator

Hipower Systems

Hipower HRVW-1250

Over 1 MW of mobile diesel power — Volvo TWD-powered, Tier 4 Final, for data centers, substations, and major construction.

1.1 MW standby · Diesel · Liquid-cooled

1250 kVA (1088 kW standby) mobile diesel generator with Volvo TWD1644GE family engine. Tier 4 Final. Over 1 MW of mobile standby power.

Tier 4 Final3-phaseconstructionrental-fleet

Need service or parts for the Hipower HDI-1250?

We service every major OEM and stock genuine parts for the most common models.